InicioProductosProductos de protección de circuitosRCBORCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole
  • Disjuntor de corriente residual RCBO con protección contra sobrecorriente y fuga, disjuntor diferencial JCB2LE-80M de 2 polos
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3
  • Disjuntor de corriente residual RCBO con protección contra sobrecorriente y fuga, disjuntor diferencial JCB2LE-80M de 2 polos
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3

Disjuntor de corriente residual RCBO con protección contra sobrecorriente y fuga, disjuntor diferencial JCB2LE-80M de 2 polos

The JCB2LE-80M 2 pole RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

DATOS TÉCNICOS

JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications

The JCB2LE-80M 2 pole RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

Estándar

IEC61009-1 ,  EN61009-1

Eléctrico

características

Corriente nominal en A (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Tipo

Electrónico

Tipo (forma de onda de la fuga de tierra detectada)

A or AC are available

Polacos

2 Pole

Tensión nominal Ue (V)

230/240

Rated sensitivity I△n

30mA,100mA,300mA are available

Tensión de aislamiento Ui (V)

500

Frecuencia nominal

50/60Hz

Capacidad de ruptura nominal

6kA

Rated impulse withstand voltage(1.2/50) Uimp (V)

6000

Nivel de contaminación

2

Característica de liberación termomagnética

B, C

Mechanical

características

Vida eléctrica

2, 000

Vida mecánica

10, 000

Indicador de posición de contacto

Sí

Nivel de protección

IP20

Temperatura de referencia para el ajuste del elemento térmico (℃)

30

Ambient temperature (with daily average ≤35℃)

-5…+40

Storage temperation (℃)

-25…+70

Instalación

Tipo de conexión de terminal

Cable/tablero tipo U/tablero tipo pin

Dimensiones del terminal superior/inferior para el cable

25mm2  / 18-3 AWG

Dimensiones terminales superiores/inferiores para la barra de bus

10mm2  / 18-8 AWG

Torque de ajuste

2.5 N*m  /  22 In-Ibs.

Instalación

En el soporte de pared DIN EN 60715 (35 mm) mediante dispositivo de sujeción rápido

Conexión

Están disponibles desde arriba o desde abajo

Guía de selección

Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits

Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.

01

Select the rated current

The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.

02

Specify leakage protection

Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.

03

Identify the breaking rating

Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.

04

Check board connections

The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.

Before specifying JCB2LE-80M: Match rated current, trip curve, residual-current sensitivity and detection type to the circuit requirements. Use the wiring diagram for the selected configuration.

QUÉ ES W9 GROUP

W9 Group 2 Pole Electronic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

Ámbito de aplicación de los productos de protección de circuitos W9 Group para OEM y ODM
Rango de protección contra circuitos de W9 Group — ilustración de la categoría.

RECURSOS RELACIONADOS

JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.

Preguntas frecuentes del comprador

RCBO FAQs: Trip Curves and Leakage Sensitivity

Find answers about ratings, configuration and ordering.

Is JCB2LE-80M a 2 pole RCBO?

The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.

Is the standard breaking capacity 6 kA or 10 kA?

The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.

Can I specify JCB2LE-80M as a 16 A RCBO?

The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.

What is needed for a JCB2LE-80M quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

How should I specify JCB2LE-80M rated current and leakage sensitivity together?

State the load-current rating and residual-current sensitivity as separate selections, together with the waveform type and trip curve. Confirm the available JCB2LE-80M combination on the order-code datasheet.

What should I check for JCB2LE-80M cable or busbar connections?

Request the selected terminal drawing and confirm cable size, busbar form, tightening requirements and connection direction against the board design. Do not infer fit from the two-pole description alone.

Which JCB2LE-80M documents are needed for a consumer-unit layout?

Request the exact-version outline, connection diagram and operating instructions. Confirm the terminal clearance and board space for the selected JCB2LE-80M before installation.