Продукты для защиты от перегрузок

  • Миниатюрный выключатель JCB3-40M 6kA 1P+N Галерея изображения 1
  • Miniature Circuit Breaker JCB3-40M 6kA 1P+N Gallery image 2
  • Miniature Circuit Breaker JCB3-40M 6kA 1P+N Gallery image 3
  • Миниатюрный выключатель JCB3-40M 6kA 1P+N Галерея изображения 1
  • Miniature Circuit Breaker JCB3-40M 6kA 1P+N Gallery image 2
  • Miniature Circuit Breaker JCB3-40M 6kA 1P+N Gallery image 3

JCB3-40M MCB

The JCB3-40M MCB is a miniature circuit breaker for overload and short-circuit protection. W9 Group lists 1–40 A and a 6 kA breaking rating, with 1P+N configurations. Its 18 mm single-module format is intended for compact distribution-board layouts. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB3-40M 6kA 1P+N MCB Specifications

The JCB3-40M MCB is a miniature circuit breaker for overload and short-circuit protection. W9 Group lists 1–40 A and a 6 kA breaking rating, with 1P+N configurations. Its 18 mm single-module format is intended for compact distribution-board layouts.

Стандартный IEC/EN 60898-1  IEC/EN 60947-2

Электрические характеристики

Максимальный ток в А (А) 1, 2, 3, 4, 6, 10, 16,
20, 25, 32, 40, 50, 63,80
Поляки 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
Номинальное напряжение Ue (V) 230/400~240/415
Изоляционное напряжение Ui (В) 500
Определенная частота 50/60 Гц
Максимальный пробойной прочность 10 kA
Energy limiting class 3
Rated impulse withstand voltage(1.2/50) Uimp (V) 4000
Dielectric test voltage at ind. Freq. for 1 min (kV) 2
Уровень загрязнения 2
Power loss per pole Rated current (A)
1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80
Характеристика термомагнитного разрыва B, C, D 8-12In, 9.6-14.4In

Механические характеристики

Электрическая жизнь 4, 000
Механический срок службы 20, 000
Индикатор положения контакта Да
Степень защиты IP20
Референтная температура для настройки теплового элемента (℃) 30
Ambient temperature (with daily average ≤35℃) -5…+40
Storage temperation (℃) -35…+70
Установка Тип терминального соединения Кабельный/U-образный разделительный щит/Разделительный щит с винтовыми наконечниками
Верхний и нижний размер терминала для кабеля 25mm2  / 18-4 AWG
Высокоскоростной терминал для разветвления кабелей 10mm2  / 18-8 AWG
Усиление крутящего момента 2.5 N*m  /  22 In-Ibs.
Установка На DIN-рейле EN 60715 (35 мм) с помощью устройства с быстрым зажимом
Вставка From top and bottom

Combination
with
accessories

Помощный контакт Да
Отключение шванта Да
При отпускании напряжения Да
Контакты тревоги Да

ГИД ПО ОТБЕРЕЖЕ

Selecting an 18mm 1P+N Miniature Circuit Breaker

Specify the rated current, pole count, trip curve, operating voltage and board connection details when requesting a JCB3-40M quotation from W9 Group.

01

Match current to the circuit

The catalog covers 1–40 A. Confirm the required current step and coordinate it with the circuit conductors and load.

02

Choose the trip curve

The reviewed matching features list B / C. Request the selected time-current curve for starting-current and coordination checks.

03

Specify poles and supply

State the supply voltage and required 1P+N arrangement. Confirm the wiring diagram and terminal allocation.

04

Check the board space

Allow for the listed 18 mm single-module body and confirm terminal and busbar compatibility.

Before specifying JCB3-40M: Confirm the ordered current, pole configuration, operating voltage and trip curve. Use the matching model datasheet for installation and fault-duty checks.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB3-40M MCB Datasheet and DIN Rail Installation Information

Use W9 Group technical support and the product directory to specify JCB3-40M. Request a datasheet and wiring diagram matching the selected JCB3-40M configuration.

Часто задаваемые вопросы покупателей

JCB3-40M MCB FAQs: Current, Trip Curve and Board Fit

Find answers about JCB3-40M selection, configuration and ordering.

What does JCB3-40M protect against?

The product is listed for overload and short-circuit protection. Residual-current protection requires a suitable additional device or an RCBO configuration.

Which currents are listed for JCB3-40M?

The target-model summary lists a 1–40 A range. Confirm the individual current rating and complete order code.

Which pole configurations are offered?

This page lists 1P+N. Confirm the wiring and neutral arrangement in the matching product drawing.

How do I specify the trip curve?

The matching features list B / C. Select using the load starting current and protective coordination, and request the corresponding curve.

Is the listed 6kA rating suitable for every board?

The breaking rating must meet the prospective short-circuit current at the installation point. Confirm the applicable voltage and rating on the supplied datasheet.

How is this MCB installed?

The source lists 35 mm DIN-rail mounting. Confirm the terminal capacity, busbar type, dimensions and tightening instructions for the ordered version.

What is needed for a JCB3-40M quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB3-40M MCB Quotation

Tell W9 Group your rated current, pole count, trip curve, operating voltage and board connection details, quantity and destination market so the selected configuration can be identified.

Свяжитесь с W9 Group