JC3LE-EV Тип EV 2 полюсный реле защиты от перегрузки 10KA

The W9 Group title identifies JC3LE-EV as a Type EV two-pole RCBO with a 10kA designation. For an enquiry, specify the load current, residual-current response and connection arrangement; confirm the actual breaking capacity and release design for the supplied version.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JC3LE-EV Two-Pole RCBO Product Information

The W9 Group title identifies JC3LE-EV as a Type EV two-pole RCBO with a 10kA designation. For an enquiry, specify the load current, residual-current response and connection arrangement; confirm the actual breaking capacity and release design for the supplied version.

The title states 10kA, while the retained original table states 6kA; the source descriptions also differ on the release design. Confirm these details on one datasheet matching the offered order code.

Код продукта JC3LE-EV
Стандартный IEC61009-1, EN61009-1
Электрические характеристики Максимальный ток в А (А) 6, 10, 16, 20, 25, 32, 40, 63
Тип Электронный
Тип (волны от утечки электроэнергии, обнаруженной на земле) А есть
Поляки 2полюсный
Номинальное напряжение Ue (В) 230/240
Определенная чувствительность IΔn 30 мА, 100 мА, 300 мА
Изоляционное напряжение Ui (В) 500
Определенная частота 50/60 Гц
Максимальный пробойной прочность 6KA
Определенная напряженность импульса (1,2/50) Uimp (В) 6,000
Теплопроводящий тест напряжения при индуктивном частотном режиме в течение 1 минуты (КВ) 2
Уровень загрязнения 2
Характеристика термомагнитного разрыва B, C
Механические характеристики Электрическая жизнь 2,000
Механический срок службы 10,000
Индикатор положения контакта Да
Степень защиты IP20
Референтная температура для настройки теплового элемента (℃) 30
Температура окружающей среды (с ежедневной средней температурой ≤35°C) -5…+40
Температура хранения (℃) -25…+70
Установка Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25 мм2/18-3AWG
Высокоскоростной терминал для разветвления кабелей 10 мм2/18-8AWG
Усиление крутящего момента 2,5 Н*м/22 ин-фунтов
Установка На DIN-рейле EN 60715 (35 мм)
Вставка Доступны варианты сверху или снизу

ГИД ПО ОТБЕРЕЖЕ

Selecting JC3LE-EV 2 pole RCBO for Your Installation

Use JC3LE-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Select load and overcurrent duty

Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.

02

Specify residual-current response

Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.

03

Check the EV protection arrangement

For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.

04

Confirm pole and terminal wiring

Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.

Before specifying JC3LE-EV: Confirm the release design, breaking capacity, waveform response and operating voltage for the complete order code.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

Request JC3LE-EV Two-Pole RCBO Wiring and Trip-Curve Data

Use technical support and related products to specify JC3LE-EV. Request a datasheet and wiring diagram matching the selected JC3LE-EV configuration.

Часто задаваемые вопросы покупателей

JC3LE-EV Two-Pole RCBO Ratings and Wiring FAQs

Find answers about JC3LE-EV selection, configuration and ordering.

Does this RCBO provide both leakage and overcurrent protection?

It is listed as an RCBO. Confirm the offered release, residual-current response, current option and fault rating using one matching datasheet.

Which breaking rating should I specify?

Request the current order-code rating schedule from W9 Group. Confirm the breaking capacity together with operating voltage and test standard before selecting the unit.

Is the release electronic or electromagnetic?

Confirm the release design for the exact quoted unit from its nameplate and technical documentation. Do not use a different version’s operating principle.

Which sensitivity should be selected?

Select the required sensitivity using the circuit design and the matching ordered configuration. Confirm the residual-current type and test-circuit instructions at the same time.

Does the EV name establish smooth DC detection?

A dedicated smooth DC detection function is not established for this exact target. Confirm the charger protection arrangement and any separate device required.

What must be confirmed for the two-pole connection?

Request the line, neutral, supply and load diagram, together with the test-circuit connection and permitted terminal orientation.

What should I send for a JC3LE-EV quotation?

Send the complete JC3LE-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3LE-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3LE-EV Pricing and Technical Documents

Пожалуйста, сообщите компании W9 Group свой полный номер заказа, информацию о схеме подключения, условиях установки и необходимых документах, количество и место назначения рынка, чтобы можно было идентифицировать выбранную конфигурацию.

Свяжитесь с W9 Group