JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.
The older summary and retained original table differ in sensitivity, current options and standards references. Confirm each operating threshold with its unit and the exact protection functions before installation.
| スタンダード | IEC61009-1, IEC62955 | |
| 電気機能 | タイプ(地球の漏れを検知した波の形式) | EV(A+DC leakage current) |
| 定格電流(A) | 40, 63 | |
| ポーランド人 | 1P+N, 3P+N | |
| 定格電圧 Ue(V) | 1P+N: 230/240 3P+N: 400/415 | |
| 評価感度 IΔn | 0.03mA | |
| DC tripping threshold IΔdc | 6mA | |
| 絶縁電圧 Ui(V) | 500 | |
| Rated residual making and breaking capacity IΔm | 500(In=25A/40A), 630(In=63A) | |
| 定格周波数 | 50Hz | |
| 定格断面積 | 10KA | |
| SCPD fuse | 10000A | |
| Break time under IΔn | ≤0.1s | |
| 定格インパルス耐圧(1.2/50)Uimp(V) | 4,000 | |
| インダクタンス試験電圧(1分間、KV) | 2.5 | |
| 汚染度 | 2 | |
| 機械的特徴 | 電気寿命 | 2,000 |
| 機械的寿命 | 4,000 | |
| 接触位置インジケーター | はい | |
| 保護レベル | IP20 | |
| サーマルエレメントの設定時の基準温度(℃) | 30 | |
| 周囲温度(1日の平均が35℃以下) | -5…+40 | |
| 保管温度(℃) | -25…+70 | |
| インストール | ターミナル接続タイプ | ケーブル/U型バスバー/ピン型バスバー |
| ケーブル用の端末サイズの上部/下部 | 25mm2/18-3AWG | |
| バスバー用端子サイズの上部/下部 | 10mm2/18-8AWG | |
| 締めトルク | 2.5N*m/22インチ-lbs | |
| 取り付け | DINレール用 EN 60715(35mm) | |
| 接続 | 上部または下部から利用可能です |
選定ガイド
Selecting JC3RS-EV residual current device for Your Installation
Use JC3RS-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
Choose the waveform response
Specify the connected equipment and expected residual-current waveform. Confirm the exact response type and any delay suffix.
Coordinate sensitivity and rated current
Choose the required residual-current threshold separately from the current-carrying rating. Confirm both in the ordered version.
Coordinate upstream protection
Request the manufacturer’s backup overcurrent and short-circuit coordination requirements for the actual supply and prospective fault level.
Plan neutral and test wiring
Request the exact line, neutral and test-circuit diagram. Confirm pole configuration, supply terminals and enclosure integration.
W9 GROUPについて
W9 Group Support for JC3RS-EV Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-EV enquiry, contact W9 Group about configuration and matching product documents.

関連リソース
Request JC3RS-EV Residual Current Device Wiring and Response Data
Use technical support and related products to specify JC3RS-EV. Request a datasheet and wiring diagram matching the selected JC3RS-EV configuration.
購入者のよくある質問
JC3RS-EV RCD Waveform, Sensitivity and Wiring FAQs
Find answers about JC3RS-EV selection, configuration and ordering.
What does the JC3RS-EV product title identify?
W9 Group lists JC3RS-EV as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.
How do I confirm the JC3RS-EV residual-current waveform response?
Request the JC3RS-EV waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.
How should I specify JC3RS-EV sensitivity and rated current?
Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-EV order-code schedule.
Does JC3RS-EV include overload and short-circuit protection?
Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.
Which JC3RS-EV wiring diagram should I request?
Request the JC3RS-EV line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.
Can JC3RS-EV be specified for a charging circuit?
Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-EV and any separate protective devices meet that specific design.
What should I send for a JC3RS-EV quotation?
Send the complete JC3RS-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete JC3RS-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request JC3RS-EV Pricing and Technical Documents
W9 Group にご注文の全コード、回路の仕様、設置条件、必要な書類、数量、および配送先市場を伝えてください。そうすれば、選択された構成が特定できます。.