회로 보호 제품

  • RCBO 잔류 전류 차단기: 과전류 및 누설 보호 기능, 차동 차단기 JCB2LE-EV 2폴
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3
  • RCBO 잔류 전류 차단기: 과전류 및 누설 보호 기능, 차동 차단기 JCB2LE-EV 2폴
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-EV 2 Pole Gallery image 3

JCB2LE-EV 2극 RCBO

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JCB2LE-EV 2 pole RCBO specifications

The JCB2LE-EV 2 pole RCBO combines residual-current, overload and short-circuit protection. W9 Group lists an electronic design with Type A residual-current response. For EV charging, match the charger’s DC protection arrangement rather than treating the EV suffix as a complete installation approval.

JCB2LE-EV product specifications
모델 JCB2LE-EV
보호 Residual current, overload and short circuit
Current options 32A / 40A
Residual-current response Type A
Sensitivity 30mA
기재된 파괴 용량 10kA
Trip curves B / C
폴란드인 2 pole; neutral switched

선정 가이드

JCB2LE-EV EV charging RCBO selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JCB2LE-EV quotation from W9 Group.

01

Select load and overcurrent duty

Provide load current, conductor details and prospective fault current. Confirm the ordered current and time-current curve.

02

Specify residual-current response

Confirm the required waveform response and sensitivity using the exact product schedule and the connected equipment requirements.

03

Check the EV protection arrangement

For an EV charging circuit, provide the charger instructions and its DC detection arrangement. Confirm any separate protection required by the installation.

04

Confirm pole and terminal wiring

Request the supply, load, neutral and test-circuit diagram. Confirm terminal capacity, mounting and distribution-board compatibility.

Before specifying JCB2LE-EV: Confirm operating voltage, charger DC protection, pole wiring and installation requirements for the exact offered RCBO.

W9 그룹 소개

W9 Group support for JCB2LE-EV RCBO

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB2LE-EV enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCB2LE-EV Type A residual current protection documents

Use technical support and related products to specify JCB2LE-EV. Request a datasheet and wiring diagram matching the selected JCB2LE-EV configuration.

구매자 FAQ

JCB2LE-EV two pole RCBO FAQs

Find answers about JCB2LE-EV selection, configuration and ordering.

Which protection functions are combined?

The summary identifies residual-current, overload and short-circuit protection in an electronic two-pole device. Confirm the complete ordered version.

Which current and curve options are listed?

W9 Group lists 32A and 40A, with B or C overcurrent characteristics. Select the curve using load starting behavior and the required conductor protection.

Does Type A mean smooth DC detection is included?

No smooth DC detection threshold is established by this target summary. Confirm the charger’s DC detection and the required upstream arrangement separately.

What residual-current sensitivity is listed?

The summary lists 30mA. Confirm the required sensitivity and exact protection arrangement against the charger instructions and installation rules.

Does this RCBO include open-PEN protection?

An independent open-PEN function is not established for the target product. Confirm any required separate protection instead of inferring it from the EV name.

Can the supply enter from either end?

The summary describes top and bottom wiring. Confirm the permitted supply terminals, neutral path and test-circuit operation from the matching installation drawing.

What is needed for a JCB2LE-EV quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JCB2LE-EV 2 pole RCBO quotation

W9 Group에 주문번호, 회로 사용 목적, 설치 조건 및 필요한 서류, 수량 및 판매처를 알려주시면 선택된 구성이 확인될 수 있습니다.

W9 그룹에 문의하기