JC3LE-50H 1P+N مینی RCBO واحدی با ظرفیت 10 کیلو آمپری
اطلاعات فنی
JC3LE-50H 10kA 1P+N Single Module RCBO Specifications
W9 Group lists JC3LE-50H as a single-module 1P+N electronic RCBO with a stated 10 kA breaking capacity, combining earth-leakage, overload and short-circuit protection.
| مدل | JC3LE-50H | |
|---|---|---|
| Pole arrangement | 1P+N | |
| Module format | Single module | |
| Construction | الکترونیک | |
| Rated current range | 6–40 A; confirm the exact individual ratings | |
| Breaking capacity | 10 kA | |
| Residual-current sensitivity | 30 mA, 100 mA | |
| Waveform options | Type A or Type AC | |
| Switching | Double-pole switching | |
| Standards listed by W9 Group | IEC 61009-1, EN61009-1; request model-specific documents | |
راهنمای انتخاب
Selecting a 10kA RCBO with 30mA or 100mA Sensitivity
Specify the rated current, waveform type, residual-current sensitivity, operating voltage, trip curve and required technical documents when requesting a JC3LE-50H quotation from W9 Group.
Check the 10 kA rating
Check the stated 10 kA breaking capacity against the circuit’s prospective fault current using the selected device’s rating documents.
Specify current explicitly
JC3LE-50H lists a 6–40 A range. Specify the current required by the circuit.
Choose detection settings
Type A or Type AC and 30 mA or 100 mA sensitivities are listed. Confirm the chosen combination on the quotation.
Verify board compatibility
Request operating voltage, trip curve, dimensions and connection instructions for the planned distribution board.
درباره W9 Group
W9 Group 10kA 1P+N RCBO Supply and Support
Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JC3LE-50H order, contact W9 Group about the required configuration and product documents.

منابع مرتبط
JC3LE-50H 10kA 1P+N RCBO Technical Document Requests
Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JC3LE-50H configuration.
سوالات متداول خریداران
10kA RCBO FAQs: Current, Module Width and Trip Curves
Find answers about ratings, configuration and ordering.
Is JC3LE-50H listed as a 10 kA RCBO?
W9 Group lists JC3LE-50H as a 10 kA RCBO. Confirm suitability for the prospective fault current using the rating documents for the selected configuration. Breaking capacity and rated load current are separate specifications.
Can I request JC3LE-50H as a 40 A RCBO?
W9 Group lists a 6–40 A current range for JC3LE-50H. For a 40 A RCBO enquiry, specify the residual-current sensitivity and Type A or Type AC detection. Confirm availability of that exact configuration on the quotation.
Which residual-current sensitivities are listed?
JC3LE-50H lists 30 mA and 100 mA sensitivities. Select the required value and confirm the detection type for the quoted configuration.
What is needed for a JC3LE-50H quotation?
Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.
سؤال و جواب درباره محصول
Request a JC3LE-50H 10kA 1P+N RCBO Quotation
Tell W9 Group your rated current, waveform type, residual-current sensitivity, operating voltage, trip curve and required technical documents, quantity and destination market so the selected configuration can be identified.