MCCB circuit breaker Residual Current JC3RH-B Type B

Características
● Electromagnetic Type
● Earth leakage protection
● Breaking capacity 6kA,10kA
● Rated current up to 100A
● Detect smooth DC residual currents
● Tripping sensitivity: 30mA,100mA,300mA
● Connection from top or bottom
● Complies with IEC 61008-1 & IEC62423
Solicitud
JC3RH-BS Type B RCCBs are suitable for nonlinear circuits that are able to generate leakages with high direct current (higher than 6 mA) and/or high frequency components, for example singlephase or poly-phase rectifiers, rectifiers with active correction of the power factor, continuous voltage generator with no separation from AC networks and inverters at variable frequency
B Type
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.


Overall, the JCSD1-125 is a must-have accessory for anyone looking to increase the safety and efficiency of their electrical installations. Its intuitive design, rugged construction and compliance with industry standards make it an excellent solution for MCB and RCBO monitoring. With the JCSD1-125, users can control their circuits with confidence knowing they have a reliable and effective tool.
| Estándar | IEC62423 & IEC61008-1 | |
|
Electrical features |
Type (wave form of the earth leakage sensed) | B |
| Corriente nominal | 25A, 40A, 63A, 80A, 100A | |
| Polacos | 1P+N, 3P+N | |
| Rated voltage Ue | 1P+N:230V/240V~; 3P+N:400V/415V~; | |
| Rated sensitivity I∆n | 0.03A, 0.1A, 0.3A | |
| Tensión de aislamiento Ui | 500V | |
| Rated residual making and breaking capacity I∆m | 500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A | |
| Short-circuit current Inc=I∆c | 6kA,10kA | |
| SCPD fuse | 10000A | |
| break time under I∆n | ≤0.1 S | |
| Frecuencia nominal | 50Hz | |
| Rated impulse withstand voltage(1.2/50) Uimp | 4,000V | |
| Dielectric test voltage at ind. Freq. for 1 min | 2.5 kV | |
| Nivel de contaminación | 2 | |
|
Mechanical features |
Vida eléctrica | 2, 000 |
| Vida mecánica | 10,000 | |
| Fault current indicator | Sí | |
| Nivel de protección | IP20 | |
| Ambient temperature (with daily average≤35°C) | -25°C…+40°C | |
| Storage temperation | -25°C…+70°C | |
| Instalación | Tipo de conexión de terminal | Cable/tablero tipo U/tablero tipo pin |
| Dimensiones del terminal superior/inferior para el cable | 25/35 mm² | |
| 18-3/18-2 AWG | ||
| Terminal size top/bottom for busbar | 10/16 mm² | |
| 18-8/18-5 AWG | ||
| Torque de ajuste | 2.5 N·m | |
| 22 In-Ibs. | ||
| Instalación | On DIN rail EN 60715 (35mm) | |
| Conexión | From top and bottom |