JCSD-40 Ac Surge Protection Device

W9 Group lists JCSD-40 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 20 kA, maximum discharge current Imax of 40 kA and maximum continuous AC operating voltage Uc of 275 V. Request the selected configuration and matching technical documents from W9 Group.

技術データ

JCSD-40 Type 2 AC Surge Protection Device Specifications

W9 Group lists JCSD-40 as an AC surge protection device for transient overvoltages on electrical supply circuits. The technical table specifies nominal discharge current In of 20 kA, maximum discharge current Imax of 40 kA and maximum continuous AC operating voltage Uc of 275 V.

Technology MOV, MOV+GSG are available
タイプ Type2
Network 230 V single-phase
400 V 3-phase
Max. AC operating voltage   Uc 275V
Temporary Over Voltage (TOV) Charasteristics – 5 sec.   UT 335 Vac withstand
Temporary Over Voltage (TOV) Charasteristics – 120 mn   UT 440 Vac disconnection
Nominal discharge current    In 20 kA
Max. discharge current  Imax 40kA
Total Maximum discharge current   Imax total 80kA
Withstand on Combination waveform IEC 61643-11  Uoc 6kV
Protection level  Up 1.5kV
Protection level N/PE at 5 kA 0.7 kV
Residual voltage L/PE at 5 kA 0.7 kV
Admissible short-circuit current 25kA
Connection to Network By screw terminals: 2.5-25 mm²
取り付け Symmetrical rail 35 mm (DIN 60715)
Operating temperature -40 / +85°C
Protection rating IP20
Failsafe mode  Disconnection from AC network
Disconnection indicator 1 mechanical indicator by pole – Red/Green
Fuses 50 A mini. – 125 A max. – Fuses Type gG
Standards compliance IEC 61643-11 / EN 61643-11

選定ガイド

Selecting a 275V AC SPD with 20kA In and 40kA Imax

Specify the supply voltage, earthing system, pole arrangement, SPD classification and backup protection when you request a JCSD-40 quotation from W9 Group.

01

Match the supply network

For JCSD-40, specify single-phase or three-phase supply and the earthing arrangement so the connection scheme can be confirmed.

02

Check surge ratings

Compare Uc, Up and discharge-current ratings in the matching datasheet; confirm classification and any impulse-current rating required by the project.

03

Check protective coordination

Ask for the required backup protection, conductor sizing and installation connection drawing for the selected SPD.

04

Plan inspection and replacement

Request status-indicator instructions, replacement-module compatibility and any remote indication option for the offered version.

Before ordering JCSD-40: confirm supply voltage, earthing system, pole arrangement, SPD classification and backup protection, the matching datasheet and the installation drawing.

W9 GROUPについて

W9 Group Type 2 AC SPD Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCSD-40 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JCSD-40 Type 2 AC SPD Technical Document Requests

Use W9 Group technical support and the product directory to specify JCSD-40. Request the matching datasheet before ordering.

購入者のよくある質問

Type 2 AC SPD FAQs: Earthing and Surge Ratings

Find answers about JCSD-40 selection, configuration and ordering.

Where is JCSD-40 intended to be used?

The supplier table identifies AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device.

What do In and Imax mean on this page?

They are the nominal and maximum discharge-current labels in the supplier table. Use the associated test data when comparing SPDs; confirm the required project classification separately.

How should I specify the version?

State JCSD-40, supply voltage, earthing arrangement, pole count and required SPD classification; request the corresponding datasheet.

What is needed for a JCSD-40 quotation?

必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.

What is JCSD-40 used for?

The supplier tables identify this model family for AC supply circuits. Confirm the supply voltage, earthing arrangement and connection layout for the selected device; the page does not certify a universal installation.

How should I compare In and Imax when selecting an AC SPD?

Use the supplier table’s nominal and maximum discharge-current labels together with the project classification and test data. Confirm the required SPD class and wiring before ordering.

製品のお問い合わせ

Request a JCSD-40 Type 2 AC SPD Quotation

Tell W9 Group your supply voltage, earthing system, pole arrangement, SPD classification and backup protection, quantity and destination market so the selected configuration can be identified.