サーキット保護製品

ホーム製品サーキット保護製品RCBORCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole
  • 過電流および漏洩保護機能付き残留電流遮断器 RCBO JCB2LE-80M 2極 ギャラリー画像 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3
  • 過電流および漏洩保護機能付き残留電流遮断器 RCBO JCB2LE-80M 2極 ギャラリー画像 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3

過電流および漏電保護付き残留電流遮断器 RCBO,差動遮断器 JCB2LE-80M 2極

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards. Request the required configuration and matching installation documents from W9 Group.

技術データ

JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards.

JCB2LE-80M specifications
スタンダード IEC61009-1 , EN61009-1
定格電流(A) 6, 10, 16, 20, 25, 32, 40,50,63,80
タイプ 電子機器
Type (wave form of the earth leakage sensed) A or AC are available
ポーランド人 2 Pole
Rated voltage Ue(V) 230/240
Rated sensitivity I△n 30mA,100mA,300mA are available
絶縁電圧 Ui(V) 500
定格周波数 50/60Hz
定格断面積 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
汚染度 2
熱磁性放出特性 B、C
電気寿命 2, 000
機械的寿命 10, 000
接触位置インジケーター はい
保護レベル IP20
サーマルエレメントの設定時の基準温度(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperature (℃) -25…+70
ターミナル接続タイプ ケーブル/U型バスバー/ピン型バスバー
ケーブル用の端末サイズの上部/下部 25mm2 / 18-3 AWG
バスバー用端子サイズの上部/下部 10mm2 / 18-8 AWG
締めトルク 2.5 N*m / 22 In-Ibs.
取り付け On DIN rail EN 60715 (35mm) by means of fast clip device
接続 上部または下部から利用可能です

選定ガイド

Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits

Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.

01

Select the rated current

The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.

02

Specify leakage protection

Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.

03

Identify the breaking rating

Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.

04

Check board connections

The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.

Before specifying JCB2LE-80M: Match rated current, trip curve, residual-current sensitivity and detection type to the circuit requirements. Use the wiring diagram for the selected configuration.

W9 GROUPについて

W9 Group 2 Pole Electronic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.

購入者のよくある質問

RCBO FAQs: Trip Curves and Leakage Sensitivity

Find answers about ratings, configuration and ordering.

Is JCB2LE-80M a 2 pole RCBO?

The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.

Is the standard breaking capacity 6 kA or 10 kA?

The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.

Can I specify JCB2LE-80M as a 16 A RCBO?

The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.

What is needed for a JCB2LE-80M quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

製品のお問い合わせ

Request a JCB2LE-80M 2 Pole Electronic RCBO Quotation

Tell W9 Group your rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ