JC3RH-BS Type B RCCB

The JC3RH-BS Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code. Request the selected configuration and matching technical documents from W9 Group.

기술 데이터

JC3RH-BS Type B RCCB for AC, Pulsating DC and Smooth DC Residual Currents

The JC3RH-BS Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code.

표준 IEC62423 & IEC61008-1
Electrical
features
Type (wave form of the earth leakage sensed) B
정격 전류 In 25A, 40A, 63A, 80A, 100A
폴란드인 1P+N, 3P+N
Rated voltage Ue 1P+N:230V/240V~; 3P+N:400V/415V~;
Rated sensitivity I∆n 0.03A, 0.1A, 0.3A
절연 전압 Ui 500V
Rated residual making and breaking capacity I∆m 500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A
Short-circuit current Inc=I∆c 6kA,10kA
SCPD fuse 10000A
break time under I∆n ≤0.1 S
정격 주파수 50Hz
Rated impulse withstand voltage(1.2/50) Uimp 4,000V
Dielectric test voltage at ind. Freq. for 1 min 2.5 kV
오염 정도 2
Mechanical
features
전기 수명 2, 000
기계적 수명 10,000
Fault current indicator 네
보호 수준 IP20
Ambient temperature (with daily average≤35°C) -25°C…+40°C
Storage temperation -25°C…+70°C
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25/35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
강력한 토크 2.5 N·m
22 In-Ibs.
장착 On DIN rail EN 60715 (35mm)
연결 From top and bottom

선정 가이드

How to Select a JC3RH-BS Type B RCCB by Poles, Current and Sensitivity

Specify the complete order code, load type, poles, supply voltage, current, sensitivity and backup device when requesting a JC3RH-BS quotation from W9 Group.

01

Identify the leakage waveform

Check the load manufacturer requirements for smooth-DC and frequency-dependent residual currents. Confirm the Type B response envelope for the exact device.

02

Match poles and neutral wiring

Specify 1P+N or 3P+N and the actual supply voltage. Request the neutral-terminal, supply and load connection diagram.

03

Choose current and sensitivity

Select rated current and residual-current sensitivity separately. Confirm the protection objective and upstream/downstream trip-time coordination.

04

Check backup and application rules

Request the permitted backup protective device and conditional short-circuit data. For inverter or charging circuits, include the equipment protection specification.

Before specifying JC3RH-BS: Confirm the exact Type B response data, neutral wiring, sensitivity, delay class and upstream protection. A standards reference is not an independently verified certificate.

W9 그룹 소개

W9 Group JC3RH-BS Type B Residual Current Circuit Breaker Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH-BS enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

JC3RH-BS Type B RCCB Wiring, Trip-Time and Backup-Protection Documents

Use technical support and related products to specify JC3RH-BS. Request a datasheet and wiring diagram matching the selected JC3RH-BS configuration.

구매자 FAQ

JC3RH-BS Type B RCCB FAQs: Smooth DC, Inverter Loads and Selectivity

Find answers about JC3RH-BS selection, configuration and ordering.

What does Type B mean on the JC3RH-BS RCCB?

Here Type B describes the residual-current waveform response, including smooth DC in the supplier description. It is different from the B overcurrent trip curve used to describe an MCB.

Which current and sensitivity options are listed?

The target table lists 25 A, 40 A, 63 A, 80 A and 100 A, with residual-current sensitivity choices of 0.03 A, 0.1 A and 0.3 A. Confirm the selected combination.

Which supply and pole configurations are available?

The table lists 1P+N at 230/240 V AC and 3P+N at 400/415 V AC, with a rated frequency of 50 Hz. Confirm the offered configuration and neutral connection diagram.

Can I use it with an inverter, rectifier or charging circuit?

The supplier discusses nonlinear loads and smooth-DC leakage. Confirm the equipment maker requirements, residual-current spectrum, local installation rules and exact-model response data; this is not a universal application approval.

Does the RCCB include overload and short-circuit protection?

The target identifies an RCCB and cites residual-current standards. Confirm a separate overcurrent protective device and the specified conditional short-circuit arrangement; do not interpret conditional capacity as integrated overcurrent protection.

Does the BS suffix guarantee selective or time-delayed tripping?

A suffix alone is insufficient. The available shared schedule does not establish a distinct selective curve for every model. Confirm the exact delay class and trip-time data before coordinating devices.

What is needed for a JC3RH-BS quotation?

필수 구성, 수량, 대상 시장, 문서 요구 사항을 보내주세요. 선택한 구성에 대한 가격, 최소 주문 수량, 샘플 및 리드 타임을 W9 Group에 확인해 주세요.

제품 문의

Request a JC3RH-BS Type B RCCB Quotation

Tell W9 Group your complete order code, load type, poles, supply voltage, current, sensitivity and backup device, quantity and destination market so the selected configuration can be identified.