技術データ
CJ19 コンデンサ切換用接触器の仕様
CJ19コンデンサ切換用接触器は、無効電力補償装置における低圧シャントコンデンサの切換用としてW9グループに登録されています。同資料には、突入電流制限回路について記載があります。選定するサイズについては、コンデンサのステップ容量、系統電圧、切替負荷およびコイル電源を指定してください。.
| アイテム | シージェイ19-25 | シージェー19-32 | CJ19-43 | CJ19-63 | CJ19-95 | CJ19-115 | CJ19-150 | CJ19-170 |
| Controllable capacitor 220V | 6 | 9 | 10 | 15 | 28.8(240V) | 34.(240V) | 46(240V) | 52(240V) |
| Capacity 380V | 12 | 18 | 20 | 30 | 50(400V) | 60(400V) | 80(400V | 90(400V) |
| Rated 1solation Voltage Ui V |
500 | 690 | ||||||
| Rated Operational Voltage Ue V |
220/240+ 380/400 | |||||||
| Conventional thermal current 1th A | 25 | 32 | 43 | 63 | 95 | 200 | 200 | 275 |
| Rated Operational current 1eA (380V) | 17 | 23 | 29 | 43 | 72.2 (400V) | 87 (400V) | 115(400V) | 130(400V) |
| Restrained surge capacity | 20 1e | |||||||
| Controlled power voltage | 110 127 220 380 | |||||||
| 補助連絡先 | AC.15: 360VA DC.13: 33W 1th:10A | |||||||
| Operating Frequency cycles/h | 120 | |||||||
| Electrical durability 104 | 10 | |||||||
| Mechanical durability 104 | 100 | |||||||
| モデル | Amax | Bmax | Cmax | Dmax | E | F | Note | |
| シージェイ19-25 | 80 | 47 | 124 | 76 | 34/35 | 50/60 | Not only fixed by screws but also could be fixed with 35mm din rail |
|
| シージェー19-32 | 90 | 58 | 132 | 86 | 40 | 48 | ||
| CJ19-43 | 90 | 58 | 136 | 86 | 40 | 48 | ||
| CJ19-63 | 132 | 79 | 150 | . | . | . | Not only fixed by screws but also could | |
| CJ19-95 | 135 | 87 | 158 | . | . | . | be fixed with 35mm and 75mm din rail | |
| CJ19-115 | 200 | 120 | 192 | 155 | 115(400V) | |||
| CJ19-150 | 200 | 120 | 192 | 155 | Not only fixed by screws but also could | |||
| CJ19-170 | 200 | 120 | 192 | 155 | be fixed with two 35mm din rail | |||
| 6. wiring and installation | ||||||||
| 6.1 The connection terminals are protected through insulation cover+ which is reliable and secure for installation and operation: | ||||||||
| 6.2 For CJ19.25λ43+ screws are available for installation+ as well as the D1N rail: | ||||||||
| for CJ19.63λ95+ 35mm or 75mm standard rail are available for installation. | ||||||||
| for CJ19.115λ170+ screws are available for installation+ as well as two 35mm D1N rail. | ||||||||
選定ガイド
Selecting a Capacitor Bank Contactor by Load and Coil Voltage
Specify the capacitor step capacity, system voltage/frequency, coil supply, switching sequence and mounting size when requesting a CJ19 quotation from W9 Group.
State the capacitor step
Provide the step capacity, system voltage and frequency. Request the matching model-specific capacitor-switching rating.
Check switching inrush
Confirm that the offered inrush-limiting arrangement is suitable for the bank configuration and switching sequence.
Choose the coil and controls
Specify the control-supply voltage and frequency together with the required auxiliary contacts.
Confirm size and mounting
Request the selected model’s dimensions and screw / rail fixing details. Confirm terminal capacity and protection coordination.
W9 GROUPについて
W9 Group Capacitor Contactor Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a CJ19 enquiry, contact W9 Group about configuration and matching product documents.

関連リソース
CJ19 Capacitor Switching Contactor Rating and Coil Information
Use W9 Group technical support and the product directory to specify CJ19. Request a datasheet and wiring diagram matching the selected CJ19 configuration.
購入者のよくある質問
CJ19 Contactor FAQs: Inrush Current, Capacity and Mounting
Find answers about CJ19 selection, configuration and ordering.
What is CJ19 designed to switch?
The supplier lists low-voltage shunt capacitors used in reactive-power compensation equipment. It is a capacitor-switching contactor rather than a general protection device.
Why does capacitor switching need an inrush arrangement?
The source describes restraint of switching inrush for capacitor duty. Confirm the offered arrangement against the bank size and operating conditions.
Can I size CJ19 using only its thermal current?
No. Confirm the capacitor-switching capacity at the actual system voltage. A thermal-current row alone does not establish the permitted capacitor step.
What capacitor capacity can each model switch?
The source has a model and voltage matrix, but its units and series coverage are not sufficiently clear for a universal capacity claim. Confirm the manufacturer’s capacity table for the offered model.
Which coil voltage should be ordered?
Specify the actual control voltage and frequency, then confirm the coil code. The capacitor-bank supply and contactor-coil supply are separate selection inputs.
Does every CJ19 size use the same DIN rail?
No common fixing should be assumed. The page describes different screw and rail arrangements by size; confirm the mounting drawing for the chosen frame.
What is needed for a CJ19 quotation?
必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.
製品のお問い合わせ
Request a CJ19 Capacitor Switching Contactor Quotation
Tell W9 Group your capacitor step capacity, system voltage/frequency, coil supply, switching sequence and mounting size, quantity and destination market so the selected configuration can be identified.