RCBO JCB1LE-125 125A 6kA

W9 Group lists JCB1LE-125 as an electronic RCBO series for residual-current, overload and short-circuit protection in distribution boards. Select the rated current and pole configuration for the circuit. Request the required configuration and matching installation documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB1LE-125 63–125A RCBO Specifications

W9 Group lists JCB1LE-125 as an electronic RCBO series for residual-current, overload and short-circuit protection in distribution boards. Select the rated current and pole configuration for the circuit.

JCB1LE-125 specifications
Стандартный IEC61009-1 , EN61009-1
Максимальный ток в А (А) 63,80,100,125
Тип Электронный
Type (wave form of the earth leakage sensed) A or AC are available
Поляки 1 pole, 2 Pole, 3 pole, 4 pole
Rated voltage Ue(V) 230/240 listed; confirm the operating voltage for the selected pole configuration.
Rated sensitivity I△n 30mA,100mA,300mA
Изоляционное напряжение Ui (В) 500
Определенная частота 50/60 Гц
Максимальный пробойной прочность 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Уровень загрязнения 2
Характеристика термомагнитного разрыва B, C
Электрическая жизнь 2, 000
Механический срок службы 2, 000
Индикатор положения контакта Да
Степень защиты IP20
Reference temperature for setting of thermal element(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperature (℃) -25…+70
Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 16~50/6-1/0 AWG
Terminal size top/bottom for Busbar 16~35mm2 / 6-2 AWG
Усиление крутящего момента 3.5 N*m / 31 In-Ibs.
Установка On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top or bottom are available

ГИД ПО ОТБЕРЕЖЕ

Selecting a 63A, 80A, 100A or 125A RCBO by Pole Arrangement

Specify the rated current, pole configuration, supply voltage, waveform type, residual-current sensitivity and cable or busbar arrangement when requesting a JCB1LE-125 quotation from W9 Group.

01

Choose the current variant

The technical table lists 63, 80, 100 and 125 A. Include the exact rated current and load information in the enquiry.

02

Specify the pole configuration

The series lists one-, two-, three- and four-pole options. Request the wiring diagram and voltage rating of the selected configuration.

03

Match leakage detection

The table lists Type A or Type AC, 30 mA, 100 mA and 300 mA sensitivities, and B or C curves. Confirm the required combination.

04

Check cable and busbar fit

Check cable capacity, busbar connection and tightening torque in the JCB1LE-125 installation document.

Before specifying JCB1LE-125: Confirm the operating voltage for the selected pole configuration before ordering. Request model-specific compliance documents when required by the destination market.

О W9 GROUP

W9 Group 125A RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB1LE-125 order, contact W9 Group about the required configuration and product documents.

Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB1LE-125 125A RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB1LE-125 configuration.

Часто задаваемые вопросы покупателей

RCBO FAQs: Pole Options, Voltage and Trip Curves

Find answers about ratings, configuration and ordering.

Is a 63 A RCBO listed in the JCB1LE-125 series?

Yes. The JCB1LE-125 current schedule lists 63, 80, 100 and 125 A. For a 63 A RCBO, specify the pole configuration, operating voltage and residual-current settings. Confirm the exact combination on the quotation.

Which pole configurations are listed?

The JCB1LE-125 series lists one-, two-, three- and four-pole configurations. Select the arrangement required by the circuit and confirm its voltage rating and wiring diagram.

What is the short-circuit breaking capacity?

W9 Group lists a 6 kA breaking capacity for JCB1LE-125. Check the selected device's rating documents against the circuit requirements.

What is needed for a JCB1LE-125 quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB1LE-125 125A RCBO Quotation

Tell W9 Group your rated current, pole configuration, supply voltage, waveform type, residual-current sensitivity and cable or busbar arrangement, quantity and destination market so the selected configuration can be identified.

Свяжитесь с W9 Group