JC3RH-EV 잔류 전류 장치

W9 Group lists JC3RH-EV as a residual current device. For enquiries involving an EV charging circuit, provide the charger requirements and supply arrangement, then confirm the exact detection functions, sensitivity and current rating for the offered JC3RH-EV.

기술 데이터

JC3RH-EV Residual Current Device Product Information

W9 Group lists JC3RH-EV as a residual current device. For enquiries involving an EV charging circuit, provide the charger requirements and supply arrangement, then confirm the exact detection functions, sensitivity and current rating for the offered JC3RH-EV.

The older summary and retained original table differ in sensitivity, current options and standards references. Confirm each operating threshold with its unit and the exact protection functions before installation.

표준 IEC61009-1, IEC62955
전기 기능 형태(지하 배수관 누설 감지된 파형) EV(A+DC leakage current)
정격 전류(A) 40, 63
폴란드인 1P+N, 3P+N
정격 전압 Ue(V) 1P+N: 230/240 3P+N: 400/415
등급 감도 IΔn 0.03mA
DC tripping threshold IΔdc 6mA
절연 전압 Ui(V) 500
등급 잔류 제작 및 파괴 용량 IΔm 500(In=25A/40A), 630(In=63A)
정격 주파수 50Hz
최대 절단 용량 10KA
SCPD fuse 10000A
Break time under IΔn ≤0.1s
인덕션 전류 저항 전압(1.2/50) Uimp(V) 4,000
1분 동안 인덕턴스 주파수에서 발생한 전압 (KV) 2.5
오염 정도 2
기계적 특징 전기 수명 2,000
기계적 수명 4,000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
기온(일일 평균 ≤35℃) -5…+40
저장 온도(℃) -25…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2/18-3AWG
버스바용 터미널 사이즈 상단/하단 10mm2/18-8AWG
강력한 토크 2.5N*m/22인치-파운드
장착 DIN 레일 EN 60715(35mm)에 맞게
연결 상단 또는 하단에서 사용할 수 있습니다.

선정 가이드

Selecting JC3RH-EV residual current device for Your Installation

Use JC3RH-EV as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

파형 응답 선택하기

연결된 장비와 예상 잔류 전류 파형을 지정합니다. 정확한 응답 유형과 지연 부호를 확인합니다.

02

위상 감도 및 정격 전류

필요한 잔류 전류 임계값을 전류 전달 용량과 별도로 선택하십시오. 주문된 버전에서 두 가지 모두 확인하십시오.

03

상류 보호 조치 조정

제조사의 백업 전원 과전류 및 단락 시 동기화 요구 사항을 확인하여 실제 공급 및 잠재적인 장애 수준을 파악하십시오.

04

중립 계획 및 테스트 배선

정확한 선도, 중립도 및 테스트 회로도 요청. 폴드 구성, 공급 단자 및 케이스 통합 확인.

Before specifying JC3RH-EV: Confirm AC and DC operating thresholds with units, protection identity, current options and matching wiring documentation.

W9 그룹 소개

W9 Group Support for JC3RH-EV Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH-EV enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

Request JC3RH-EV Residual Current Device Wiring and Response Data

Use technical support and related products to specify JC3RH-EV. Request a datasheet and wiring diagram matching the selected JC3RH-EV configuration.

구매자 FAQ

JC3RH-EV RCD Waveform, Sensitivity and Wiring FAQs

Find answers about JC3RH-EV selection, configuration and ordering.

What does the JC3RH-EV product title identify?

W9 Group lists JC3RH-EV as a residual current device. Confirm the complete order code and offered protection functions on the matching device schedule.

How do I confirm the JC3RH-EV residual-current waveform response?

Request the JC3RH-EV waveform-response specification for the quoted unit. Confirm the required AC, pulsating-DC or smooth-DC coverage with the equipment design; the model suffix alone is insufficient.

How should I specify JC3RH-EV sensitivity and rated current?

Provide the required residual-current threshold with its unit and the load current as separate selections. Confirm both values on one JC3RH-EV order-code schedule.

Does JC3RH-EV include overload and short-circuit protection?

Confirm the exact device functions and any required upstream breaker or fuse. A residual-current device title alone does not establish combined overcurrent protection.

Which JC3RH-EV wiring diagram should I request?

Request the JC3RH-EV line, neutral, supply and test-circuit diagram for the offered poles. Confirm terminal assignments and mounting dimensions before arranging the board.

Can JC3RH-EV be specified for a charging circuit?

Provide the charger instructions, supply arrangement and required detection functions. Confirm whether the quoted JC3RH-EV and any separate protective devices meet that specific design.

What should I send for a JC3RH-EV quotation?

Send the complete JC3RH-EV designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JC3RH-EV designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JC3RH-EV Pricing and Technical Documents

W9 Group에 주문번호, 회로 사용 목적, 설치 조건 및 필요한 서류, 수량 및 판매처를 알려주시면 선택된 구성이 확인될 수 있습니다.

W9 그룹에 문의하기