JC3RH-S 누전차단기

The JC3RH-S residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JC3RH-S Residual Current Device: Type A / AC, Current and Sensitivity

The JC3RH-S residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation.

표준 IEC61008-1 , EN61008-1
전기 기능 정격 전류(A) 25, 40, 50, 63, 80, 100
형태 전자기력
형태(지하 배수관에서 감지된 파형) AC, A, AC-G, A-G, AC-S and A-S are available
폴란드인 2 Pole, 4 Pole
정격 전압 Ue(V) 230/240 (2P), 400/415(4P)
Rated sensitivity I∆n 30mA,100mA,300mA are available
절연 전압 Ui(V) 500
Rated residual making and breaking capacity I∆m (A) 500 (In=25A/40A), 630 (In=63A),
1000(In=80A/100A)
정격 주파수 50/60Hz
최대 절단 용량 6kA, 10kA
정격 임펄스 내전압(1.2/50) Uimp (V) 6000
Dielectric test voltage at ind. Freq. for 1 min 2.5kV
오염 정도 2
기계적 특징 전기 수명 2, 000
기계적 수명 2, 000
접촉 위치 표시기 네
보호 수준 IP20
Reference temperature for setting of thermal
element(°C)
30
Ambient temperature (with daily average ≤35°C) -5…+40
Storage temperature (°C) -25…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2 , 18-3/18-2 AWG
버스바용 터미널 사이즈 상단/하단 10/16mm2 ,18-8 /18-5AWG
강력한 토크 2.5 N*m / 22 In-Ibs.
장착 On DIN rail EN 60715 (35mm)
연결 From top or bottom

선정 가이드

How to Select a JC3RH-S 2 Pole or 4 Pole RCD for Earth-Leakage Protection

Specify the waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection when requesting a JC3RH-S quotation from W9 Group.

01

Choose the residual waveform type

Specify Type A or Type AC according to the connected equipment and installation rules. Confirm the exact suffix and response characteristics.

02

Separate current from sensitivity

Select the load-current rating and residual-current sensitivity independently. Confirm the protective purpose and coordination of the chosen sensitivity.

03

Match the poles and supply

Use the published pole-specific voltage options and request the neutral-terminal and supply-connection drawing for the exact version.

04

Coordinate backup protection

Request the conditional short-circuit data and associated upstream device. Confirm selectivity using trip-time information instead of relying on a suffix alone.

Before specifying JC3RH-S: Confirm the waveform type, poles, sensitivity, any delay characteristics and the associated overcurrent protective device. Obtain matching compliance and coordination documents.

W9 그룹 소개

W9 Group JC3RH-S Residual Current Device Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH-S enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JC3RH-S RCD Wiring, Trip-Time and Backup-Protection Documents

Use technical support and related products to specify JC3RH-S. Request a datasheet and wiring diagram matching the selected JC3RH-S configuration.

구매자 FAQ

JC3RH-S RCD FAQs: Type A vs AC, Sensitivity and Overcurrent Coordination

Find answers about JC3RH-S selection, configuration and ordering.

What does the JC3RH-S residual current device protect against?

Its stated function is earth-leakage protection. The source cites the residual-current device standard; the candidate does not claim integrated overload or short-circuit tripping from contradictory legacy wording.

Which load-current and sensitivity options are listed?

The target table lists 25, 40, 50, 63, 80 and 100 A, with 30 mA, 100 mA and 300 mA residual-current sensitivity options. Confirm the exact offered combination.

How do I choose Type A or Type AC?

Select the waveform response required for the connected load and local installation rules. Confirm the full device type from a matching datasheet; Type A is not an assumed smooth-DC detection rating.

What are the pole and operating-voltage options?

The table lists 2-pole versions at 230/240 V and 4-pole versions at 400/415 V. Confirm the supplied pole version, neutral terminals and wiring diagram.

Does the S suffix prove time-delayed selective operation?

The schedule lists several waveform and suffix variants but does not establish the exact time-current behavior of every listing. Confirm the delay class, trip-time curve and upstream/downstream coordination.

Does it replace an MCB or other overcurrent protective device?

Residual-current protection and overcurrent protection serve different duties. Confirm the separate overload and short-circuit device and the tested backup combination for the installation.

What is needed for a JC3RH-S quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JC3RH-S Residual Current Device Quotation

Tell W9 Group your waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection, quantity and destination market so the selected configuration can be identified.