Dispositivo de corriente residual JC3RS-B
DATOS TÉCNICOS
JC3RS-B Residual Current Device Product Information
JC3RS-B is listed by W9 Group as a residual current device. Select it by the required residual-current waveform response, sensitivity, load current and pole arrangement. Ask W9 Group for the matching JC3RS-B operating and connection documents.
The model suffix and older Type B description are not matched by the Type AC/A variants in the retained original table. Confirm the waveform type for the quoted JC3RS-B; do not infer smooth-DC detection from the suffix.
| Estándar | IEC61008-1, EN61008-1 | |
| Características electrónicas | Corriente nominal en A (A) | 25, 40, 50, 63, 80, 100 |
| Tipo | Electromagnético | |
| Tipo (forma de onda de la fuga detectada) | Los modelos AC, A, AC-G, A-G, AC-S y A-S están disponibles. | |
| Polacos | 1P+N, 3P+N | |
| Tensión nominal Ue (V) | 1P+N: 230/240 3P+N: 400/415 | |
| Sensibilidad nominal IΔn | Están disponibles los modelos de 30 mA, 100 mA y 300 mA. | |
| Tensión de aislamiento Ui (V) | 500 | |
| Capacidad residual de formación y ruptura nominal IΔm | 500(In=25/40A), 630(In=63A), 1000(In=80/100A) | |
| Frecuencia nominal | 50/60Hz | |
| Capacidad de ruptura nominal | 6KA, 10KA | |
| Tensión de resistencia a la impulsión nominal (1,2/50) Uimp (V) | 6,000 | |
| Voltaje de prueba dieléctrica a la frecuencia indicada durante 1 minuto (KV) | 2.5 | |
| Nivel de contaminación | 2 | |
| Características mecánicas | Vida eléctrica | 2,000 |
| Vida mecánica | 4,000 | |
| Indicador de posición de contacto | Sí | |
| Nivel de protección | IP20 | |
| Temperatura de referencia para el ajuste del elemento térmico (℃) | 30 | |
| Temperatura ambiente (con promedio diario ≤35℃) | -5…+40 | |
| Temperatura de almacenamiento (℃) | -25…+70 | |
| Instalación | Tipo de conexión de terminal | Cable/tablero tipo U/tablero tipo pin |
| Dimensiones del terminal superior/inferior para el cable | 25 mm2/18-3 AWG | |
| Dimensiones terminales superiores/inferiores para la barra de bus | 10 mm2/18-8 AWG | |
| Torque de ajuste | 2,5 N*m/22 In-lbs | |
| Instalación | En el soporte de pared según la norma DIN EN 60715 (35 mm) | |
| Conexión | Están disponibles desde arriba o desde abajo |
Guía de selección
Selecting JC3RS-B residual current device for Your Installation
Use JC3RS-B as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
Elige la respuesta de la forma de onda
Especificar el equipo conectado y la forma de onda de la corriente residual esperada. Confirmar el tipo exacto de respuesta y cualquier sufijo de demora.
Sensibilidad de la coordinación y corriente nominal
El umbral de corriente residual requerido debe seleccionarse por separado de la clasificación de la corriente que transporta. Ambos valores deben confirmarse en la versión ordenada.
Coordinar la protección en el tramo aguas arriba
Solicite a la empresa fabricante los requisitos de coordinación de sobrecorriente y cortocircuito para el suministro actual y el nivel de fallo potencial.
Plan neutral y prueba de la instalación eléctrica
Solicite el diagrama exacto de la línea, el diagrama neutro y el diagrama de circuito de prueba. Confirme la configuración de los polos, los terminales de alimentación y la integración del enchufe.
QUÉ ES W9 GROUP
W9 Group Support for JC3RS-B Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-B enquiry, contact W9 Group about configuration and matching product documents.

RECURSOS RELACIONADOS
Request JC3RS-B Residual Current Device Wiring and Response Data
Use technical support and related products to specify JC3RS-B. Request a datasheet and wiring diagram matching the selected JC3RS-B configuration.
PRODUCTO RELACIONADOJC3RS RCDCompare función y configuración; solicite calificaciones separadas para cada modelo
DOCUMENTOSCentro de descarga de W9 GroupRequest the current document for your quoted JC3RS-B variant
Preguntas frecuentes del comprador
JC3RS-B RCD Waveform, Sensitivity and Wiring FAQs
Find answers about JC3RS-B selection, configuration and ordering.
What does the JC3RS-B product title identify?
W9 Group lists JC3RS-B as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.
How do I confirm the JC3RS-B residual-current waveform response?
Request the JC3RS-B waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.
How should I specify JC3RS-B sensitivity and rated current?
Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-B order-code schedule.
Does JC3RS-B include overload and short-circuit protection?
Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.
Which JC3RS-B wiring diagram should I request?
Request the JC3RS-B line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.
Can JC3RS-B be specified for a charging circuit?
Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-B and any separate protective devices meet that specific design.
What should I send for a JC3RS-B quotation?
Send the complete JC3RS-B designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete JC3RS-B designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request JC3RS-B Pricing and Technical Documents
Informe a W9 Group del código completo de su pedido, la función del circuito, las condiciones de instalación y los documentos requeridos, la cantidad y el mercado de destino para que pueda identificarse la configuración seleccionada.