サーキット保護製品

  • JC3RS-B残留電流検出器の画像ギャラリー 1
  • JC3RS-B Residual Current Device Gallery image 2
  • JC3RS-B Residual Current Device Gallery image 3
  • JC3RS-B Residual Current Device Gallery image 4
  • JC3RS-B Residual Current Device Gallery image 5
  • JC3RS-B Residual Current Device Gallery image 6
  • JC3RS-B残留電流検出器の画像ギャラリー 1
  • JC3RS-B Residual Current Device Gallery image 2
  • JC3RS-B Residual Current Device Gallery image 3
  • JC3RS-B Residual Current Device Gallery image 4
  • JC3RS-B Residual Current Device Gallery image 5
  • JC3RS-B Residual Current Device Gallery image 6

JC3RS-B残留電流検出器

JC3RS-B is listed by W9 Group as a residual current device. Select it by the required residual-current waveform response, sensitivity, load current and pole arrangement. Ask W9 Group for the matching JC3RS-B operating and connection documents.

技術データ

JC3RS-B Residual Current Device Product Information

JC3RS-B is listed by W9 Group as a residual current device. Select it by the required residual-current waveform response, sensitivity, load current and pole arrangement. Ask W9 Group for the matching JC3RS-B operating and connection documents.

The model suffix and older Type B description are not matched by the Type AC/A variants in the retained original table. Confirm the waveform type for the quoted JC3RS-B; do not infer smooth-DC detection from the suffix.

スタンダード IEC61008-1、EN61008-1
電子機能 定格電流(A) 25, 40, 50, 63, 80, 100
タイプ 電磁
タイプ(検出された漏れの波形) AC、A、AC-G、A-G AC-S および A-S が利用可能です。
ポーランド人 1P+N、3P+N
定格電圧 Ue(V) 1P+N: 230/240  3P+N: 400/415
評価感度 IΔn 30mA、100mA、300mA が用意されています。
絶縁電圧 Ui(V) 500
定格残留形成および破壊能力 IΔm 500(In=25/40A), 630(In=63A), 1000(In=80/100A)
定格周波数 50/60Hz
定格断面積 6KA、10KA
定格インパルス耐圧(1.2/50)Uimp(V) 6,000
インダクタンス試験電圧(1分間、KV) 2.5
汚染度 2
機械的特徴 電気寿命 2,000
機械的寿命 4,000
接触位置インジケーター はい
保護レベル IP20
サーマルエレメントの設定時の基準温度(℃) 30
周囲温度(1日の平均が35℃以下) -5…+40
保管温度(℃) -25…+70
インストール ターミナル接続タイプ ケーブル/U型バスバー/ピン型バスバー
ケーブル用の端末サイズの上部/下部 25mm2/18-3AWG
バスバー用端子サイズの上部/下部 10mm2/18-8AWG
締めトルク 2.5N*m/22インチ-lbs
取り付け DINレール用 EN 60715(35mm)
接続 上部または下部から利用可能です

選定ガイド

Selecting JC3RS-B residual current device for Your Installation

Use JC3RS-B as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

波形応答を選択する

接続された機器と予想される残留電流波形を指定します。正確な応答タイプと遅延サフィックスを確認します。.

02

座標感度と定格電流

必要な残留電流閾値を電流伝達定格から別に選択してください。注文したバージョンで両方を確認してください。.

03

上流への保護を調整する

実際の供給および将来の障害レベルに対するメーカーのバックアップ過電流および短絡の調整要件を要求してください。.

04

計画を中立化し、配線をテストする

正確なライン図、中性回路図、テスト回路図をご依頼ください。ポール構成、電源端子、筐体一体化を確認いたします。.

Before specifying JC3RS-B: Confirm the matching Type B rating schedule, waveform response, sensitivity and pole diagram for the exact offered unit.

W9 GROUPについて

W9 Group Support for JC3RS-B Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RS-B enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

Request JC3RS-B Residual Current Device Wiring and Response Data

Use technical support and related products to specify JC3RS-B. Request a datasheet and wiring diagram matching the selected JC3RS-B configuration.

購入者のよくある質問

JC3RS-B RCD Waveform, Sensitivity and Wiring FAQs

Find answers about JC3RS-B selection, configuration and ordering.

What does the JC3RS-B product title identify?

W9 Group lists JC3RS-B as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.

How do I confirm the JC3RS-B residual-current waveform response?

Request the JC3RS-B waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.

How should I specify JC3RS-B sensitivity and rated current?

Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RS-B order-code schedule.

Does JC3RS-B include overload and short-circuit protection?

Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.

Which JC3RS-B wiring diagram should I request?

Request the JC3RS-B line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.

Can JC3RS-B be specified for a charging circuit?

Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RS-B and any separate protective devices meet that specific design.

What should I send for a JC3RS-B quotation?

Send the complete JC3RS-B designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3RS-B designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3RS-B Pricing and Technical Documents

W9 Group にご注文の全コード、回路の仕様、設置条件、必要な書類、数量、および配送先市場を伝えてください。そうすれば、選択された構成が特定できます。.

W9グループへのお問い合わせ