技術データ
JC3RS-B Residual Current Device Product Information
JC3RS-B is listed by W9 Group as a residual current device. Select it by the required residual-current waveform response, sensitivity, load current and pole arrangement. Ask W9 Group for the matching JC3RS-B operating and connection documents.
The model suffix and older Type B description are not matched by the Type AC/A variants in the retained original table. Confirm the waveform type for the quoted JC3RS-B; do not infer smooth-DC detection from the suffix.
| スタンダード | IEC61008-1、EN61008-1 | |
| 電子機能 | 定格電流(A) | 25, 40, 50, 63, 80, 100 |
| タイプ | 電磁 | |
| タイプ(検出された漏れの波形) | AC、A、AC-G、A-G AC-S および A-S が利用可能です。 | |
| ポーランド人 | 1P+N、3P+N | |
| 定格電圧 Ue(V) | 1P+N: 230/240 3P+N: 400/415 | |
| 評価感度 IΔn | 30mA、100mA、300mA が用意されています。 | |
| 絶縁電圧 Ui(V) | 500 | |
| 定格残留形成および破壊能力 IΔm | 500(In=25/40A), 630(In=63A), 1000(In=80/100A) | |
| 定格周波数 | 50/60Hz | |
| 定格断面積 | 6KA、10KA | |
| 定格インパルス耐圧(1.2/50)Uimp(V) | 6,000 | |
| インダクタンス試験電圧(1分間、KV) | 2.5 | |
| 汚染度 | 2 | |
| 機械的特徴 | 電気寿命 | 2,000 |
| 機械的寿命 | 4,000 | |
| 接触位置インジケーター | はい | |
| 保護レベル | IP20 | |
| サーマルエレメントの設定時の基準温度(℃) | 30 | |
| 周囲温度(1日の平均が35℃以下) | -5…+40 | |
| 保管温度(℃) | -25…+70 | |
| インストール | ターミナル接続タイプ | ケーブル/U型バスバー/ピン型バスバー |
| ケーブル用の端末サイズの上部/下部 | 25mm2/18-3AWG | |
| バスバー用端子サイズの上部/下部 | 10mm2/18-8AWG | |
| 締めトルク | 2.5N*m/22インチ-lbs | |
| 取り付け | DINレール用 EN 60715(35mm) | |
| 接続 | 上部または下部から利用可能です |
選定ガイド
Selecting JC3RS-B residual current device for Your Installation
Use JC3RS-B as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.
波形応答を選択する
接続された機器と予想される残留電流波形を指定します。正確な応答タイプと遅延サフィックスを確認します。.
座標感度と定格電流
必要な残留電流閾値を電流伝達定格から別に選択してください。注文したバージョンで両方を確認してください。.
上流への保護を調整する
実際の供給および将来の障害レベルに対するメーカーのバックアップ過電流および短絡の調整要件を要求してください。.
計画を中立化し、配線をテストする
正確なライン図、中性回路図、テスト回路図をご依頼ください。ポール構成、電源端子、筐体一体化を確認いたします。.
W9 GROUPについて
W9 Group Support for JC3RS-B Product Enquiries
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-B enquiry, contact W9 Group about configuration and matching product documents.

関連リソース
Request JC3RS-B Residual Current Device Wiring and Response Data
Use technical support and related products to specify JC3RS-B. Request a datasheet and wiring diagram matching the selected JC3RS-B configuration.
購入者のよくある質問
JC3RS-B RCD Waveform, Sensitivity and Wiring FAQs
Find answers about JC3RS-B selection, configuration and ordering.
What does the JC3RS-B product title identify?
W9 Group lists JC3RS-B as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.
How do I confirm the JC3RS-B residual-current waveform response?
Request the JC3RS-B waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.
How should I specify JC3RS-B sensitivity and rated current?
Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-B order-code schedule.
Does JC3RS-B include overload and short-circuit protection?
Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.
Which JC3RS-B wiring diagram should I request?
Request the JC3RS-B line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.
Can JC3RS-B be specified for a charging circuit?
Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-B and any separate protective devices meet that specific design.
What should I send for a JC3RS-B quotation?
Send the complete JC3RS-B designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.
Send W9 Group the complete JC3RS-B designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.
Request JC3RS-B Pricing and Technical Documents
W9 Group にご注文の全コード、回路の仕様、設置条件、必要な書類、数量、および配送先市場を伝えてください。そうすれば、選択された構成が特定できます。.