قطعکننده جریان پسزمینهای تکواحدی RCBO با حفاظت از اضافه بار JCB2LE-40M 1P+N، کوچک، 6 کیلو آمپر
اطلاعات فنی
JCB2LE-40M 6kA 1P+N Single Module RCBO Specifications
The JCB2LE-40M single module RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.
|
استاندارد |
IEC61009-1 , EN61009-1 |
|
|
الکترونیک features |
مقاومت جریان ورودی (A) |
6, 10, 16, 20, 25, 32, 40 |
|
نوع |
الکترونیک |
|
|
نوع (فرم موج عبور جریان زمین را حس کردهایم) |
A or AC are available |
|
|
پوشندگان لهستانی |
1P+N |
|
|
فشار ولتاژ Ue (V) |
230/240 |
|
|
Rated sensitivity I△n |
30mA, 100mA,300mA |
|
|
ولتاژ عایق بندی Ui (V) |
500 |
|
|
فراوانی رتبهبندی شده |
۵۰/۶۰ هرتز |
|
|
قدرت شکسته شدن بر اساس رتبه بندی |
6kA |
|
|
Rated impulse withstand voltage(1.2/50) Uimp (V) |
6000 |
|
|
سطح آلودگی |
2 |
|
|
خاصیت آزاد شدن ترمو-مغناطیسی |
B، C |
|
|
ماشینی features |
زندگی الکتریکی |
2, 000 |
|
زمان کارکرد مکانیکی |
20, 000 |
|
|
نمایشگر موقعیت تماس |
بله |
|
|
سطح حفاظت |
IP20 |
|
|
دمای مرجع برای تنظیم عنصر حرارتی (درجه سانتیگراد) |
30 |
|
|
Ambient temperature (with daily average ≤35℃) |
-5…+40 |
|
|
Storage temperation (℃) |
-25…+70 |
|
|
ارائه نصب |
نوع اتصال ترمینال |
Cable/Pin-type busbar |
|
ابعاد بالایی/پایینی ترمینال برای کابل |
16mm2 / 18-5 AWG |
|
|
ابعاد پایانه بالایی/پایینی برای Busbar |
10mm2 / 18-8 AWG |
|
|
تنگ کردن گشتاور |
2.5 N*m / 22 In-Ibs. |
|
|
قرارگیری |
بر روی ریل DIN EN 60715 (35 میلی متر) با استفاده از دستگاه سریع اتصال |
|
|
اتصال |
از بالا یا پایین قابل استفاده هستند |
راهنمای انتخاب
Selecting a 30mA or 100mA RCBO for a DIN Rail Consumer Unit
Specify the rated current, B or C curve, waveform type, residual-current sensitivity, module dimensions and busbar requirements when requesting a JCB2LE-40M quotation from W9 Group.
Check module space
JCB2LE-40M is listed as a single-module 1P+N RCBO. Confirm dimensions and busbar fit for the selected enclosure.
Choose current and curve
Current options from 6 to 40 A and B or C curves are listed. State both fields in the enquiry.
Choose leakage detection
Specify Type A or Type AC and the required 30 mA or 100 mA sensitivity. Confirm the selected combination.
Check connections
Request the cable, busbar and terminal instructions for the selected unit before installation.
درباره W9 Group
W9 Group 1P+N Single Module RCBO Supply and Support
Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-40M order, contact W9 Group about the required configuration and product documents.

منابع مرتبط
JCB2LE-40M 1P+N Single Module RCBO Technical Document Requests
Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-40M configuration.
سوالات متداول خریداران
RCBO FAQs: Module Width, Current and Sensitivity
Find answers about configuration, installation documents and ordering.
What pole arrangement does JCB2LE-40M use?
JCB2LE-40M is listed as a single-module 1P+N RCBO. Confirm live and neutral terminal identification using its wiring diagram.
Which sensitivity options are shown here?
This page lists 30 mA and 100 mA sensitivity options. Ask W9 Group to confirm the required sensitivity and waveform combination for the quoted device.
Which current ratings and trip curves are listed?
JCB2LE-40M lists 6, 10, 16, 20, 25, 32 and 40 A ratings with B or C curves. Confirm the chosen rating and curve on the quotation.
What is needed for a JCB2LE-40M quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.
How do I choose Type A or Type AC for JCB2LE-40M?
Specify the residual-current waveform response required by the load and installation design. Ask W9 Group to confirm the available JCB2LE-40M version and its matching test and wiring documents.
Which JCB2LE-40M busbar and terminal details should I confirm?
Request the selected JCB2LE-40M terminal drawing and confirm the compatible busbar form, conductor connection and tightening instructions before arranging the consumer unit.
How do I check JCB2LE-40M against upstream protective devices?
Provide the installation voltage and prospective fault current, and request the applicable breaking-capacity and coordination data. Confirm the selected current and trip-curve version as part of that check.
سؤال و جواب درباره محصول
Request a JCB2LE-40M 1P+N Single Module RCBO Quotation
Tell W9 Group your rated current, B or C curve, waveform type, residual-current sensitivity, module dimensions and busbar requirements, quantity and destination market so the selected configuration can be identified.