JCSD-40 Ac Surge Protection Device
W9 Group lists JCSD-40 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 20 kA, maximum discharge current Imax of 40 kA and maximum continuous AC operating voltage Uc of 275 V. Request the selected configuration and matching technical documents from W9 Group.
- Protection against short AC voltage transients
- Plug-in cartridge for servicing
- Local indication with a remote-contact option
JCSD-40 monitoring in an AC panel
The JCSD-40 limits short voltage spikes from switching or lightning. The replaceable protection module has its own status indicator, so maintenance staff can identify the affected module at the board.








TECHNICAL DATA
JCSD-40 Type 2 AC Surge Protection Device Specifications
W9 Group lists JCSD-40 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 20 kA, maximum discharge current Imax of 40 kA and maximum continuous AC operating voltage Uc of 275 V.
| Technology | MOV, MOV+GSG are available |
| Type | Type2 |
| Network | 230 V single-phase 400 V 3-phase |
| Max. AC operating voltage Uc | 275V |
| Temporary Over Voltage (TOV) Charasteristics – 5 sec. UT | 335 Vac withstand |
| Temporary Over Voltage (TOV) Charasteristics – 120 mn UT | 440 Vac disconnection |
| Nominal discharge current In | 20 kA |
| Max. discharge current Imax | 40kA |
| Total Maximum discharge current Imax total | 80kA |
| Withstand on Combination waveform IEC 61643-11 Uoc | 6kV |
| Protection level Up | 1.5kV |
| Protection level N/PE at 5 kA | 0.7 kV |
| Residual voltage L/PE at 5 kA | 0.7 kV |
| Admissible short-circuit current | 25kA |
| Connection to Network | By screw terminals: 2.5-25 mm² |
| Mounting | Symmetrical rail 35 mm (DIN 60715) |
| Operating temperature | -40 / +85°C |
| Protection rating | IP20 |
| Failsafe mode | Disconnection from AC network |
| Disconnection indicator | 1 mechanical indicator by pole – Red/Green |
| Fuses | 50 A mini. – 125 A max. – Fuses Type gG |
| Standards compliance | IEC 61643-11 / EN 61643-11 |
JCSD-40 product details in pictures



SELECTION GUIDE
Selecting a 275V AC SPD with 20kA In and 40kA Imax
Specify the supply voltage, earthing system, pole arrangement, SPD classification and backup protection when you request a JCSD-40 quotation from W9 Group.
Choose the module arrangement to suit the supply. A visual indicator is sufficient for local checks; specify the remote indication version when the alarm must reach a separate monitoring point.
Match the supply network
For JCSD-40, specify single-phase or three-phase supply and the earthing arrangement so the connection scheme can be confirmed.
Check surge ratings
Compare Uc, Up and discharge-current ratings in the matching datasheet; confirm classification and any impulse-current rating required by the project.
Check protective coordination
Ask for the required backup protection, conductor sizing and installation connection drawing for the selected SPD.
Plan inspection and replacement
Request status-indicator instructions, replacement-module compatibility and any remote indication option for the offered version.
ABOUT W9 GROUP
W9 Group Type 2 AC SPD Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCSD-40 enquiry, contact W9 Group about configuration and matching product documents.

JCSD-40 cartridge condition and backup protection
The protection element can disconnect at the end of its service life. Check the red or green indicator on each pole and use the fuse information in the technical schedule when coordinating the SPD with the board.
RELATED RESOURCES
JCSD-40 Type 2 AC SPD Technical Document Requests
Use W9 Group technical support and the product directory to specify JCSD-40. Request the matching datasheet before ordering.
PRODUCT DIRECTORYExplore W9 Group productsBrowse W9 Group models and request the specifications of the selected product
DOCUMENTSW9 Group download centreRequest the current document for your quoted JCSD-40 variant
BUYER FAQ
Type 2 AC SPD FAQs: Earthing and Surge Ratings
Find answers about JCSD-40 selection, configuration and ordering.
Where is JCSD-40 intended to be used?
The supplier table identifies AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device.
What do In and Imax mean on this page?
They are the nominal and maximum discharge-current labels in the supplier table. Use the associated test data when comparing SPDs; confirm the required project classification separately.
How should I specify the version?
State JCSD-40, supply voltage, earthing arrangement, pole count and required SPD classification; request the corresponding datasheet.
What is needed for a JCSD-40 quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.
What is JCSD-40 used for?
The supplier tables identify this model family for AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device; the page does not certify a universal installation.
How should I compare In and Imax when selecting an AC SPD?
Use the supplier table’s nominal and maximum discharge-current labels together with the project classification and test data. Confirm the required SPD class and wiring before ordering.
PRODUCT ENQUIRY
Request a JCSD-40 Type 2 AC SPD Quotation
Tell W9 Group your supply voltage, earthing system, pole arrangement, SPD classification and backup protection, quantity and destination market so the selected configuration can be identified.