회로 보호 제품

홈제품회로 보호 제품MCBJCB1-125 Miniature Circuit Breaker
  • 미니트랜스커 JCB1-125 6kA/10kA 갤러리 이미지 1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • 미니트랜스커 JCB1-125 6kA/10kA 갤러리 이미지 1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA

JCB1-125 소형 차단기

W9 Group lists JCB1-125 as a miniature circuit breaker. For distribution-board enquiries, specify the required current, poles and trip curve, then confirm the complete selection on the matching JCB1-125 datasheet.

기술 데이터

JCB1-125 Miniature Circuit Breaker Specifications

W9 Group lists JCB1-125 as a miniature circuit breaker. For distribution-board enquiries, specify the required current, poles and trip curve, then confirm the complete selection on the matching JCB1-125 datasheet.

The catalogue current range and retained original table differ. Confirm the ordered current with W9 Group before using this schedule for selection.

표준 IEC/EN 60898-1  IEC/EN 60947-2

전기 기능

정격 전류(A) 1, 2, 3, 4, 6, 10, 16,
20, 25, 32, 40, 50, 63,80
폴란드인 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
정격 전압 Ue(V) 230/400~240/415
절연 전압 Ui(V) 500
정격 주파수 50/60Hz
최대 절단 용량 10 kA
Energy limiting class 3
정격 임펄스 내전압(1.2/50) Uimp (V) 4000
Dielectric test voltage at ind. Freq. for 1 min (kV) 2
오염 정도 2
Power loss per pole Rated current (A)
1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80
열 자성 방출 특성 B, C, D 8-12In, 9.6-14.4In

기계적 특징

전기 수명 4, 000
기계적 수명 20, 000
접촉 위치 표시기 네
보호 수준 IP20
열체 열 설정 기준 온도(℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -35…+70
설치 터미널 연결 유형 케이블/U형 버스바/핀형 버스바
케이블의 상단/하단 터미널 사이즈 25mm2  / 18-4 AWG
버스바용 터미널 사이즈 상단/하단 10mm2  / 18-8 AWG
강력한 토크 2.5 N*m  /  22 In-Ibs.
장착 DIN 레일 EN 60715(35mm)에 고속 클립 장치를 사용하여 장착
연결 From top and bottom

Combination
with
accessories

보조 연락처 네
스촇 방출 네
전압 감소 시 네
알람 접촉 네

선정 가이드

Selecting JCB1-125 miniature circuit breaker for Your Installation

Use JCB1-125 as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Choose the rated current

For JCB1-125, specify the circuit design current and conductor protection requirements. Ask W9 Group to confirm the available current steps for the exact order code.

02

Choose the trip curve

Specify B, C or D and request the corresponding time-current curve to assess starting current and coordination.

03

Match pole count and fault duty

State the number of poles and supply voltage. Confirm that the selected breaking rating meets the prospective short-circuit current.

04

Check mounting and connections

Request the terminal, busbar and mounting drawing for the ordered version before finalizing the distribution board.

Before ordering JCB1-125: confirm rated current, pole count, trip curve, supply voltage and required breaking capacity, the matching datasheet and the installation drawing.

W9 그룹 소개

W9 Group Support for JCB1-125 Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB1-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 그룹 OEM 및 ODM 회로 보호 제품 범위
W9 그룹 회로 보호 범위 — 범주 그림.

관련 자료

Request JCB1-125 MCB Trip Curves and Installation Drawings

Use W9 Group technical support and the product directory to specify JCB1-125. Request the matching datasheet before ordering.

구매자 FAQ

JCB1-125 MCB Current, Trip-Curve and Installation FAQs

Find answers about JCB1-125 selection, configuration and ordering.

What does JCB1-125 protect against?

The supplier lists overload and short-circuit protection. Confirm any separate residual-current protection required by the installation.

Which current options are listed?

Ask W9 Group to confirm the available JCB1-125 current steps on a matching order-code datasheet before ordering.

How do I choose the trip curve?

The catalog offers B, C and D. Request the selected curve and check it against the load starting behavior and upstream protection.

What pole options are available for JCB1-125?

The catalog lists 1P, 2P, 3P and 4P configurations. Confirm the pole count, supply voltage and complete order code before ordering.

How should I specify the breaking capacity?

The source lists 6 kA and 10 kA versions for this model. Match the selected breaking capacity to the prospective short-circuit current and request the applicable datasheet.

Which JCB1-125 dimensions should I check before fitting the MCB?

Request the exact JCB1-125 outline, terminal and busbar drawing. Confirm the selected pole arrangement and available board space before installation.

What should I send for a JCB1-125 quotation?

Send the complete JCB1-125 designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JCB1-125 designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JCB1-125 Pricing and Technical Documents

Tell W9 Group your rated current, pole count, trip curve, supply voltage and required breaking capacity, quantity and destination market so the selected configuration can be identified.