محصولات حفاظت مدار

خانهمحصولاتمحصولات حفاظت مدارRCBORCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole
  • RCBO با کلید ایمنی هشدار دهنده 6 کیلو آمپر، قطع کننده مدار JCB2LE-80M4P+A 4 پین
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 2
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 3
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 4
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 5
  • RCBO با کلید ایمنی هشدار دهنده 6 کیلو آمپر، قطع کننده مدار JCB2LE-80M4P+A 4 پین
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 2
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 3
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 4
  • RCBO With Alarm 6kA Safety Switch Circuit Breaker JCB2LE-80M4P+A 4 Pole Gallery image 5

RCBO با پریز هشدار دهنده 6 کیلو آمپر، قطع کننده مدار JCB2LE-80M4P+A 4 پین

W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.

اطلاعات فنی

JCB2LE-80M4P+A 6kA 4 Pole RCBO with Alarm Specifications

W9 Group lists JCB2LE-80M4P+A as a 4-pole RCBO with alarm for circuit monitoring. The product information describes residual-current, overload and short-circuit protection, a 6 kA breaking capacity and a 6–80 A current range.

استاندارد IEC61009-1 ,  EN61009-1

ویژگی‌های الکتریکی

مقاومت جریان ورودی (A) 6, 10, 16, 20, 25, 32, 40,50,63,80
نوع Eletronic
نوع (فرم موج عبور جریان زمین را حس کرده‌ایم) A or AC are available
پوشندگان لهستانی 4 Pole
فشار ولتاژ Ue (V) 230/240
Rated sensitivity I△n 30mA,100mA
ولتاژ عایق بندی Ui (V) 500
فراوانی رتبهبندی شده ۵۰/۶۰ هرتز
قدرت شکسته شدن بر اساس رتبه بندی 6kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
سطح آلودگی 2
خاصیت آزاد شدن ترمو-مغناطیسی B، C

ویژگی‌های مکانیکی

زندگی الکتریکی 2, 000
زمان کارکرد مکانیکی 2, 000
نمایشگر موقعیت تماس بله
سطح حفاظت IP20
دمای مرجع برای تنظیم عنصر حرارتی (درجه سانتیگراد) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -25…+70

ارائه نصب

نوع اتصال ترمینال کابل/پیوستهای U-type/پیوستهای Pin-type
ابعاد بالایی/پایینی ترمینال برای کابل 25mm2  / 18-4 AWG
ابعاد پایانه بالایی/پایینی برای Busbar 10mm2  / 18-8 AWG
تنگ کردن گشتاور 2.5 N*m  /  22 In-Ibs.
قرارگیری بر روی ریل DIN EN 60715 (35 میلی متر) با استفاده از دستگاه سریع اتصال
اتصال از بالا یا پایین قابل استفاده هستند

راهنمای انتخاب

Selecting a 4 Pole RCBO with Alarm and Type A or AC Options

Specify the rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents when requesting a JCB2LE-80M4P+A quotation from W9 Group.

01

Specify the alarm interface

Request the alarm-contact diagram, contact ratings and operating behavior required by the monitoring circuit.

02

Confirm supply voltage

State the circuit's supply voltage and request confirmation of the voltage marked on the selected alarm RCBO.

03

Choose current and curve

The product lists a 6–80 A range with B or C curves. Include the required rating and curve in the enquiry.

04

Specify leakage detection

State the required waveform type and sensitivity. Confirm both for the selected JCB2LE-80M4P+A configuration.

Before specifying JCB2LE-80M4P+A: Confirm operating voltage, residual-current sensitivity and alarm-contact requirements together. Request the JCB2LE-80M4P+A wiring diagram before connecting the monitoring circuit.

درباره W9 Group

W9 Group 4 Pole RCBO with Alarm Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M4P+A order, contact W9 Group about the required configuration and product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

JCB2LE-80M4P+A 4 Pole RCBO with Alarm Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M4P+A configuration.

سوالات متداول خریداران

RCBO FAQs: Alarm, Current and Sensitivity Checks

Find answers about configuration, installation documents and ordering.

What distinguishes the alarm version?

JCB2LE-80M4P+A is listed as an RCBO with alarm for circuit monitoring. Request the alarm wiring diagram and contact data for the required monitoring interface.

How should voltage and sensitivity be selected?

Provide the supply voltage and required residual-current sensitivity. Ask W9 Group to confirm the ratings for the quoted alarm RCBO before approving the order.

Which current range and trip curves are listed?

The product information lists a 6–80 A range and B or C curves. Confirm the exact current, curve and alarm configuration on the quotation.

What is needed for a JCB2LE-80M4P+A quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

What alarm-contact wiring data is needed for JCB2LE-80M4P+A?

Request the alarm terminal diagram, signal-contact duty and reset sequence for the quoted JCB2LE-80M4P+A. Confirm the external signaling circuit separately from the protected power circuit.

How do I check JCB2LE-80M4P+A fault-duty coordination?

Provide the supply voltage and prospective short-circuit current, then request the breaking-capacity and coordination documents for the exact current and pole configuration.

Which dimensions should I check before fitting the four-pole alarm RCBO?

Request the JCB2LE-80M4P+A outline and connection drawing. Confirm the device width, terminal clearance and alarm-wiring space against the distribution-board layout.

سؤال و جواب درباره محصول

Request a JCB2LE-80M4P+A 4 Pole RCBO with Alarm Quotation

Tell W9 Group your rated current, supply voltage, waveform type, residual-current sensitivity, alarm-contact requirements and wiring documents, quantity and destination market so the selected configuration can be identified.

تماس با گروه W9