MCCB circuit breaker Residual Current JC3RH-B Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

MCCB circuit breaker Residual Current JC3RH-B Type B detail image 1

機能

● Electromagnetic Type

● Earth leakage protection

● Breaking capacity 6kA,10kA

● Rated current up to 100A

● Detect smooth DC residual currents

● Tripping sensitivity: 30mA,100mA,300mA

● Connection from top or bottom

● Complies with IEC 61008-1 & IEC62423

申請

JC3RH-BS Type B RCCBs are suitable for nonlinear circuits that are able to generate leakages with high direct current (higher than 6 mA) and/or high frequency components, for example singlephase or poly-phase rectifiers, rectifiers with active correction of the power factor, continuous voltage generator with no separation from AC networks and inverters at variable frequency

B Type

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

MCCB circuit breaker Residual Current JC3RH-B Type B detail image 2

MCCB circuit breaker Residual Current JC3RH-B Type B detail image 3

Overall, the JCSD1-125 is a must-have accessory for anyone looking to increase the safety and efficiency of their electrical installations. Its intuitive design, rugged construction and compliance with industry standards make it an excellent solution for MCB and RCBO monitoring. With the JCSD1-125, users can control their circuits with confidence knowing they have a reliable and effective tool.

スタンダード IEC62423 & IEC61008-1
Electrical
features
Type (wave form of the earth leakage sensed) B
定格電流 In 25A, 40A, 63A, 80A, 100A
ポーランド人 1P+N, 3P+N
Rated voltage Ue 1P+N:230V/240V~; 3P+N:400V/415V~;
Rated sensitivity I∆n 0.03A, 0.1A, 0.3A
絶縁電圧 Ui 500V
Rated residual making and breaking capacity I∆m 500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A
Short-circuit current Inc=I∆c 6kA,10kA
SCPD fuse 10000A
break time under I∆n ≤0.1 S
定格周波数 50Hz
Rated impulse withstand voltage(1.2/50) Uimp 4,000V
Dielectric test voltage at ind. Freq. for 1 min 2.5 kV
汚染度 2
Mechanical
features
電気寿命 2, 000
機械的寿命 10,000
Fault current indicator はい
保護レベル IP20
Ambient temperature (with daily average≤35°C) -25°C…+40°C
Storage temperation -25°C…+70°C
インストール ターミナル接続タイプ ケーブル/U型バスバー/ピン型バスバー
ケーブル用の端末サイズの上部/下部 25/35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
締めトルク 2.5 N·m
22 In-Ibs.
取り付け On DIN rail EN 60715 (35mm)
接続 From top and bottom

MCCB circuit breaker Residual Current JC3RH-B Type B detail image 4