JC3LE-EV Type EV 2 Pole RCBO 10KA
TECHNICAL DATA
JC3LE-EV Two-Pole RCBO Product Information
The W9 Group title identifies JC3LE-EV as a Type EV two-pole RCBO with a 10kA designation. For an enquiry, specify the load current, residual-current response and connection arrangement; confirm the actual breaking capacity and release design for the supplied version.
The title states 10kA, while the retained original table states 6kA; the source descriptions also differ on the release design. Confirm these details on one datasheet matching the offered order code.
| Product code | JC3LE-EV | |
| Standard | IEC61009-1, EN61009-1 | |
| Electrical features | Rated current In (A) | 6, 10, 16, 20, 25, 32, 40, 63 |
| Type | Electronic | |
| Type(wave from of the earth leakage sensed) | A are available | |
| Poles | 2Pole | |
| Rated voltage Ue (V) | 230/240 | |
| Rated sensitivity IΔn | 30mA, 100mA, 300mA | |
| Insulation voltage Ui (V) | 500 | |
| Rated frequency | 50/60Hz | |
| Rated breaking capacity | 6KA | |
| Rated impulse withstand voltage (1.2/50) Uimp (V) | 6,000 | |
| Dielectric test voltage at ind.Freq. for 1 min (KV) | 2 | |
| Pollution degree | 2 | |
| Thermo-magnetic release characteristic | B, C | |
| Mechanical features | Electrical life | 2,000 |
| Mechanical life | 10,000 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Reference temperature for setting of thermal element(℃) | 30 | |
| Ambient temperature(with daily average ≤35℃) | -5…+40 | |
| Storage temperature(℃) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25mm2/18-3AWG | |
| Terminal size top/bottom for Busbar | 10mm2/18-8AWG | |
| Tightening torque | 2.5N*m/22In-lbs | |
| Mounting | On DIN rail EN 60715(35mm) | |
| Connection | From top or bottom are available | |
SELECTION GUIDE
Selecting JC3LE-EV 2 pole RCBO for Your Installation
Use JC3LE-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
Select load and overcurrent duty
Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.
Specify residual-current response
Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.
Check the EV protection arrangement
For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.
Confirm pole and terminal wiring
Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.
ABOUT W9 GROUP
W9 Group Support for JC3LE-EV Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3LE-EV enquiry, contact W9 Group about configuration and matching product documents.

RELATED RESOURCES
Request JC3LE-EV Two-Pole RCBO Wiring and Trip-Curve Data
Use technical support and related products to specify JC3LE-EV. Request a datasheet and wiring diagram matching the selected JC3LE-EV configuration.
RELATED PRODUCTJCR2-63 RCBOCompare function and configuration; request separate model ratings
DOCUMENTSW9 Group download centreRequest the current document for your quoted JC3LE-EV variant
BUYER FAQ
JC3LE-EV Two-Pole RCBO Ratings and Wiring FAQs
Find answers about JC3LE-EV selection, configuration and ordering.
Does this RCBO provide both leakage and overcurrent protection?
It is listed as an RCBO. Confirm the offered release, residual-current response, current option and fault rating using one matching datasheet.
Which breaking rating should I specify?
Request the current order-code rating schedule from W9 Group. Confirm the breaking capacity together with operating voltage and test standard before selecting the unit.
Is the release electronic or electromagnetic?
Confirm the release design for the exact quoted unit from its nameplate and technical documentation. Do not use a different version’s operating principle.
Which sensitivity should be selected?
Select the required sensitivity using the circuit design and the matching ordered configuration. Confirm the residual-current type and test-circuit instructions at the same time.
Does the EV name establish smooth DC detection?
A dedicated smooth DC detection function is not established for this exact target. Confirm the charger protection arrangement and any separate device required.
What must be confirmed for the two-pole connection?
Request the line, neutral, supply and load diagram, together with the test-circuit connection and permitted terminal orientation.
What should I send for a JC3LE-EV quotation?
Send the complete JC3LE-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete JC3LE-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request JC3LE-EV Pricing and Technical Documents
Tell W9 Group your complete order code, circuit duty, installation conditions and required documents, quantity and destination market so the selected configuration can be identified.