회로 보호 제품

홈제품회로 보호 제품RCBORCBO JCB1LE-125 125A 6kA
  • RCBO JCB1LE-125 125A 6kA 갤러리 이미지 1
  • RCBO JCB1LE-125 125A 6kA Gallery image 2
  • RCBO JCB1LE-125 125A 6kA Gallery image 3
  • RCBO JCB1LE-125 125A 6kA Gallery image 4
  • RCBO JCB1LE-125 125A 6kA 갤러리 이미지 1
  • RCBO JCB1LE-125 125A 6kA Gallery image 2
  • RCBO JCB1LE-125 125A 6kA Gallery image 3
  • RCBO JCB1LE-125 125A 6kA Gallery image 4

RCBO JCB1LE-125 125A 6kA

W9 Group lists JCB1LE-125 as an electronic RCBO series for residual-current, overload and short-circuit protection in distribution boards. Select the rated current and pole configuration for the circuit.

기술 데이터

JCB1LE-125 63–125A RCBO Specifications

W9 Group lists JCB1LE-125 as an electronic RCBO series for residual-current, overload and short-circuit protection in distribution boards. Select the rated current and pole configuration for the circuit.

표준

IEC61009-1 ,  EN61009-1

Electrical

features

정격 전류(A)

63,80,100,125

형태

전자적

형태(지하 배수관에서 감지된 파형)

A or AC are available

폴란드인

1 pole, 2 Pole, 3 pole, 4 pole

정격 전압 Ue(V)

230/240

Rated sensitivity I△n

30mA,100mA,300mA

절연 전압 Ui(V)

500

정격 주파수

50/60Hz

최대 절단 용량

6kA

정격 임펄스 내전압(1.2/50) Uimp (V)

6000

오염 정도

2

열 자성 방출 특성

B, C

Mechanical

features

전기 수명

2, 000

기계적 수명

2, 000

접촉 위치 표시기

네

보호 수준

IP20

열체 열 설정 기준 온도(℃)

30

Ambient temperature (with daily average ≤35℃)

-5…+40

Storage temperation (℃)

-25…+70

설치

터미널 연결 유형

Cable/Pin-type busbar

케이블의 상단/하단 터미널 사이즈

16~50/6-1/0 AWG

버스바용 터미널 사이즈 상단/하단

16~35mm2  / 6-2 AWG

강력한 토크

3.5 N*m  /  31 In-Ibs.

장착

DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착

연결

상단 또는 하단에서 사용할 수 있습니다.

선정 가이드

Selecting a 63A, 80A, 100A or 125A RCBO by Pole Arrangement

Specify the rated current, pole configuration, supply voltage, waveform type, residual-current sensitivity and cable or busbar arrangement when requesting a JCB1LE-125 quotation from W9 Group.

01

Choose the current variant

The technical table lists 63, 80, 100 and 125 A. Include the exact rated current and load information in the enquiry.

02

Specify the pole configuration

The series lists one-, two-, three- and four-pole options. Request the wiring diagram and voltage rating of the selected configuration.

03

Match leakage detection

The table lists Type A or Type AC, 30 mA, 100 mA and 300 mA sensitivities, and B or C curves. Confirm the required combination.

04

Check cable and busbar fit

Check cable capacity, busbar connection and tightening torque in the JCB1LE-125 installation document.

Before specifying JCB1LE-125: Confirm the operating voltage for the selected pole configuration before ordering. Request model-specific compliance documents when required by the destination market.

W9 그룹 소개

W9 Group 125A RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB1LE-125 order, contact W9 Group about the required configuration and product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCB1LE-125 125A RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB1LE-125 configuration.

구매자 FAQ

RCBO FAQs: Pole Options, Voltage and Trip Curves

Find answers about ratings, configuration and ordering.

Is a 63 A RCBO listed in the JCB1LE-125 series?

Yes. The JCB1LE-125 current schedule lists 63, 80, 100 and 125 A. For a 63 A RCBO, specify the pole configuration, operating voltage and residual-current settings. Confirm the exact combination on the quotation.

Which pole configurations are listed?

The JCB1LE-125 series lists one-, two-, three- and four-pole configurations. Select the arrangement required by the circuit and confirm its voltage rating and wiring diagram.

What is the short-circuit breaking capacity?

W9 Group lists a 6 kA breaking capacity for JCB1LE-125. Check the selected device's rating documents against the circuit requirements.

What is needed for a JCB1LE-125 quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

Which JCB1LE-125 trip-curve documents should I request?

Request the time-current curve for the exact JCB1LE-125 current and trip-curve selection. Check it against the load starting behavior and upstream protection rather than using the series name alone.

How do I confirm phase and neutral wiring for JCB1LE-125?

Request the connection diagram for the selected pole arrangement and confirm the supply and neutral terminal assignments. Use the matching installation instructions for that order code.

What panel-fit details matter for a JCB1LE-125 RCBO?

Request the outline drawing, terminal-space requirements and connection instructions for the selected JCB1LE-125. Confirm the busbar and conductor arrangement against the board design.

제품 문의

Request a JCB1LE-125 125A RCBO Quotation

Tell W9 Group your rated current, pole configuration, supply voltage, waveform type, residual-current sensitivity and cable or busbar arrangement, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기