Productos de protección de circuitos

  • RCBO para cargador de EV Disjuntor diferencial de 10kA JCR2-63 2 polos 1P+N Imagen de la galería 1
  • RCBO for EV Charger 10kA Differential circuit breaker JCR2-63 2 Pole 1P+N Gallery image 2
  • RCBO para cargador de EV Disjuntor diferencial de 10kA JCR2-63 2 polos 1P+N Imagen de la galería 1
  • RCBO for EV Charger 10kA Differential circuit breaker JCR2-63 2 Pole 1P+N Gallery image 2

JCR2-63 RCBO

The JCR2-63 RCBO combines residual-current, overload and short-circuit protection. W9 Group lists a 2-pole configuration, 6–63 A currents, B or C curves and a 10 kA breaking rating. For EV charging circuits, specify the charger’s DC residual-current protection arrangement before selecting the RCBO type. Request the selected configuration and matching technical documents from W9 Group.

DATOS TÉCNICOS

JCR2-63 2 Pole 10kA RCBO Specifications

The JCR2-63 RCBO combines residual-current, overload and short-circuit protection. W9 Group lists a 2-pole configuration, 6–63 A currents, B or C curves and a 10 kA breaking rating. For EV charging circuits, specify the charger’s DC residual-current protection arrangement before selecting the RCBO type.

JCR2-63 product specifications
Modelo JCR2-63
Protection Residual current, overload and short circuit
Rated currents 6, 10, 16, 20, 25, 32, 40, 50, 63 A
Polacos 2P; confirm the switched-neutral arrangement
Rated voltage 230 / 240 V
Breaking capacity listed 10 kA
Trip curves B / C
Residual-current types Type A / Type AC
Sensitivity options 30 / 100 / 300 mA
Instalación 35 mm DIN rail
Standards listed IEC 61009-1 / EN 61009-1; request applicable documentation

Guía de selección

How to Select a Type A or Type AC 30mA RCBO

Specify the current, curve, residual-current type, sensitivity, charger details and pole arrangement when requesting a JCR2-63 quotation from W9 Group.

01

Choose the circuit current

Choose the rated current from the listed 6–63 A options and match the curve to load starting behavior.

02

Select residual-current response

Specify Type A or Type AC and the required sensitivity. Confirm the waveform requirements of the connected equipment.

03

Check EV charger requirements

Confirm whether the charger provides DC residual-current detection and which upstream RCD arrangement its manufacturer requires.

04

Confirm board integration

Request the pole connection diagram, terminal details and distribution-board compatibility for the selected version.

Before specifying JCR2-63: Confirm residual-current type, sensitivity, neutral switching and the EV charger’s DC detection requirements. Voltage dependence and endurance claims are inconsistent in the source and are excluded.

QUÉ ES W9 GROUP

W9 Group RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCR2-63 enquiry, contact W9 Group about configuration and matching product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

JCR2-63 RCBO Datasheet and Wiring Information

Use W9 Group technical support and the product directory to specify JCR2-63. Request a datasheet and wiring diagram matching the selected JCR2-63 configuration.

Preguntas frecuentes del comprador

JCR2-63 RCBO FAQs for EV Charger Circuit Selection

Find answers about JCR2-63 selection, configuration and ordering.

What protection does JCR2-63 combine?

It combines residual-current protection with overload and short-circuit protection, unlike an RCCB that requires separate overcurrent protection.

Which currents and trip curves can I specify?

The published schedule lists 6, 10, 16, 20, 25, 32, 40, 50 and 63 A, with B or C trip curves. Confirm the complete order code.

Is a 30mA RCBO the only sensitivity option?

No. The catalog also lists 100 mA and 300 mA. Select sensitivity according to the circuit protection requirements and applicable installation rules.

Does a Type A RCBO detect smooth DC residual current?

Do not treat Type A as Type B protection. Confirm the required residual-current waveform coverage and any separate DC detection for the connected equipment.

Can JCR2-63 be specified for an EV charger?

The page markets it for EV charging, but suitability depends on the charger, DC residual-current detection and local installation requirements. Confirm the complete protection arrangement before ordering.

Does this RCBO provide open-PEN protection?

An independent open-PEN protection function is not established by the target-model data. Confirm any required separate device rather than assuming it is included.

What is needed for a JCR2-63 quotation?

Envíe la configuración requerida, la cantidad, el mercado de destino y los requisitos documentales. Solicite a W9 Group que confirme el precio, la cantidad mínima de pedido, las muestras y el plazo de entrega para la configuración seleccionada.

Solicitud de producto

Request a JCR2-63 RCBO Quotation

Tell W9 Group your current, curve, residual-current type, sensitivity, charger details and pole arrangement, quantity and destination market so the selected configuration can be identified.

Contacte a W9 Group