Dispositivo de corriente residual JC3RH
DATOS TÉCNICOS
JC3RH Residual Current Device: Type A / AC, Current and Sensitivity
The JC3RH residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation.
| Estándar | IEC61008-1 , EN61008-1 | |
| Características eléctricas | Corriente nominal en A (A) | 25, 40, 50, 63, 80, 100 |
| Tipo | Electromagnetic | |
| Tipo (forma de onda de la fuga de tierra detectada) | AC, A, AC-G, A-G, AC-S and A-S are available | |
| Polacos | 2 Pole, 4 Pole | |
| Tensión nominal Ue (V) | 230/240 (2P), 400/415(4P) | |
| Rated sensitivity I∆n | 30mA,100mA,300mA are available | |
| Tensión de aislamiento Ui (V) | 500 | |
| Rated residual making and breaking capacity I∆m (A) |
500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A) |
|
| Frecuencia nominal | 50/60Hz | |
| Capacidad de ruptura nominal | 6kA, 10kA | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 6000 | |
| Dielectric test voltage at ind. Freq. for 1 min | 2.5kV | |
| Nivel de contaminación | 2 | |
| Características mecánicas | Vida eléctrica | 2, 000 |
| Vida mecánica | 2, 000 | |
| Indicador de posición de contacto | Sí | |
| Nivel de protección | IP20 | |
|
Reference temperature for setting of thermal element(°C) |
30 | |
| Ambient temperature (with daily average ≤35°C) | -5…+40 | |
| Storage temperature (°C) | -25…+70 | |
| Instalación | Tipo de conexión de terminal | Cable/tablero tipo U/tablero tipo pin |
| Dimensiones del terminal superior/inferior para el cable | 25mm2 , 18-3/18-2 AWG | |
| Dimensiones terminales superiores/inferiores para la barra de bus | 10/16mm2 ,18-8 /18-5AWG | |
| Torque de ajuste | 2.5 N*m / 22 In-Ibs. | |
| Instalación | On DIN rail EN 60715 (35mm) | |
| Conexión | From top or bottom |
Guía de selección
How to Select a JC3RH 2 Pole or 4 Pole RCD for Earth-Leakage Protection
Specify the waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection when requesting a JC3RH quotation from W9 Group.
Choose the residual waveform type
Specify Type A or Type AC according to the connected equipment and installation rules. Confirm the exact suffix and response characteristics.
Separate current from sensitivity
Select the load-current rating and residual-current sensitivity independently. Confirm the protective purpose and coordination of the chosen sensitivity.
Match the poles and supply
Use the published pole-specific voltage options and request the neutral-terminal and supply-connection drawing for the exact version.
Coordinate backup protection
Request the conditional short-circuit data and associated upstream device. Confirm selectivity using trip-time information instead of relying on a suffix alone.
QUÉ ES W9 GROUP
W9 Group JC3RH Residual Current Device Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH enquiry, contact W9 Group about configuration and matching product documents.

RECURSOS RELACIONADOS
JC3RH RCD Wiring, Trip-Time and Backup-Protection Documents
Use technical support and related products to specify JC3RH. Request a datasheet and wiring diagram matching the selected JC3RH configuration.
PRODUCTO RELACIONADOJC3RH-SCompare función y configuración; solicite calificaciones separadas para cada modelo
DOCUMENTOSCentro de descarga de W9 GroupRequest the current document for your quoted JC3RH variant
Preguntas frecuentes del comprador
JC3RH RCD FAQs: Type A vs AC, Sensitivity and Overcurrent Coordination
Find answers about JC3RH selection, configuration and ordering.
What does the JC3RH residual current device protect against?
Its stated function is earth-leakage protection. The source cites the residual-current device standard; the candidate does not claim integrated overload or short-circuit tripping from contradictory legacy wording.
Which load-current and sensitivity options are listed?
The target table lists 25, 40, 50, 63, 80 and 100 A, with 30 mA, 100 mA and 300 mA residual-current sensitivity options. Confirm the exact offered combination.
How do I choose Type A or Type AC?
Select the waveform response required for the connected load and local installation rules. Confirm the full device type from a matching datasheet; Type A is not an assumed smooth-DC detection rating.
What are the pole and operating-voltage options?
The table lists 2-pole versions at 230/240 V and 4-pole versions at 400/415 V. Confirm the supplied pole version, neutral terminals and wiring diagram.
Does the S suffix prove time-delayed selective operation?
The schedule lists several waveform and suffix variants but does not establish the exact time-current behavior of every listing. Confirm the delay class, trip-time curve and upstream/downstream coordination.
Does it replace an MCB or other overcurrent protective device?
Residual-current protection and overcurrent protection serve different duties. Confirm the separate overload and short-circuit device and the tested backup combination for the installation.