Продукты для защиты от перегрузок

  • Миниатюрный выключатель JCB1-125 6kA/10kA Галерея изображения 1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • Миниатюрный выключатель JCB1-125 6kA/10kA Галерея изображения 1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA

JCB1-125 Miniature Circuit Breaker

W9 Group lists the JCB1-125 miniature circuit breaker for overload and short-circuit protection. The catalog offers 63–125 A current options, single-pole through four-pole configurations and B, C or D trip curves for distribution circuits. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB1-125 63–125A Miniature Circuit Breaker Specifications

W9 Group lists the JCB1-125 miniature circuit breaker for overload and short-circuit protection. The catalog offers 63–125 A current options, single-pole through four-pole configurations and B, C or D trip curves for distribution circuits.

JCB1-125 product specifications
Product model JCB1-125
Protection function Overload and short circuit
Catalog current range 63–125 A
Pole options 1P, 2P, 3P, 4P
Trip curves B / C / D
Breaking-capacity options 6 kA / 10 kA; confirm the ordered version
Индикатор положения контакта Listed
Standard listed by supplier IEC 60898-1; request applicable documents
Module width 27 mm

ГИД ПО ОТБЕРЕЖЕ

Selecting a 1 Pole to 4 Pole MCB with B, C or D Curve

Specify the rated current, pole count, trip curve, supply voltage and required breaking capacity when you request a JCB1-125 quotation from W9 Group.

01

Choose the rated current

For JCB1-125, match the ordered current to the circuit design and conductor protection requirements; the catalog range is 63–125 A.

02

Choose the trip curve

Specify B, C or D and request the corresponding time-current curve to assess starting current and coordination.

03

Match pole count and fault duty

State the number of poles and supply voltage. Confirm that the selected breaking rating meets the prospective short-circuit current.

04

Check mounting and connections

Request the terminal, busbar and mounting drawing for the ordered version before finalizing the distribution board.

Before ordering JCB1-125: confirm rated current, pole count, trip curve, supply voltage and required breaking capacity, the matching datasheet and the installation drawing.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB1-125 Miniature Circuit Breaker Technical Document Requests

Use W9 Group technical support and the product directory to specify JCB1-125. Request the matching datasheet before ordering.

Часто задаваемые вопросы покупателей

MCB FAQs: 6kA or 10kA Variants and Current Options

Find answers about JCB1-125 selection, configuration and ordering.

What does JCB1-125 protect against?

The supplier lists overload and short-circuit protection. Confirm any separate residual-current protection required by the installation.

Which current options are listed?

W9 Group lists 63–125 A for this model range. Ask for the exact order code and available current steps.

How do I choose the trip curve?

The catalog offers B, C and D. Request the selected curve and check it against the load starting behavior and upstream protection.

What is needed for a JCB1-125 quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

What pole options are available for JCB1-125?

The catalog lists 1P, 2P, 3P and 4P configurations. Confirm the pole count, supply voltage and complete order code before ordering.

How should I specify the breaking capacity?

The source lists 6 kA and 10 kA versions for this model. Match the selected breaking capacity to the prospective short-circuit current and request the applicable datasheet.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB1-125 Miniature Circuit Breaker Quotation

Tell W9 Group your rated current, pole count, trip curve, supply voltage and required breaking capacity, quantity and destination market so the selected configuration can be identified.

Свяжитесь с W9 Group