JC3RH-BS نوع B RCCB

The JC3RH-BS Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code. Request the selected configuration and matching technical documents from W9 Group.

اطلاعات فنی

JC3RH-BS Type B RCCB for AC, Pulsating DC and Smooth DC Residual Currents

The JC3RH-BS Type B RCCB is listed by W9 Group for residual-current protection where the load can produce sinusoidal AC, pulsating DC or smooth DC leakage components. The target table offers 1P+N and 3P+N configurations. Select the current, sensitivity and backup protective device using documentation matching the complete order code.

استاندارد IEC62423 & IEC61008-1
الکترونیک
features
نوع (فرم موج عبور جریان زمین را حس کرده‌ایم) B
مقدار جریان ورودی 25A, 40A, 63A, 80A, 100A
پوشندگان لهستانی 1P+N, 3P+N
Rated voltage Ue 1P+N:230V/240V~; 3P+N:400V/415V~;
حساسیت نرخ‌دهی‌شده I∆n 0.03A, 0.1A, 0.3A
تنظیم ولتاژ عایق Ui 500V
Rated residual making and breaking capacity I∆m 500 (In=25A/40A), 630 (In=63A), 1000(In=80A/100A
Short-circuit current Inc=I∆c 6kA,10kA
SCPD fuse 10000A
break time under I∆n ≤0.1 S
فراوانی رتبهبندی شده 50Hz
Rated impulse withstand voltage(1.2/50) Uimp 4,000V
Dielectric test voltage at ind. Freq. for 1 min 2.5 kV
سطح آلودگی 2
ماشینی
features
زندگی الکتریکی 2, 000
زمان کارکرد مکانیکی 10,000
Fault current indicator بله
سطح حفاظت IP20
دمای محیط (با میانگین روزانه ≤35 درجه سانتیگراد) -25°C…+40°C
Storage temperation -25°C…+70°C
ارائه نصب نوع اتصال ترمینال کابل/پیوستهای U-type/پیوستهای Pin-type
ابعاد بالایی/پایینی ترمینال برای کابل 25/35 mm²
18-3/18-2 AWG
اندازهٔ پایانهٔ بالایی/پایینی برای تابلو 10/16 mm²
18-8/18-5 AWG
تنگ کردن گشتاور ۲٫۵ نیوتن بر متر
22 In-Ibs.
قرارگیری On DIN rail EN 60715 (35mm)
اتصال From top and bottom

راهنمای انتخاب

How to Select a JC3RH-BS Type B RCCB by Poles, Current and Sensitivity

Specify the complete order code, load type, poles, supply voltage, current, sensitivity and backup device when requesting a JC3RH-BS quotation from W9 Group.

01

Identify the leakage waveform

Check the load manufacturer requirements for smooth-DC and frequency-dependent residual currents. Confirm the Type B response envelope for the exact device.

02

Match poles and neutral wiring

Specify 1P+N or 3P+N and the actual supply voltage. Request the neutral-terminal, supply and load connection diagram.

03

Choose current and sensitivity

Select rated current and residual-current sensitivity separately. Confirm the protection objective and upstream/downstream trip-time coordination.

04

Check backup and application rules

Request the permitted backup protective device and conditional short-circuit data. For inverter or charging circuits, include the equipment protection specification.

Before specifying JC3RH-BS: Confirm the exact Type B response data, neutral wiring, sensitivity, delay class and upstream protection. A standards reference is not an independently verified certificate.

درباره W9 Group

W9 Group JC3RH-BS Type B Residual Current Circuit Breaker Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JC3RH-BS enquiry, contact W9 Group about configuration and matching product documents.

دامنه محصولات حفاظتی مدار W9 Group برای OEM و ODM
رنج حفاظت مدار W9 — تصویر کلیه دسته‌ها.

منابع مرتبط

JC3RH-BS Type B RCCB Wiring, Trip-Time and Backup-Protection Documents

Use technical support and related products to specify JC3RH-BS. Request a datasheet and wiring diagram matching the selected JC3RH-BS configuration.

سوالات متداول خریداران

JC3RH-BS Type B RCCB FAQs: Smooth DC, Inverter Loads and Selectivity

Find answers about JC3RH-BS selection, configuration and ordering.

What does Type B mean on the JC3RH-BS RCCB?

Here Type B describes the residual-current waveform response, including smooth DC in the supplier description. It is different from the B overcurrent trip curve used to describe an MCB.

Which current and sensitivity options are listed?

The target table lists 25 A, 40 A, 63 A, 80 A and 100 A, with residual-current sensitivity choices of 0.03 A, 0.1 A and 0.3 A. Confirm the selected combination.

Which supply and pole configurations are available?

The table lists 1P+N at 230/240 V AC and 3P+N at 400/415 V AC, with a rated frequency of 50 Hz. Confirm the offered configuration and neutral connection diagram.

Can I use it with an inverter, rectifier or charging circuit?

The supplier discusses nonlinear loads and smooth-DC leakage. Confirm the equipment maker requirements, residual-current spectrum, local installation rules and exact-model response data; this is not a universal application approval.

Does the RCCB include overload and short-circuit protection?

The target identifies an RCCB and cites residual-current standards. Confirm a separate overcurrent protective device and the specified conditional short-circuit arrangement; do not interpret conditional capacity as integrated overcurrent protection.

Does the BS suffix guarantee selective or time-delayed tripping?

A suffix alone is insufficient. The available shared schedule does not establish a distinct selective curve for every model. Confirm the exact delay class and trip-time data before coordinating devices.

What is needed for a JC3RH-BS quotation?

اطلاعات مورد نیاز را، تعداد، بازار مقصد و الزامات اسناد را ارسال کنید. از W9 Group درخواست کنید تا قیمت، حداقل مقدار سفارش، نمونه‌ها و زمان تحویل برای پیکربندی انتخاب شده را تأیید کند.

سؤال و جواب درباره محصول

Request a JC3RH-BS Type B RCCB Quotation

Tell W9 Group your complete order code, load type, poles, supply voltage, current, sensitivity and backup device, quantity and destination market so the selected configuration can be identified.