Circuit Protection Products

HomeProductsCircuit Protection ProductsRCBORCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3

RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards. Request the required configuration and matching installation documents from W9 Group.

TECHNICAL DATA

JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications

W9 Group lists JCB2LE-80M as a two-pole electronic RCBO for residual-current, overload and short-circuit protection in consumer units and distribution boards.

JCB2LE-80M specifications
Standard IEC61009-1 , EN61009-1
Rated current In (A) 6, 10, 16, 20, 25, 32, 40,50,63,80
Type Electronic
Type (wave form of the earth leakage sensed) A or AC are available
Poles 2 Pole
Rated voltage Ue(V) 230/240
Rated sensitivity I△n 30mA,100mA,300mA are available
Insulation voltage Ui (V) 500
Rated frequency 50/60Hz
Rated breaking capacity 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Pollution degree 2
Thermo-magnetic release characteristic B, C
Electrical life 2, 000
Mechanical life 10, 000
Contact position indicator Yes
Protection degree IP20
Reference temperature for setting of thermal element(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperature (℃) -25…+70
Terminal connection type Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable 25mm2 / 18-3 AWG
Terminal size top/bottom for Busbar 10mm2 / 18-8 AWG
Tightening torque 2.5 N*m / 22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top or bottom are available

SELECTION GUIDE

Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits

Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.

01

Select the rated current

The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.

02

Specify leakage protection

Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.

03

Identify the breaking rating

Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.

04

Check board connections

The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.

Before specifying JCB2LE-80M: Match rated current, trip curve, residual-current sensitivity and detection type to the circuit requirements. Use the wiring diagram for the selected configuration.

ABOUT W9 GROUP

W9 Group 2 Pole Electronic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.

BUYER FAQ

RCBO FAQs: Trip Curves and Leakage Sensitivity

Find answers about ratings, configuration and ordering.

Is JCB2LE-80M a 2 pole RCBO?

The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.

Is the standard breaking capacity 6 kA or 10 kA?

The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.

Can I specify JCB2LE-80M as a 16 A RCBO?

The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.

What is needed for a JCB2LE-80M quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

PRODUCT ENQUIRY

Request a JCB2LE-80M 2 Pole Electronic RCBO Quotation

Tell W9 Group your rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection, quantity and destination market so the selected configuration can be identified.

Contact W9 Group