JC3LE-4P 4極電磁式RCBO

W9 Group offers JC3LE-4P as a 4-pole electromagnetic RCBO for consumer units and distribution boards. It combines residual-current, overload and short-circuit protection and uses separate handles for the overcurrent and residual-current functions.

技術データ

JC3LE-4P 4 Pole Electromagnetic RCBO Specifications

W9 Group offers JC3LE-4P as a 4-pole electromagnetic RCBO for consumer units and distribution boards. It combines residual-current, overload and short-circuit protection and uses separate handles for the overcurrent and residual-current functions.

スタンダード IEC61009-1、EN61009-1
電気機能 定格電流(A) 6, 10, 16, 20, 25, 32, 40
タイプ 電磁
タイプ(地球の漏れを検知した波の形式) Aは入手可能です
ポーランド人 4極
定格電圧 Ue(V) 400/415
評価感度 IΔn 30mA、100mA、300mA
絶縁電圧 Ui(V) 500
定格周波数 50/60Hz
定格断面積 6KA
定格インパルス耐圧(1.2/50)Uimp(V) 6,000
インダクタンス試験電圧(1分間、KV) 2
汚染度 2
熱磁性放出特性 B、C
機械的特徴 電気寿命 2,000
機械的寿命 10,000
接触位置インジケーター はい
保護レベル IP20
サーマルエレメントの設定時の基準温度(℃) 30
周囲温度(1日の平均が35℃以下) -5…+40
保管温度(℃) -25…+70
インストール ターミナル接続タイプ ケーブル/U型バスバー/ピン型バスバー
ケーブル用の端末サイズの上部/下部 25mm2/18-3AWG
バスバー用端子サイズの上部/下部 10mm2/18-8AWG
締めトルク 2.5N*m/22インチ-lbs
取り付け DINレール用 EN 60715(35mm)
接続 上部または下部から利用可能です

選定ガイド

Selecting a 4 Pole RCBO by Leakage Sensitivity and Trip Curve

Specify the required current, prospective fault current, waveform type, residual-current sensitivity, four-pole wiring and operating documents when requesting a JC3LE-4P quotation from W9 Group.

01

Confirm breaking capacity

Provide the circuit's prospective fault current and request the marked breaking rating and matching technical documents.

02

Choose current and detection

State the required current, residual-current sensitivity and waveform. Confirm the exact combination on the quotation.

03

Review separate handles

JC3LE-4P is described with separate overcurrent and residual-current handles. Request operation and test instructions.

04

Check four-pole connections

Request neutral-terminal identification and the approved wiring diagram for the intended circuit.

Before specifying JC3LE-4P: Confirm the selected current rating, marked breaking capacity and residual-current waveform type before specifying JC3LE-4P. Request the approved wiring diagram, neutral-terminal identification and handle-operation instructions.

W9 GROUPについて

W9 Group 4 Pole Electromagnetic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JC3LE-4P order, contact W9 Group about the required configuration and product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JC3LE-4P 4 Pole Electromagnetic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JC3LE-4P configuration.

購入者のよくある質問

RCBO FAQs: 4 Pole Ratings and Configuration Checks

Find answers about configuration, installation documents and ordering.

What construction and pole arrangement are listed?

JC3LE-4P is listed as a 4-pole electromagnetic RCBO. Confirm the terminal diagram and installation requirements for the selected device.

How do I specify current and breaking capacity?

Provide the circuit current and prospective fault-current requirements. Ask W9 Group to confirm the device's marked current and breaking ratings in the quotation and technical documents.

How are the protection functions operated?

W9 Group describes separate handles for the overcurrent and residual-current functions. Request the operating and testing instructions before installation.

What is needed for a JC3LE-4P quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

How do I specify JC3LE-4P residual-current sensitivity?

State the required residual-current sensitivity, load-current rating and waveform response separately. Ask W9 Group to confirm the available JC3LE-4P combination on the matching order-code datasheet.

What board-fit information is needed for JC3LE-4P?

Request the JC3LE-4P outline, mounting and terminal drawings. Confirm space for the selected four-pole device, conductors and operating handles before finalizing the distribution-board layout.

Can I assume that an accessory for another RCBO fits JC3LE-4P?

Confirm accessory compatibility by the complete JC3LE-4P order code and the supplier fitting instructions. Request the matching accessory list rather than assuming that a shared product family establishes fit.

製品のお問い合わせ

Request a JC3LE-4P 4 Pole Electromagnetic RCBO Quotation

Tell W9 Group your required current, prospective fault current, waveform type, residual-current sensitivity, four-pole wiring and operating documents, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ