회로 보호 제품

  • EV 충전기용 RCBO 10kA 차동 차단기 JCR2-63 2극 1P+N
  • RCBO for EV Charger 10kA Differential circuit breaker JCR2-63 2 Pole 1P+N Gallery image 2
  • EV 충전기용 RCBO 10kA 차동 차단기 JCR2-63 2극 1P+N
  • RCBO for EV Charger 10kA Differential circuit breaker JCR2-63 2 Pole 1P+N Gallery image 2

JCR2-63 RCBO

The JCR2-63 RCBO combines residual-current, overload and short-circuit protection. W9 Group lists a 2-pole configuration, 6–63 A currents, B or C curves and a 10 kA breaking rating. For EV charging circuits, specify the charger’s DC residual-current protection arrangement before selecting the RCBO type. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JCR2-63 2 Pole 10kA RCBO Specifications

The JCR2-63 RCBO combines residual-current, overload and short-circuit protection. W9 Group lists a 2-pole configuration, 6–63 A currents, B or C curves and a 10 kA breaking rating. For EV charging circuits, specify the charger’s DC residual-current protection arrangement before selecting the RCBO type.

표준 IEC61009-1 ,  EN61009-1
Electrical
features
정격 전류(A) 6, 10, 16, 20, 25, 32, 40,50,63
형태 전자기력
형태(지하 배수관에서 감지된 파형) A or AC are available
폴란드인 2 Pole
정격 전압 Ue(V) 230/240
Rated sensitivity I△n 30mA,100mA,300mA are available
절연 전압 Ui(V) 500
정격 주파수 50/60Hz
최대 절단 용량 10kA
정격 임펄스 내전압(1.2/50) Uimp (V) 6000
Break time under I△n (s) ≤0.1
오염 정도 2
열 자성 방출 특성 B, C
Mechanical
features
전기 수명 2, 000
기계적 수명 2, 000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2  / 18-3 AWG
버스바용 터미널 사이즈 상단/하단 10mm2  / 18-8 AWG
강력한 토크 2.5 N*m  /  22 In-Ibs.
장착 DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착
연결 From top or bottom

선정 가이드

How to Select a Type A or Type AC 30mA RCBO

Specify the current, curve, residual-current type, sensitivity, charger details and pole arrangement when requesting a JCR2-63 quotation from W9 Group.

01

Choose the circuit current

Choose the rated current from the listed 6–63 A options and match the curve to load starting behavior.

02

Select residual-current response

Specify Type A or Type AC and the required sensitivity. Confirm the waveform requirements of the connected equipment.

03

Check EV charger requirements

Confirm whether the charger provides DC residual-current detection and which upstream RCD arrangement its manufacturer requires.

04

Confirm board integration

Request the pole connection diagram, terminal details and distribution-board compatibility for the selected version.

Before specifying JCR2-63: Confirm residual-current type, sensitivity, neutral switching and the EV charger’s DC detection requirements. Voltage dependence and endurance claims are inconsistent in the source and are excluded.

W9 그룹 소개

W9 Group RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCR2-63 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JCR2-63 RCBO Datasheet and Wiring Information

Use W9 Group technical support and the product directory to specify JCR2-63. Request a datasheet and wiring diagram matching the selected JCR2-63 configuration.

구매자 FAQ

JCR2-63 RCBO FAQs for EV Charger Circuit Selection

Find answers about JCR2-63 selection, configuration and ordering.

What protection does JCR2-63 combine?

It combines residual-current protection with overload and short-circuit protection, unlike an RCCB that requires separate overcurrent protection.

Which currents and trip curves can I specify?

The published schedule lists 6, 10, 16, 20, 25, 32, 40, 50 and 63 A, with B or C trip curves. Confirm the complete order code.

Is a 30mA RCBO the only sensitivity option?

No. The catalog also lists 100 mA and 300 mA. Select sensitivity according to the circuit protection requirements and applicable installation rules.

Does a Type A RCBO detect smooth DC residual current?

Do not treat Type A as Type B protection. Confirm the required residual-current waveform coverage and any separate DC detection for the connected equipment.

Can JCR2-63 be specified for an EV charger?

The page markets it for EV charging, but suitability depends on the charger, DC residual-current detection and local installation requirements. Confirm the complete protection arrangement before ordering.

Does this RCBO provide open-PEN protection?

An independent open-PEN protection function is not established by the target-model data. Confirm any required separate device rather than assuming it is included.

What is needed for a JCR2-63 quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JCR2-63 RCBO Quotation

Tell W9 Group your current, curve, residual-current type, sensitivity, charger details and pole arrangement, quantity and destination market so the selected configuration can be identified.

W9 그룹에 문의하기