JC3R-125 residual current device

The JC3R-125 residual current device is listed by W9 Group for residual-current protection. Choose the waveform response, sensitivity, current-carrying rating and pole arrangement separately. Coordinate separate overload and short-circuit protection rather than treating an RCD as an RCBO. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

JC3R-125 residual current device specifications

The JC3R-125 residual current device is listed by W9 Group for residual-current protection. Choose the waveform response, sensitivity, current-carrying rating and pole arrangement separately. Coordinate separate overload and short-circuit protection rather than treating an RCD as an RCBO.

Standard IEC61008-1, EN61008-1
Electronic features Rated current In (A) 25, 40, 50, 63, 80, 100, 125
Type Electromagnetic
Type(wave form of the leakage sensed) AC, A, AC-G, A-G AC-S and A-S are available
Poles 3P+N
Rated voltage Ue (V) 3P+N: 400/415
Rated sensitivity IΔn 30mA, 100mA, 300mA are available
Insulation voltage Ui (V) 500
Rated residual making and breaking capacity IΔm 500(In=25/40A), 630(In=63A), 1000(In=80/100A)
Rated frequency 50/60Hz
Rated breaking capacity 6KA, 10KA
Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
Dielectric test voltage at ind.Freq. for 1 min (KV) 2.5
Pollution degree 2
Mechanical features Electrical life 2,000
Mechanical life 4,000
Contact position indicator Yes
Protection degree IP20
Reference temperature for setting of thermal element(℃) 30
Ambient temperature(with daily average ≤35℃) -5…+40
Storage temperature(℃) -25…+70
Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
Terminal size top/bottom for cable 25mm2/18-3AWG
Terminal size top/bottom for Busbar 10mm2/18-8AWG
Tightening torque 2.5N*m/22In-lbs
Mounting On DIN rail EN 60715(35mm)
Connection From top or bottom are available

SELECTION GUIDE

JC3R-125 RCD waveform response selection

Specify the complete order code, circuit duty, installation conditions and required documents when requesting a JC3R-125 quotation from W9 Group.

01

Choose the waveform response

Specify the connected equipment and expected residual-current waveform. Confirm the exact response type and any delay suffix.

02

Coordinate sensitivity and rated current

Choose the required residual-current threshold separately from the current-carrying rating. Confirm both in the ordered version.

03

Coordinate upstream protection

Request the manufacturer’s backup overcurrent and short-circuit coordination requirements for the actual supply and prospective fault level.

04

Plan neutral and test wiring

Request the exact line, neutral and test-circuit diagram. Confirm pole configuration, supply terminals and enclosure integration.

Before specifying JC3R-125: Confirm residual-current type, sensitivity, ordered current, pole diagram and backup protective-device coordination.

ABOUT W9 GROUP

W9 Group support for JC3R-125 RCD

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3R-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

JC3R-125 RCD neutral connection documents

Use technical support and related products to specify JC3R-125. Request a datasheet and wiring diagram matching the selected JC3R-125 configuration.

BUYER FAQ

JC3R-125 RCD overcurrent coordination FAQs

Find answers about JC3R-125 selection, configuration and ordering.

Does this RCD provide overload protection?

A residual-current device is not a substitute for overcurrent protection. Confirm the required upstream protective device and coordination schedule for the selected version.

How do Type A and Type AC differ?

Type AC addresses sinusoidal AC residual current; Type A additionally addresses pulsating DC residual current within its specified scope. Confirm the type required by the connected equipment; neither label establishes Type B coverage.

Are rated current and residual-current sensitivity the same?

No. Rated current concerns the device’s current-carrying duty, while sensitivity concerns its residual-current operating threshold. Confirm each independently in the offered version.

Which pole arrangement is listed?

The original table lists 3P+N at 400/415V. Confirm the neutral and test-circuit wiring, especially for a circuit without a neutral.

Can I use the RCD without a neutral connection?

Request an approved wiring arrangement for the exact unit and supply. Test-circuit operation may depend on the connection; do not improvise resistors or transfer another model’s diagram.

What do the G and S suffixes establish?

The original schedule includes G and S suffix variants. Confirm the actual delay, selectivity and waveform characteristics from the exact version’s documentation before coordinating upstream and downstream devices.

What is needed for a JC3R-125 quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.