회로 보호 제품

홈제품회로 보호 제품RCBORCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole
  • RCBO 잔류 전류 차단기, 과전류 및 누설 보호 기능, 차동 차단기 JCB2LE-80M 2극
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3
  • RCBO 잔류 전류 차단기, 과전류 및 누설 보호 기능, 차동 차단기 JCB2LE-80M 2극
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3

RCBO 잔류 전류 차단기, 과전류 및 누설 보호 기능, 차동 차단기 JCB2LE-80M 2극

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards. Request the required configuration and matching installation documents from W9 Group.

기술 데이터

JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards.

JCB2LE-80M specifications
표준 IEC61009-1 , EN61009-1
정격 전류(A) 6, 10, 16, 20, 25, 32, 40,50,63,80
형태 전자적
Type (wave form of the earth leakage sensed) A or AC are available
폴란드인 2 Pole
Rated voltage Ue(V) 230/240
Rated sensitivity I△n 30mA,100mA,300mA are available
절연 전압 Ui(V) 500
정격 주파수 50/60Hz
최대 절단 용량 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
오염 정도 2
열 자성 방출 특성 B, C
전기 수명 2, 000
기계적 수명 10, 000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperature (℃) -25…+70
터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2 / 18-3 AWG
버스바용 터미널 사이즈 상단/하단 10mm2 / 18-8 AWG
강력한 토크 2.5 N*m / 22 In-Ibs.
장착 On DIN rail EN 60715 (35mm) by means of fast clip device
연결 상단 또는 하단에서 사용할 수 있습니다.

선정 가이드

Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits

Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.

01

Select the rated current

The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.

02

Specify leakage protection

Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.

03

Identify the breaking rating

Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.

04

Check board connections

The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.

Before specifying JCB2LE-80M: Match rated current, trip curve, residual-current sensitivity and detection type to the circuit requirements. Use the wiring diagram for the selected configuration.

W9 그룹 소개

W9 Group 2 Pole Electronic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.

구매자 FAQ

RCBO FAQs: Trip Curves and Leakage Sensitivity

Find answers about ratings, configuration and ordering.

Is JCB2LE-80M a 2 pole RCBO?

The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.

Is the standard breaking capacity 6 kA or 10 kA?

The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.

Can I specify JCB2LE-80M as a 16 A RCBO?

The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.

What is needed for a JCB2LE-80M quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.