قطعکن جریانِ تصادفی RCBO با حفاظت از جریان بیش از حد و نشت، قطعکن دیفرانسیل JCB2LE-80M دوپین
اطلاعات فنی
JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications
W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards.
| استاندارد | IEC61009-1 , EN61009-1 | |
|---|---|---|
| مقاومت جریان ورودی (A) | 6, 10, 16, 20, 25, 32, 40,50,63,80 | |
| نوع | الکترونیک | |
| Type (wave form of the earth leakage sensed) | A or AC are available | |
| پوشندگان لهستانی | 2 Pole | |
| Rated voltage Ue(V) | 230/240 | |
| Rated sensitivity I△n | 30mA,100mA,300mA are available | |
| ولتاژ عایق بندی Ui (V) | 500 | |
| فراوانی رتبهبندی شده | ۵۰/۶۰ هرتز | |
| قدرت شکسته شدن بر اساس رتبه بندی | 6kA | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 6000 | |
| سطح آلودگی | 2 | |
| خاصیت آزاد شدن ترمو-مغناطیسی | B، C | |
| زندگی الکتریکی | 2, 000 | |
| زمان کارکرد مکانیکی | 10, 000 | |
| نمایشگر موقعیت تماس | بله | |
| سطح حفاظت | IP20 | |
| دمای مرجع برای تنظیم عنصر حرارتی (درجه سانتیگراد) | 30 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperature (℃) | -25…+70 | |
| نوع اتصال ترمینال | کابل/پیوستهای U-type/پیوستهای Pin-type | |
| ابعاد بالایی/پایینی ترمینال برای کابل | 25mm2 / 18-3 AWG | |
| ابعاد پایانه بالایی/پایینی برای Busbar | 10mm2 / 18-8 AWG | |
| تنگ کردن گشتاور | 2.5 N*m / 22 In-Ibs. | |
| قرارگیری | On DIN rail EN 60715 (35mm) by means of fast clip device | |
| اتصال | از بالا یا پایین قابل استفاده هستند | |
راهنمای انتخاب
Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits
Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.
Select the rated current
The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.
Specify leakage protection
Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.
Identify the breaking rating
Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.
Check board connections
The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.
درباره W9 Group
W9 Group 2 Pole Electronic RCBO Supply and Support
Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

منابع مرتبط
JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests
Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.
سوالات متداول خریداران
RCBO FAQs: Trip Curves and Leakage Sensitivity
Find answers about ratings, configuration and ordering.
Is JCB2LE-80M a 2 pole RCBO?
The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.
Is the standard breaking capacity 6 kA or 10 kA?
The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.
Can I specify JCB2LE-80M as a 16 A RCBO?
The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.
What is needed for a JCB2LE-80M quotation?
Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.
سؤال و جواب درباره محصول
Request a JCB2LE-80M 2 Pole Electronic RCBO Quotation
Tell W9 Group your rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection, quantity and destination market so the selected configuration can be identified.