JCB2LE-EV 2 پین RCBO
اطلاعات فنی
JCB2LE-EV 2 pole RCBO specifications
The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval.
| مدل | JCB2LE-EV |
|---|---|
| حفاظت | Residual current, overload and short circuit |
| Current options | 32A / 40A |
| Residual-current response | Type A |
| Sensitivity | 30mA |
| توانایی شکست دهی ذکر شده | 10kA |
| Trip curves | B / C |
| پوشندگان لهستانی | 2 pole; neutral switched |
راهنمای انتخاب
JCB2LE-EV EV charging RCBO selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCB2LE-EV quotation from W9 Group.
Select load and overcurrent duty
Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.
Specify residual-current response
Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.
Check the EV protection arrangement
For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.
Confirm pole and terminal wiring
Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.
درباره W9 Group
W9 Group support for JCB2LE-EV RCBO
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB2LE-EV enquiry, contact W9 Group about configuration and matching product documents.

منابع مرتبط
JCB2LE-EV Type A residual current protection documents
Use technical support and related products to specify JCB2LE-EV. Request a datasheet and wiring diagram matching the selected JCB2LE-EV configuration.
سوالات متداول خریداران
JCB2LE-EV two pole RCBO FAQs
Find answers about JCB2LE-EV selection, configuration and ordering.
Which protection functions are combined?
The summary identifies residual-current, overload and short-circuit protection in an electronic two-pole device. Confirm the complete ordered version.
Which current and curve options are listed?
W9 Group lists 32A and 40A, with B or C overcurrent characteristics. Select the curve using load starting behavior and the required conductor protection.
Does Type A mean smooth DC detection is included?
No smooth DC detection threshold is established by this target summary. Confirm the charger’s DC detection and the required upstream arrangement separately.
What residual-current sensitivity is listed?
The summary lists 30mA. Confirm the required sensitivity and exact protection arrangement against the charger instructions and installation rules.
Does this RCBO include open-PEN protection?
An independent open-PEN function is not established for the target product. Confirm any required separate protection instead of inferring it from the EV name.
Can the supply enter from either end?
The summary describes top and bottom wiring. Confirm the permitted supply terminals, neutral path and test-circuit operation from the matching installation drawing.
What is needed for a JCB2LE-EV quotation?
اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونهها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.
سؤال و جواب درباره محصول
Request a JCB2LE-EV 2 pole RCBO quotation
به گروه W9 کد کامل سفارش، وظایف مدار، شرایط نصب و مدارک مورد نیاز، تعداد و بازار مقصد را اطلاع دهید تا بتوان پیکربندی انتخاب شده را شناسایی کرد.