Продукты для защиты от перегрузок

  • Резервный выключатель тока RCBO с защитой от перегрузки и утечки, диференциальный выключатель JCB2LE-EV с 2 полюсами
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3
  • Резервный выключатель тока RCBO с защитой от перегрузки и утечки, диференциальный выключатель JCB2LE-EV с 2 полюсами
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3

JCB2LE-EV 2 полюсный коммутатор с релевым выходом

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB2LE-EV 2 pole RCBO specifications

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval.

JCB2LE-EV product specifications
Модель JCB2LE-EV
Protection Residual current, overload and short circuit
Current options 32A / 40A
Residual-current response Type A
Sensitivity 30mA
Максимальный пробойной пропускной способностью 10kA
Trip curves B / C
Поляки 2 pole; neutral switched

ГИД ПО ОТБЕРЕЖЕ

JCB2LE-EV EV charging RCBO selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCB2LE-EV quotation from W9 Group.

01

Select load and overcurrent duty

Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.

02

Specify residual-current response

Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.

03

Check the EV protection arrangement

For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.

04

Confirm pole and terminal wiring

Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.

Before specifying JCB2LE-EV: Confirm operating voltage, charger DC protection, pole wiring and installation requirements for the exact offered RCBO.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB2LE-EV Type A residual current protection documents

Use technical support and related products to specify JCB2LE-EV. Request a datasheet and wiring diagram matching the selected JCB2LE-EV configuration.

Часто задаваемые вопросы покупателей

JCB2LE-EV two pole RCBO FAQs

Find answers about JCB2LE-EV selection, configuration and ordering.

Which protection functions are combined?

The summary identifies residual-current, overload and short-circuit protection in an electronic two-pole device. Confirm the complete ordered version.

Which current and curve options are listed?

W9 Group lists 32A and 40A, with B or C overcurrent characteristics. Select the curve using load starting behavior and the required conductor protection.

Does Type A mean smooth DC detection is included?

No smooth DC detection threshold is established by this target summary. Confirm the charger’s DC detection and the required upstream arrangement separately.

What residual-current sensitivity is listed?

The summary lists 30mA. Confirm the required sensitivity and exact protection arrangement against the charger instructions and installation rules.

Does this RCBO include open-PEN protection?

An independent open-PEN function is not established for the target product. Confirm any required separate protection instead of inferring it from the EV name.

Can the supply enter from either end?

The summary describes top and bottom wiring. Confirm the permitted supply terminals, neutral path and test-circuit operation from the matching installation drawing.

What is needed for a JCB2LE-EV quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB2LE-EV 2 pole RCBO quotation

Пожалуйста, сообщите компании W9 Group свой полный номер заказа, информацию о схеме подключения, условиях установки и необходимых документах, количество и место назначения рынка, чтобы можно было идентифицировать выбранную конфигурацию.

Свяжитесь с W9 Group