Продукты для защиты от перегрузок

  • Галерея изображений устройств защиты от перегрузок JC3RS-EV Image 1
  • JC3RS-EV Residual Current Device Gallery image 2
  • JC3RS-EV Residual Current Device Gallery image 3
  • JC3RS-EV Residual Current Device Gallery image 4
  • JC3RS-EV Residual Current Device Gallery image 5
  • JC3RS-EV Residual Current Device Gallery image 6
  • Галерея изображений устройств защиты от перегрузок JC3RS-EV Image 1
  • JC3RS-EV Residual Current Device Gallery image 2
  • JC3RS-EV Residual Current Device Gallery image 3
  • JC3RS-EV Residual Current Device Gallery image 4
  • JC3RS-EV Residual Current Device Gallery image 5
  • JC3RS-EV Residual Current Device Gallery image 6

JC3RS-EV — устройство для защиты от перегрузок

JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JC3RS-EV Residual Current Device Product Information

JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.

The older summary and retained original table differ in sensitivity, current options and standards references. Confirm each operating threshold with its unit and the exact protection functions before installation.

Стандартный IEC61009-1, IEC62955
Электрические характеристики Тип (волны от утечки электроэнергии, обнаруженной на земле) EV(A+DC leakage current)
Максимальный ток в А (А) 40, 63
Поляки 1P+N, 3P+N
Номинальное напряжение Ue (В) 1P+N: 230/240 3P+N: 400/415
Определенная чувствительность IΔn 0.03mA
DC tripping threshold IΔdc 6mA
Изоляционное напряжение Ui (В) 500
Rated residual making and breaking capacity IΔm 500(In=25A/40A), 630(In=63A)
Определенная частота 50Hz
Максимальный пробойной прочность 10KA
SCPD fuse 10000A
Break time under IΔn ≤0.1s
Определенная напряженность импульса (1,2/50) Uimp (В) 4,000
Теплопроводящий тест напряжения при индуктивном частотном режиме в течение 1 минуты (КВ) 2.5
Уровень загрязнения 2
Механические характеристики Электрическая жизнь 2,000
Механический срок службы 4,000
Индикатор положения контакта Да
Степень защиты IP20
Референтная температура для настройки теплового элемента (℃) 30
Ambient temperature(with daily average ≤35℃) -5…+40
Storage temperature(℃) -25…+70
Установка Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25mm2/18-3AWG
Terminal size top/bottom for Busbar 10mm2/18-8AWG
Усиление крутящего момента 2.5N*m/22In-lbs
Установка На DIN-рейле EN 60715 (35 мм)
Вставка From top or bottom are available

ГИД ПО ОТБЕРЕЖЕ

Selecting JC3RS-EV residual current device for Your Installation

Use JC3RS-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Choose the waveform response

Specify the connected equipment and expected residual-current waveform. Confirm the exact response type and any delay suffix.

02

Coordinate sensitivity and rated current

Choose the required residual-current threshold separately from the current-carrying rating. Confirm both in the ordered version.

03

Coordinate upstream protection

Request the manufacturer’s backup overcurrent and short-circuit coordination requirements for the actual supply and prospective fault level.

04

Plan neutral and test wiring

Request the exact line, neutral and test-circuit diagram. Confirm pole configuration, supply terminals and enclosure integration.

Before specifying JC3RS-EV: Confirm AC and DC operating thresholds with units, protection identity, current options and matching wiring documentation.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

Request JC3RS-EV Residual Current Device Wiring and Response Data

Use technical support and related products to specify JC3RS-EV. Request a datasheet and wiring diagram matching the selected JC3RS-EV configuration.

Часто задаваемые вопросы покупателей

JC3RS-EV RCD Waveform, Sensitivity and Wiring FAQs

Find answers about JC3RS-EV selection, configuration and ordering.

What does the JC3RS-EV product title identify?

W9 Group lists JC3RS-EV as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.

How do I confirm the JC3RS-EV residual-current waveform response?

Request the JC3RS-EV waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.

How should I specify JC3RS-EV sensitivity and rated current?

Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-EV order-code schedule.

Does JC3RS-EV include overload and short-circuit protection?

Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.

Which JC3RS-EV wiring diagram should I request?

Request the JC3RS-EV line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.

Can JC3RS-EV be specified for a charging circuit?

Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-EV and any separate protective devices meet that specific design.

What should I send for a JC3RS-EV quotation?

Send the complete JC3RS-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3RS-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3RS-EV Pricing and Technical Documents

Пожалуйста, сообщите компании W9 Group свой полный номер заказа, информацию о схеме подключения, условиях установки и необходимых документах, количество и место назначения рынка, чтобы можно было идентифицировать выбранную конфигурацию.

Свяжитесь с W9 Group