サーキット保護製品

ホーム製品サーキット保護製品MCBJCB1-125 Miniature Circuit Breaker
  • ミニチュア遮断器 JCB1-125 6kA/10kA ギャラリー画像1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • ミニチュア遮断器 JCB1-125 6kA/10kA ギャラリー画像1
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 2
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 3
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 4
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 5
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 6
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 7
  • Miniature Circuit Breaker JCB1-125 6kA/10kA Gallery image 8
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA
  • JCB1-125 Miniature Circuit Breaker 6kA/10kA

JCB1-125 小型遮断器

W9 Group lists JCB1-125 as a miniature circuit breaker. For distribution-board enquiries, specify the required current, poles and trip curve, then confirm the complete selection on the matching JCB1-125 datasheet.

技術データ

JCB1-125 Miniature Circuit Breaker Specifications

W9 Group lists JCB1-125 as a miniature circuit breaker. For distribution-board enquiries, specify the required current, poles and trip curve, then confirm the complete selection on the matching JCB1-125 datasheet.

The catalogue current range and retained original table differ. Confirm the ordered current with W9 Group before using this schedule for selection.

スタンダード IEC/EN 60898-1  IEC/EN 60947-2

電気機能

定格電流(A) 1, 2, 3, 4, 6, 10, 16,
20, 25, 32, 40, 50, 63,80
ポーランド人 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
定格電圧 Ue(V) 230/400~240/415
絶縁電圧 Ui(V) 500
定格周波数 50/60Hz
定格断面積 10 kA
Energy limiting class 3
耐 impulse電圧(1.2/50)Uimp(V) 4000
Dielectric test voltage at ind. Freq. for 1 min (kV) 2
汚染度 2
Power loss per pole Rated current (A)
1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80
熱磁性放出特性 B, C, D 8-12In, 9.6-14.4In

機械的特徴

電気寿命 4, 000
機械的寿命 20, 000
接触位置インジケーター はい
保護レベル IP20
サーマルエレメントの設定時の基準温度(℃) 30
周囲温度(日平均値が35℃以下) -5…+40
保管温度(℃) -35…+70
インストール ターミナル接続タイプ ケーブル/U型バスバー/ピン型バスバー
ケーブル用の端末サイズの上部/下部 25mm2  / 18-4 AWG
バスバー用端子サイズの上部/下部 10mm2  / 18-8 AWG
締めトルク 2.5 N*m  /  22 In-Ibs.
取り付け DINレール用 EN 60715 (35mm) 用、高速クリップ装置による取り付け
接続 From top and bottom

Combination
with
accessories

補助連絡先 はい
シュントの放出 はい
電圧降下時の放電 はい
アラームコンタクト はい

選定ガイド

Selecting JCB1-125 miniature circuit breaker for Your Installation

Use JCB1-125 as the enquiry reference and confirm the selected configuration against your circuit, connection and installation requirements.

01

Choose the rated current

For JCB1-125, specify the circuit design current and conductor protection requirements. Ask W9 Group to confirm the available current steps for the exact order code.

02

Choose the trip curve

Specify B, C or D and request the corresponding time-current curve to assess starting current and coordination.

03

Match pole count and fault duty

State the number of poles and supply voltage. Confirm that the selected breaking rating meets the prospective short-circuit current.

04

Check mounting and connections

Request the terminal, busbar and mounting drawing for the ordered version before finalizing the distribution board.

Before ordering JCB1-125: confirm rated current, pole count, trip curve, supply voltage and required breaking capacity, the matching datasheet and the installation drawing.

W9 GROUPについて

W9 Group Support for JCB1-125 Product Enquiries

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB1-125 enquiry, contact W9 Group about configuration and matching product documents.

W9 GroupのOEMおよびODM向け回路保護製品の範囲
W9 グループのサーキット保護製品ラインナップ — カテゴリのイラスト。.

関連リソース

Request JCB1-125 MCB Trip Curves and Installation Drawings

Use W9 Group technical support and the product directory to specify JCB1-125. Request the matching datasheet before ordering.

購入者のよくある質問

JCB1-125 MCB Current, Trip-Curve and Installation FAQs

Find answers about JCB1-125 selection, configuration and ordering.

What does JCB1-125 protect against?

The supplier lists overload and short-circuit protection. Confirm any separate residual-current protection required by the installation.

Which current options are listed?

Ask W9 Group to confirm the available JCB1-125 current steps on a matching order-code datasheet before ordering.

How do I choose the trip curve?

The catalog offers B, C and D. Request the selected curve and check it against the load starting behavior and upstream protection.

What pole options are available for JCB1-125?

The catalog lists 1P, 2P, 3P and 4P configurations. Confirm the pole count, supply voltage and complete order code before ordering.

How should I specify the breaking capacity?

The source lists 6 kA and 10 kA versions for this model. Match the selected breaking capacity to the prospective short-circuit current and request the applicable datasheet.

Which JCB1-125 dimensions should I check before fitting the MCB?

Request the exact JCB1-125 outline, terminal and busbar drawing. Confirm the selected pole arrangement and available board space before installation.

What should I send for a JCB1-125 quotation?

Send the complete JCB1-125 designation, required configuration, quantity, destination market and documents needed. Ask W9 Group to confirm the offered item, price, minimum order quantity and delivery terms.

Send W9 Group the complete JCB1-125 designation, circuit or host-equipment requirements, quantity and destination market. Request the exact offered configuration and its matching technical documents.

Request JCB1-125 Pricing and Technical Documents

Tell W9 Group your rated current, pole count, trip curve, supply voltage and required breaking capacity, quantity and destination market so the selected configuration can be identified.

W9グループへのお問い合わせ