Residual Current Device JC3RH-S

Características
● Electromagnetic Type
● Earth leakage protection
● Breaking capacity 6kA, or 10kA
● Rated current up to 100A
● Available in Type A or Type AC
● Tripping sensitivity: 30mA,100mA,300mA
● Connection from top or bottom
● Complies with IEC 61008-1, EN61008-1
Solicitud
The JC3RH-S RCD (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.
Overall, the JCSD1-125 is a must-have accessory for anyone looking to increase the safety and efficiency of their electrical installations. Its intuitive design, rugged construction and compliance with industry standards make it an excellent solution for MCB and RCBO monitoring. With the JCSD1-125, users can control their circuits with confidence knowing they have a reliable and effective tool.
| Estándar | IEC61008-1 , EN61008-1 | |
| Características eléctricas | Corriente nominal en A (A) | 25, 40, 50, 63, 80, 100 |
| Tipo | Electromagnetic | |
| Type (wave form of the earth leakage sensed) | AC, A, AC-G, A-G, AC-S and A-S are available | |
| Polacos | 2 Pole, 4 Pole | |
| Rated voltage Ue(V) | 230/240 (2P), 400/415(4P) | |
| Rated sensitivity I∆n | 30mA,100mA,300mA are available | |
| Tensión de aislamiento Ui (V) | 500 | |
| Rated residual making and breaking capacity I∆m (A) |
500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A) |
|
| Frecuencia nominal | 50/60Hz | |
| Capacidad de ruptura nominal | 6kA, 10kA | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 6000 | |
| Dielectric test voltage at ind. Freq. for 1 min | 2.5kV | |
| Nivel de contaminación | 2 | |
| Características mecánicas | Vida eléctrica | 2, 000 |
| Vida mecánica | 2, 000 | |
| Indicador de posición de contacto | Sí | |
| Nivel de protección | IP20 | |
|
Reference temperature for setting of thermal element(°C) |
30 | |
| Ambient temperature (with daily average ≤35°C) | -5…+40 | |
| Storage temperature (°C) | -25…+70 | |
| Instalación | Tipo de conexión de terminal | Cable/tablero tipo U/tablero tipo pin |
| Dimensiones del terminal superior/inferior para el cable | 25mm2 , 18-3/18-2 AWG | |
| Dimensiones terminales superiores/inferiores para la barra de bus | 10/16mm2 ,18-8 /18-5AWG | |
| Torque de ajuste | 2.5 N*m / 22 In-Ibs. | |
| Instalación | On DIN rail EN 60715 (35mm) | |
| Conexión | From top or bottom |