ТЕХНИЧЕСКИЕ ДАННЫЕ
JC3RS-EV Residual Current Device Product Information
JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.
The older summary and retained original table differ in sensitivity, current options and standards references. Confirm each operating threshold with its unit and the exact protection functions before installation.
| Стандартный | IEC61009-1, IEC62955 | |
| Электрические характеристики | Тип (волны от утечки электроэнергии, обнаруженной на земле) | EV(A+DC leakage current) |
| Максимальный ток в А (А) | 40, 63 | |
| Поляки | 1P+N, 3P+N | |
| Номинальное напряжение Ue (В) | 1P+N: 230/240 3P+N: 400/415 | |
| Определенная чувствительность IΔn | 0.03mA | |
| DC tripping threshold IΔdc | 6mA | |
| Изоляционное напряжение Ui (В) | 500 | |
| Rated residual making and breaking capacity IΔm | 500(In=25A/40A), 630(In=63A) | |
| Определенная частота | 50Hz | |
| Максимальный пробойной прочность | 10KA | |
| SCPD fuse | 10000A | |
| Break time under IΔn | ≤0.1s | |
| Определенная напряженность импульса (1,2/50) Uimp (В) | 4,000 | |
| Теплопроводящий тест напряжения при индуктивном частотном режиме в течение 1 минуты (КВ) | 2.5 | |
| Уровень загрязнения | 2 | |
| Механические характеристики | Электрическая жизнь | 2,000 |
| Механический срок службы | 4,000 | |
| Индикатор положения контакта | Да | |
| Степень защиты | IP20 | |
| Референтная температура для настройки теплового элемента (℃) | 30 | |
| Ambient temperature(with daily average ≤35℃) | -5…+40 | |
| Storage temperature(℃) | -25…+70 | |
| Установка | Тип терминального соединения | Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками |
| Верхний и нижний размер терминала для кабеля | 25mm2/18-3AWG | |
| Terminal size top/bottom for Busbar | 10mm2/18-8AWG | |
| Усиление крутящего момента | 2.5N*m/22In-lbs | |
| Установка | На DIN-рейле EN 60715 (35 мм) | |
| Вставка | From top or bottom are available |
ГИД ПО ОТБЕРЕЖЕ
Selecting JC3RS-EV residual current device for Your Installation
Use JC3RS-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
Choose the waveform response
Specify the connected equipment and expected residual-current waveform. Confirm the exact response type and any delay suffix.
Coordinate sensitivity and rated current
Choose the required residual-current threshold separately from the current-carrying rating. Confirm both in the ordered version.
Coordinate upstream protection
Request the manufacturer’s backup overcurrent and short-circuit coordination requirements for the actual supply and prospective fault level.
Plan neutral and test wiring
Request the exact line, neutral and test-circuit diagram. Confirm pole configuration, supply terminals and enclosure integration.
О W9 GROUP
W9 Group Support for JC3RS-EV Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-EV enquiry, contact W9 Group about configuration and matching product documents.

СВЯЗАННЫЕ РЕСУРСЫ
Request JC3RS-EV Residual Current Device Wiring and Response Data
Use technical support and related products to specify JC3RS-EV. Request a datasheet and wiring diagram matching the selected JC3RS-EV configuration.
СВЯЗАННЫЕ ПРОДУКТЫJC3RH-EVСравните функциональность и конфигурацию; запросите отдельную оценку модели
ДОКУМЕНТЫЦентр загрузки программ W9 GroupRequest the current document for your quoted JC3RS-EV variant
Часто задаваемые вопросы покупателей
JC3RS-EV RCD Waveform, Sensitivity and Wiring FAQs
Find answers about JC3RS-EV selection, configuration and ordering.
What does the JC3RS-EV product title identify?
W9 Group lists JC3RS-EV as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.
How do I confirm the JC3RS-EV residual-current waveform response?
Request the JC3RS-EV waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.
How should I specify JC3RS-EV sensitivity and rated current?
Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-EV order-code schedule.
Does JC3RS-EV include overload and short-circuit protection?
Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.
Which JC3RS-EV wiring diagram should I request?
Request the JC3RS-EV line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.
Can JC3RS-EV be specified for a charging circuit?
Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-EV and any separate protective devices meet that specific design.
What should I send for a JC3RS-EV quotation?
Send the complete JC3RS-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete JC3RS-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request JC3RS-EV Pricing and Technical Documents
Пожалуйста, сообщите компании W9 Group свой полный номер заказа, информацию о схеме подключения, условиях установки и необходимых документах, количество и место назначения рынка, чтобы можно было идентифицировать выбранную конфигурацию.