Продукты для защиты от перегрузок

ГлавнаяПродукцияПродукты для защиты от перегрузокRCBORCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole
  • RCBO с тревожным выходом 6 кА, переключатель-блокировщик JCB2LE-80M4P+A с 4 полюсами
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 2
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 3
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 4
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 5
  • RCBO с тревожным выходом 6 кА, переключатель-блокировщик JCB2LE-80M4P+A с 4 полюсами
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 2
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 3
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 4
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 5

RCBO с тревожным выходом 6 кА, переключатель-блокировщик JCB2LE-80M4P+A 4 полюсный

W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB2LE-80M4P+A 6kA 4 Pole RCBO with Alarm Specifications

W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.

Стандартный IEC61009-1 ,  EN61009-1

Электрические характеристики

Максимальный ток в А (А) 6, 10, 16, 20, 25, 32, 40,50,63,80
Тип Eletronic
Тип (форма волны обнаруженного утечка электроэнергии) A or AC are available
Поляки 4 полюса
Номинальное напряжение Ue (V) 230/240
Rated sensitivity I△n 30mA,100mA
Изоляционное напряжение Ui (В) 500
Определенная частота 50/60 Гц
Максимальный пробойной прочность 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Уровень загрязнения 2
Характеристика термомагнитного разрыва B, C

Механические характеристики

Электрическая жизнь 2, 000
Механический срок службы 2, 000
Индикатор положения контакта Да
Степень защиты IP20
Референтная температура для настройки теплового элемента (℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70

Установка

Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25mm2  / 18-4 AWG
Высокоскоростной терминал для разветвления кабелей 10mm2  / 18-8 AWG
Усиление крутящего момента 2.5 N*m  /  22 In-Ibs.
Установка На DIN-рейле EN 60715 (35 мм) с помощью устройства с быстрым зажимом
Вставка Доступны варианты сверху или снизу

ГИД ПО ОТБЕРЕЖЕ

Selecting a 4 Pole RCBO with Alarm and Type A or AC Options

Specify the rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents when requesting a JCB2LE-80M4P+A quotation from W9 Group.

01

Specify the alarm interface

Request the alarm-contact diagram, contact ratings and operating behavior required by the monitoring circuit.

02

Confirm supply voltage

State the circuit's supply voltage and request confirmation of the voltage marked on the selected alarm RCBO.

03

Choose current and curve

The product lists a 6–80 A range with B or C curves. Include the required rating and curve in the enquiry.

04

Specify leakage detection

State the required waveform type and sensitivity. Confirm both for the selected JCB2LE-80M4P+A configuration.

Before specifying JCB2LE-80M4P+A: Confirm operating voltage, residual-current sensitivity and alarm-contact requirements together. Request the JCB2LE-80M4P+A wiring diagram before connecting the monitoring circuit.

О W9 GROUP

W9 Group 4 Pole RCBO with Alarm Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M4P+A order, contact W9 Group about the required configuration and product documents.

Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB2LE-80M4P+A 4 Pole RCBO with Alarm Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M4P+A configuration.

Часто задаваемые вопросы покупателей

RCBO FAQs: Alarm, Current and Sensitivity Checks

Find answers about configuration, installation documents and ordering.

What distinguishes the alarm version?

JCB2LE-80M4P+A is listed as an RCBO with alarm for circuit monitoring. Request the alarm wiring diagram and contact data for the required monitoring interface.

How should voltage and sensitivity be selected?

Provide the supply voltage and required residual-current sensitivity. Ask W9 Group to confirm the ratings for the quoted alarm RCBO before approving the order.

Which current range and trip curves are listed?

The product information lists a 6–80 A range and B or C curves. Confirm the exact current, curve and alarm configuration on the quotation.

What is needed for a JCB2LE-80M4P+A quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

What alarm-contact wiring data is needed for JCB2LE-80M4P+A?

Request the alarm terminal diagram, signal-contact duty and reset sequence for the quoted JCB2LE-80M4P+A. Confirm the external signaling circuit separately from the protected power circuit.

How do I check JCB2LE-80M4P+A fault-duty coordination?

Provide the supply voltage and prospective short-circuit current, then request the breaking-capacity and coordination documents for the exact current and pole configuration.

Which dimensions should I check before fitting the four-pole alarm RCBO?

Request the JCB2LE-80M4P+A outline and connection drawing. Confirm the device width, terminal clearance and alarm-wiring space against the distribution-board layout.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB2LE-80M4P+A 4 Pole RCBO with Alarm Quotation

Tell W9 Group your rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents, quantity and destination market so the selected configuration can be identified.

Свяжитесь с W9 Group