JCB2LE-EV 2極RCBO
技術データ
JCB2LE-EV 2 pole RCBO specifications
The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval.
| モデル | JCB2LE-EV |
|---|---|
| 保護 | Residual current, overload and short circuit |
| Current options | 32A / 40A |
| Residual-current response | Type A |
| Sensitivity | 30mA |
| リストされたブレーク容量 | 10kA |
| Trip curves | B / C |
| ポーランド人 | 2 pole; neutral switched |
選定ガイド
JCB2LE-EV EV charging RCBO selection
Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCB2LE-EV quotation from W9 Group.
負荷および過電流の選択
負荷電流、導体の仕様および想定故障電流を記載してください。発注済みの定格電流と時限特性曲線を確認してください。.
残留電流応答を指定する
必要な波形応答および感度については、正確な製品仕様書と接続機器の要件に基づいて確認してください。.
EV保護体制を確認してください
EV充電回路については、充電器の取扱説明書および直流検出回路を提供してください。設置にあたり別途必要な保護措置があるか確認してください。.
ポールおよび端子の配線を確認してください。
供給回路、負荷回路、中性線回路および試験回路の配線図を要求してください。端子台の容量、取付方法、および配電盤との互換性を確認してください。.
W9 GROUPについて
W9 Group support for JCB2LE-EV RCBO
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB2LE-EV enquiry, contact W9 Group about configuration and matching product documents.

関連リソース
JCB2LE-EV Type A residual current protection documents
Use technical support and related products to specify JCB2LE-EV. Request a datasheet and wiring diagram matching the selected JCB2LE-EV configuration.
購入者のよくある質問
JCB2LE-EV two pole RCBO FAQs
Find answers about JCB2LE-EV selection, configuration and ordering.
Which protection functions are combined?
The summary identifies residual-current, overload and short-circuit protection in an electronic two-pole device. Confirm the complete ordered version.
Which current and curve options are listed?
W9 Group lists 32A and 40A, with B or C overcurrent characteristics. Select the curve using load starting behavior and the required conductor protection.
Does Type A mean smooth DC detection is included?
No smooth DC detection threshold is established by this target summary. Confirm the charger’s DC detection and the required upstream arrangement separately.
What residual-current sensitivity is listed?
The summary lists 30mA. Confirm the required sensitivity and exact protection arrangement against the charger instructions and installation rules.
Does this RCBO include open-PEN protection?
An independent open-PEN function is not established for the target product. Confirm any required separate protection instead of inferring it from the EV name.
Can the supply enter from either end?
The summary describes top and bottom wiring. Confirm the permitted supply terminals, neutral path and test-circuit operation from the matching installation drawing.
What is needed for a JCB2LE-EV quotation?
必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.
製品のお問い合わせ
Request a JCB2LE-EV 2 pole RCBO quotation
W9 Group にご注文の全コード、回路の仕様、設置条件、必要な書類、数量、および配送先市場を伝えてください。そうすれば、選択された構成が特定できます。.