회로 보호 제품

홈제품회로 보호 제품RCBORCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA
  • RCBO 단일 모듈 잔류 전류 차단기, 과부하 보호 기능 JCB2LE-40M 1P+N 미니 6kA
  • RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA Gallery image 2
  • RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA Gallery image 3
  • RCBO 단일 모듈 잔류 전류 차단기, 과부하 보호 기능 JCB2LE-40M 1P+N 미니 6kA
  • RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA Gallery image 2
  • RCBO single Module residual current circuit breaker with overload protection JCB2LE-40M 1P+N mini 6kA Gallery image 3

RCBO 단일 모듈 과부하 보호 기능이 있는 잔류 전류 차단기 JCB2LE-40M 1P+N 미니 6kA

The JCB2LE-40M single module RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

기술 데이터

JCB2LE-40M 6kA 1P+N Single Module RCBO Specifications

The JCB2LE-40M single module RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

표준

IEC61009-1 ,  EN61009-1

Electrical

features

정격 전류(A)

6, 10, 16, 20, 25, 32, 40

형태

전자적

형태(지하 배수관에서 감지된 파형)

A or AC are available

폴란드인

1P+N

정격 전압 Ue(V)

230/240

Rated sensitivity I△n

30mA, 100mA,300mA

절연 전압 Ui(V)

500

정격 주파수

50/60Hz

최대 절단 용량

6kA

정격 임펄스 내전압(1.2/50) Uimp (V)

6000

오염 정도

2

열 자성 방출 특성

B, C

Mechanical

features

전기 수명

2, 000

기계적 수명

20, 000

접촉 위치 표시기

네

보호 수준

IP20

열체 열 설정 기준 온도(℃)

30

Ambient temperature (with daily average ≤35℃)

-5…+40

Storage temperation (℃)

-25…+70

설치

터미널 연결 유형

Cable/Pin-type busbar

케이블의 상단/하단 터미널 사이즈

16mm2  / 18-5 AWG

버스바용 터미널 사이즈 상단/하단

10mm2  / 18-8 AWG

강력한 토크

2.5 N*m  /  22 In-Ibs.

장착

DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착

연결

상단 또는 하단에서 사용할 수 있습니다.

선정 가이드

Selecting a 30mA or 100mA RCBO for a DIN Rail Consumer Unit

Specify the rated current, B or C curve, waveform type, residual-current sensitivity, module dimensions and busbar requirements when requesting a JCB2LE-40M quotation from W9 Group.

01

Check module space

JCB2LE-40M is listed as a single-module 1P+N RCBO. Confirm dimensions and busbar fit for the selected enclosure.

02

Choose current and curve

Current options from 6 to 40 A and B or C curves are listed. State both fields in the enquiry.

03

Choose leakage detection

Specify Type A or Type AC and the required 30 mA or 100 mA sensitivity. Confirm the selected combination.

04

Check connections

Request the cable, busbar and terminal instructions for the selected unit before installation.

Before specifying JCB2LE-40M: Confirm the selected current, curve, waveform and sensitivity on the quotation. Request the JCB2LE-40M dimensions, terminal diagram and installation instructions for the planned distribution board.

W9 그룹 소개

W9 Group 1P+N Single Module RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-40M order, contact W9 Group about the required configuration and product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCB2LE-40M 1P+N Single Module RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-40M configuration.

구매자 FAQ

RCBO FAQs: Module Width, Current and Sensitivity

Find answers about configuration, installation documents and ordering.

What pole arrangement does JCB2LE-40M use?

JCB2LE-40M is listed as a single-module 1P+N RCBO. Confirm live and neutral terminal identification using its wiring diagram.

Which sensitivity options are shown here?

This page lists 30 mA and 100 mA sensitivity options. Ask W9 Group to confirm the required sensitivity and waveform combination for the quoted device.

Which current ratings and trip curves are listed?

JCB2LE-40M lists 6, 10, 16, 20, 25, 32 and 40 A ratings with B or C curves. Confirm the chosen rating and curve on the quotation.

What is needed for a JCB2LE-40M quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

How do I choose Type A or Type AC for JCB2LE-40M?

Specify the residual-current waveform response required by the load and installation design. Ask W9 Group to confirm the available JCB2LE-40M version and its matching test and wiring documents.

Which JCB2LE-40M busbar and terminal details should I confirm?

Request the selected JCB2LE-40M terminal drawing and confirm the compatible busbar form, conductor connection and tightening instructions before arranging the consumer unit.

How do I check JCB2LE-40M against upstream protective devices?

Provide the installation voltage and prospective fault current, and request the applicable breaking-capacity and coordination data. Confirm the selected current and trip-curve version as part of that check.

제품 문의

Request a JCB2LE-40M 1P+N Single Module RCBO Quotation

Tell W9 Group your rated current, B or C curve, waveform type, residual-current sensitivity, module dimensions and busbar requirements, quantity and destination market so the selected configuration can be identified.