Обогреватель JC3RH с рецидивным током

The JC3RH residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JC3RH Residual Current Device: Type A / AC, Current and Sensitivity

The JC3RH residual current device is listed by W9 Group for earth-leakage protection in consumer units and distribution boards. The target schedule offers electromagnetic operation, Type A or Type AC configurations, 2-pole or 4-pole versions and several current and sensitivity choices. Select the exact waveform type and coordinate separate overcurrent protection for the installation.

Стандартный IEC61008-1 , EN61008-1
Электрические характеристики Максимальный ток в А (А) 25, 40, 50, 63, 80, 100
Тип Электромагнитный
Тип (форма волны обнаруженного утечка электроэнергии) AC, A, AC-G, A-G, AC-S and A-S are available
Поляки 2 Pole, 4 Pole
Номинальное напряжение Ue (V) 230/240 (2P), 400/415(4P)
Rated sensitivity I∆n 30mA,100mA,300mA are available
Изоляционное напряжение Ui (В) 500
Rated residual making and breaking capacity I∆m (A) 500 (In=25A/40A), 630 (In=63A),
1000(In=80A/100A)
Определенная частота 50/60 Гц
Максимальный пробойной прочность 6kA, 10kA
Rated impulse withstand voltage(1.2/50) Uimp (V) 6000
Dielectric test voltage at ind. Freq. for 1 min 2.5kV
Уровень загрязнения 2
Механические характеристики Электрическая жизнь 2, 000
Механический срок службы 2, 000
Индикатор положения контакта Да
Степень защиты IP20
Reference temperature for setting of thermal
element(°C)
30
Ambient temperature (with daily average ≤35°C) -5…+40
Storage temperature (°C) -25…+70
Установка Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25mm2 , 18-3/18-2 AWG
Высокоскоростной терминал для разветвления кабелей 10/16mm2 ,18-8 /18-5AWG
Усиление крутящего момента 2.5 N*m / 22 In-Ibs.
Установка On DIN rail EN 60715 (35mm)
Вставка From top or bottom

ГИД ПО ОТБЕРЕЖЕ

How to Select a JC3RH 2 Pole or 4 Pole RCD for Earth-Leakage Protection

Specify the waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection when requesting a JC3RH quotation from W9 Group.

01

Choose the residual waveform type

Specify Type A or Type AC according to the connected equipment and installation rules. Confirm the exact suffix and response characteristics.

02

Separate current from sensitivity

Select the load-current rating and residual-current sensitivity independently. Confirm the protective purpose and coordination of the chosen sensitivity.

03

Match the poles and supply

Use the published pole-specific voltage options and request the neutral-terminal and supply-connection drawing for the exact version.

04

Coordinate backup protection

Request the conditional short-circuit data and associated upstream device. Confirm selectivity using trip-time information instead of relying on a suffix alone.

Before specifying JC3RH: Confirm the waveform type, poles, sensitivity, any delay characteristics and the associated overcurrent protective device. Obtain matching compliance and coordination documents.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JC3RH RCD Wiring, Trip-Time and Backup-Protection Documents

Use technical support and related products to specify JC3RH. Request a datasheet and wiring diagram matching the selected JC3RH configuration.

Часто задаваемые вопросы покупателей

JC3RH RCD FAQs: Type A vs AC, Sensitivity and Overcurrent Coordination

Find answers about JC3RH selection, configuration and ordering.

What does the JC3RH residual current device protect against?

Its stated function is earth-leakage protection. The source cites the residual-current device standard; the candidate does not claim integrated overload or short-circuit tripping from contradictory legacy wording.

Which load-current and sensitivity options are listed?

The target table lists 25, 40, 50, 63, 80 and 100 A, with 30 mA, 100 mA and 300 mA residual-current sensitivity options. Confirm the exact offered combination.

How do I choose Type A or Type AC?

Select the waveform response required for the connected load and local installation rules. Confirm the full device type from a matching datasheet; Type A is not an assumed smooth-DC detection rating.

What are the pole and operating-voltage options?

The table lists 2-pole versions at 230/240 V and 4-pole versions at 400/415 V. Confirm the supplied pole version, neutral terminals and wiring diagram.

Does the S suffix prove time-delayed selective operation?

The schedule lists several waveform and suffix variants but does not establish the exact time-current behavior of every listing. Confirm the delay class, trip-time curve and upstream/downstream coordination.

Does it replace an MCB or other overcurrent protective device?

Residual-current protection and overcurrent protection serve different duties. Confirm the separate overload and short-circuit device and the tested backup combination for the installation.

What is needed for a JC3RH quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JC3RH Residual Current Device Quotation

Tell W9 Group your waveform type, pole arrangement, rated current, sensitivity, supply voltage and backup protection, quantity and destination market so the selected configuration can be identified.