JC3RH residual current device
TECHNICAL DATA
JC3RH Residual Current Device: Type A / AC, Current and Sensitivity
The JC3RH residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation.
| Standard | IEC61008-1 , EN61008-1 | |
| Electrical features | Rated current In (A) | 25, 40, 50, 63, 80, 100 |
| Type | Electromagnetic | |
| Type (wave form of the earth leakage sensed) | AC, A, AC-G, A-G, AC-S and A-S are available | |
| Poles | 2 Pole, 4 Pole | |
| Rated voltage Ue(V) | 230/240 (2P), 400/415(4P) | |
| Rated sensitivity I∆n | 30mA,100mA,300mA are available | |
| Insulation voltage Ui (V) | 500 | |
| Rated residual making and breaking capacity I∆m (A) |
500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A) |
|
| Rated frequency | 50/60Hz | |
| Rated breaking capacity | 6kA, 10kA | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 6000 | |
| Dielectric test voltage at ind. Freq. for 1 min | 2.5kV | |
| Pollution degree | 2 | |
| Mechanical features | Electrical life | 2, 000 |
| Mechanical life | 2, 000 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
|
Reference temperature for setting of thermal element(°C) |
30 | |
| Ambient temperature (with daily average ≤35°C) | -5…+40 | |
| Storage temperature (°C) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25mm2 , 18-3/18-2 AWG | |
| Terminal size top/bottom for Busbar | 10/16mm2 ,18-8 /18-5AWG | |
| Tightening torque | 2.5 N*m / 22 In-Ibs. | |
| Mounting | On DIN rail EN 60715 (35mm) | |
| Connection | From top or bottom |
SELECTION GUIDE
How to Select a JC3RH 2 Pole or 4 Pole RCD for Earth-Leakage Protection
Specify the waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection when requesting a JC3RH quotation from W9 Group.
Choose the residual waveform type
Specify Type A or Type AC according to the connected equipment and installation rules. Confirm the exact suffix and response characteristics.
Separate current from sensitivity
Select the load-current rating and residual-current sensitivity independently. Confirm the protective purpose and coordination of the chosen sensitivity.
Match the poles and supply
Use the published pole-specific voltage options and request the neutral-terminal and supply-connection drawing for the exact version.
Coordinate backup protection
Request the conditional short-circuit data and associated upstream device. Confirm selectivity using trip-time information instead of relying on a suffix alone.
ABOUT W9 GROUP
W9 Group JC3RH Residual Current Device Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH enquiry, contact W9 Group about configuration and matching product documents.

RELATED RESOURCES
JC3RH RCD Wiring, Trip-Time and Backup-Protection Documents
Use technical support and related products to specify JC3RH. Request a datasheet and wiring diagram matching the selected JC3RH configuration.
RELATED PRODUCTJC3RH-SCompare function and configuration; request separate model ratings
DOCUMENTSW9 Group download centreRequest the current document for your quoted JC3RH variant
BUYER FAQ
JC3RH RCD FAQs: Type A vs AC, Sensitivity and Overcurrent Coordination
Find answers about JC3RH selection, configuration and ordering.
What does the JC3RH residual current device protect against?
Its stated function is earth-leakage protection. The source cites the residual-current device standard; the candidate does not claim integrated overload or short-circuit tripping from contradictory legacy wording.
Which load-current and sensitivity options are listed?
The target table lists 25, 40, 50, 63, 80 and 100 A, with 30 mA, 100 mA and 300 mA residual-current sensitivity options. Confirm the exact offered combination.
How do I choose Type A or Type AC?
Select the waveform response required for the connected load and local installation rules. Confirm the full device type from a matching datasheet; Type A is not an assumed smooth-DC detection rating.
What are the pole and operating-voltage options?
The table lists 2-pole versions at 230/240 V and 4-pole versions at 400/415 V. Confirm the supplied pole version, neutral terminals and wiring diagram.
Does the S suffix prove time-delayed selective operation?
The schedule lists several waveform and suffix variants but does not establish the exact time-current behavior of every listing. Confirm the delay class, trip-time curve and upstream/downstream coordination.
Does it replace an MCB or other overcurrent protective device?
Residual-current protection and overcurrent protection serve different duties. Confirm the separate overload and short-circuit device and the tested backup combination for the installation.
What is needed for a JC3RH quotation?
Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.
PRODUCT ENQUIRY
Request a JC3RH Residual Current Device Quotation
Tell W9 Group your waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection, quantity and destination market so the selected configuration can be identified.