회로 보호 제품

홈제품회로 보호 제품RCCBJC3RS-EV Residual Current Device
  • JC3RS-EV 잔류 전류 장치 갤러리 이미지 1
  • JC3RS-EV Residual Current Device Gallery image 2
  • JC3RS-EV Residual Current Device Gallery image 3
  • JC3RS-EV Residual Current Device Gallery image 4
  • JC3RS-EV Residual Current Device Gallery image 5
  • JC3RS-EV Residual Current Device Gallery image 6
  • JC3RS-EV 잔류 전류 장치 갤러리 이미지 1
  • JC3RS-EV Residual Current Device Gallery image 2
  • JC3RS-EV Residual Current Device Gallery image 3
  • JC3RS-EV Residual Current Device Gallery image 4
  • JC3RS-EV Residual Current Device Gallery image 5
  • JC3RS-EV Residual Current Device Gallery image 6

JC3RS-EV 잔류 전류 장치

JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.

기술 데이터

JC3RS-EV Residual Current Device Product Information

JC3RS-EV appears in the W9 Group catalogue as a residual current device. Include the complete model when discussing the charging equipment, required residual-current response and supply configuration. Confirm the offered device functions on a JC3RS-EV-specific schedule.

The older summary and retained original table differ in sensitivity, current options and standards references. Confirm each operating threshold with its unit and the exact protection functions before installation.

표준 IEC61009-1, IEC62955
전기 기능 형태(지하 배수관 누설 감지된 파형) EV(A+DC leakage current)
정격 전류(A) 40, 63
폴란드인 1P+N, 3P+N
정격 전압 Ue(V) 1P+N: 230/240 3P+N: 400/415
등급 감도 IΔn 0.03mA
DC tripping threshold IΔdc 6mA
절연 전압 Ui(V) 500
Rated residual making and breaking capacity IΔm 500(In=25A/40A), 630(In=63A)
정격 주파수 50Hz
최대 절단 용량 10KA
SCPD fuse 10000A
Break time under IΔn ≤0.1s
인덕션 전류 저항 전압(1.2/50) Uimp(V) 4,000
1분 동안 인덕턴스 주파수에서 발생한 전압 (KV) 2.5
오염 정도 2
기계적 특징 전기 수명 2,000
기계적 수명 4,000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
기온(일일 평균 ≤35℃) -5…+40
저장 온도(℃) -25…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2/18-3AWG
버스바용 터미널 사이즈 상단/하단 10mm2/18-8AWG
강력한 토크 2.5N*m/22인치-파운드
장착 DIN 레일 EN 60715(35mm)에 맞게
연결 상단 또는 하단에서 사용할 수 있습니다.

선정 가이드

Selecting JC3RS-EV residual current device for Your Installation

Use JC3RS-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Choose the waveform response

Specify the connected equipment and expected residual-current waveform. Confirm the exact response type and any delay suffix.

02

Coordinate sensitivity and rated current

Choose the required residual-current threshold separately from the current-carrying rating. Confirm both in the ordered version.

03

Coordinate upstream protection

Request the manufacturer’s backup overcurrent and short-circuit coordination requirements for the actual supply and prospective fault level.

04

Plan neutral and test wiring

Request the exact line, neutral and test-circuit diagram. Confirm pole configuration, supply terminals and enclosure integration.

Before specifying JC3RS-EV: Confirm AC and DC operating thresholds with units, protection identity, current options and matching wiring documentation.

W9 그룹 소개

W9 Group Support for JC3RS-EV Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-EV enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

Request JC3RS-EV Residual Current Device Wiring and Response Data

Use technical support and related products to specify JC3RS-EV. Request a datasheet and wiring diagram matching the selected JC3RS-EV configuration.

구매자 FAQ

JC3RS-EV RCD Waveform, Sensitivity and Wiring FAQs

Find answers about JC3RS-EV selection, configuration and ordering.

What does the JC3RS-EV product title identify?

W9 Group lists JC3RS-EV as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.

How do I confirm the JC3RS-EV residual-current waveform response?

Request the JC3RS-EV waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.

How should I specify JC3RS-EV sensitivity and rated current?

Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-EV order-code schedule.

Does JC3RS-EV include overload and short-circuit protection?

Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.

Which JC3RS-EV wiring diagram should I request?

Request the JC3RS-EV line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.

Can JC3RS-EV be specified for a charging circuit?

Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-EV and any separate protective devices meet that specific design.

What should I send for a JC3RS-EV quotation?

Send the complete JC3RS-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3RS-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3RS-EV Pricing and Technical Documents

W9 Group에 주문번호, 회로 사용 목적, 설치 조건 및 필요한 서류, 수량 및 판매처를 알려주시면 선택된 구성이 확인될 수 있습니다.

W9 그룹에 문의하기