محصولات حفاظت مدار

  • JC3LE-EV نوع EV 2 پولی RCBO 10KA
  • JC3LE-EV Type EV 2 Pole RCBO 10KA Gallery image 2
  • JC3LE-EV Type EV 2 Pole RCBO 10KA Gallery image 3
  • JC3LE-EV نوع EV 2 پولی RCBO 10KA
  • JC3LE-EV Type EV 2 Pole RCBO 10KA Gallery image 2
  • JC3LE-EV Type EV 2 Pole RCBO 10KA Gallery image 3

JC3LE-EV نوع EV 2 قطبی RCBO 10KA

The W9 Group title identifies JC3LE-EV as a Type EV two-pole RCBO with a 10kA designation. For an enquiry, specify the load current, residual-current response and connection arrangement; confirm the actual breaking capacity and release design for the supplied version.

اطلاعات فنی

JC3LE-EV Two-Pole RCBO Product Information

The W9 Group title identifies JC3LE-EV as a Type EV two-pole RCBO with a 10kA designation. For an enquiry, specify the load current, residual-current response and connection arrangement; confirm the actual breaking capacity and release design for the supplied version.

The title states 10kA, while the retained original table states 6kA; the source descriptions also differ on the release design. Confirm these details on one datasheet matching the offered order code.

کد محصول JC3LE-EV
استاندارد IEC61009-1، EN61009-1
ویژگی‌های الکتریکی مقاومت جریان ورودی (A) 6, 10, 16, 20, 25, 32, 40, 63
نوع الکترونیک
نوع (باعث موج در زمین شده و باعث کشف نشت برق شده است) A در دسترس است
پوشندگان لهستانی 2پول
ولتاژ رتبه‌دهی شده Ue (V) 230/240
حساسیت رتبه‌دهی شده IΔn 30mA، 100mA، 300mA
ولتاژ عایق بندی Ui (V) 500
فراوانی رتبهبندی شده ۵۰/۶۰ هرتز
قدرت شکسته شدن بر اساس رتبه بندی 6KA
تولید برق ناپایدار (1.2/50) Uimp (V) 6,000
تنظیم ولتاژ تست دی الکتریک در فرکانس داخلی برای ۱ دقیقه (کیلوولت) 2
سطح آلودگی 2
خاصیت آزاد شدن ترمو-مغناطیسی B، C
ویژگی‌های مکانیکی زندگی الکتریکی 2,000
زمان کارکرد مکانیکی 10,000
نمایشگر موقعیت تماس بله
سطح حفاظت IP20
دمای مرجع برای تنظیم عنصر حرارتی (درجه سانتیگراد) 30
استاندارد دمای محیط (با میانگین روزانه ≤35 ℃) -5…+40
دمای ذخیره سازی (درجه سانتیگراد) -25…+70
ارائه نصب نوع اتصال ترمینال کابل/پیوستهای U-type/پیوستهای Pin-type
ابعاد بالایی/پایینی ترمینال برای کابل 25 میلی متر مربع / 18-3AWG
ابعاد پایانه بالایی/پایینی برای Busbar 10 میلی متر مربع / 18-8AWG
تنگ کردن گشتاور 2.5N*m/22In-lbs
قرارگیری بر روی ریل DIN EN 60715 (35 میلی متر)
اتصال از بالا یا پایین قابل استفاده هستند

راهنمای انتخاب

Selecting JC3LE-EV 2 pole RCBO for Your Installation

Use JC3LE-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Select load and overcurrent duty

Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.

02

Specify residual-current response

Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.

03

Check the EV protection arrangement

For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.

04

Confirm pole and terminal wiring

Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.

Before specifying JC3LE-EV: Confirm the release design, breaking capacity, waveform response and operating voltage for the complete order code.

درباره W9 Group

W9 Group Support for JC3LE-EV Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3LE-EV enquiry, contact W9 Group about configuration and matching product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

Request JC3LE-EV Two-Pole RCBO Wiring and Trip-Curve Data

Use technical support and related products to specify JC3LE-EV. Request a datasheet and wiring diagram matching the selected JC3LE-EV configuration.

سوالات متداول خریداران

JC3LE-EV Two-Pole RCBO Ratings and Wiring FAQs

Find answers about JC3LE-EV selection, configuration and ordering.

Does this RCBO provide both leakage and overcurrent protection?

It is listed as an RCBO. Confirm the offered release, residual-current response, current option and fault rating using one matching datasheet.

Which breaking rating should I specify?

Request the current order-code rating schedule from W9 Group. Confirm the breaking capacity together with operating voltage and test standard before selecting the unit.

Is the release electronic or electromagnetic?

Confirm the release design for the exact quoted unit from its nameplate and technical documentation. Do not use a different version’s operating principle.

Which sensitivity should be selected?

Select the required sensitivity using the circuit design and the matching ordered configuration. Confirm the residual-current type and test-circuit instructions at the same time.

Does the EV name establish smooth DC detection?

A dedicated smooth DC detection function is not established for this exact target. Confirm the charger protection arrangement and any separate device required.

What must be confirmed for the two-pole connection?

Request the line, neutral, supply and load diagram, together with the test-circuit connection and permitted terminal orientation.

What should I send for a JC3LE-EV quotation?

Send the complete JC3LE-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3LE-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3LE-EV Pricing and Technical Documents

به گروه W9 کد کامل سفارش، وظایف مدار، شرایط نصب و مدارک مورد نیاز، تعداد و بازار مقصد را اطلاع دهید تا بتوان پیکربندی انتخاب شده را شناسایی کرد.

تماس با گروه W9