Продукты для защиты от перегрузок

  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 1
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 12
  • JCB3-80H Miniature Circuit Breaker 10kA
  • JCB3-80H Miniature Circuit Breaker 10kA
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 1
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 2
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 3
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 4
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 5
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 6
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 7
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 8
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 9
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 10
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 11
  • Miniature Circuit Breaker JCB3-80H 10kA Gallery image 12
  • JCB3-80H Miniature Circuit Breaker 10kA
  • JCB3-80H Miniature Circuit Breaker 10kA

JCB3-80H Miniature Circuit Breaker

W9 Group lists the JCB3-80H miniature circuit breaker for overload and short-circuit protection. The catalog offers 1–80 A current options, single-pole through four-pole configurations and B, C or D trip curves for distribution circuits. Request the selected configuration and matching technical documents from W9 Group.

ТЕХНИЧЕСКИЕ ДАННЫЕ

JCB3-80H 10kA Miniature Circuit Breaker Specifications

W9 Group lists the JCB3-80H miniature circuit breaker for overload and short-circuit protection. The catalog offers 1–80 A current options, single-pole through four-pole configurations and B, C or D trip curves for distribution circuits.

JCB3-80H product specifications
Product model JCB3-80H
Protection function Overload and short circuit
Catalog current range 1–80 A
Pole options 1P, 2P, 3P, 4P
Trip curves B / C / D
Breaking-capacity options 10 kA; confirm the applicable voltage
Индикатор положения контакта Listed
Standard listed by supplier IEC 60898-1; request applicable documents

ГИД ПО ОТБЕРЕЖЕ

Selecting a 1–80A MCB by Pole Arrangement and B, C or D Curve

Specify the rated current, pole count, trip curve, supply voltage and required breaking capacity when you request a JCB3-80H quotation from W9 Group.

01

Choose the rated current

For JCB3-80H, match the ordered current to the circuit design and conductor protection requirements; the catalog range is 1–80 A.

02

Choose the trip curve

Specify B, C or D and request the corresponding time-current curve to assess starting current and coordination.

03

Match pole count and fault duty

State the number of poles and supply voltage. Confirm that the selected breaking rating meets the prospective short-circuit current.

04

Check mounting and connections

Request the terminal, busbar and mounting drawing for the ordered version before finalizing the distribution board.

Before ordering JCB3-80H: confirm rated current, pole count, trip curve, supply voltage and required breaking capacity, the matching datasheet and the installation drawing.
Область применения продукции по защите цепей W9 Group для OEM и ODM
Базовая линейка устройств защиты от перегрузок W9 Group — иллюстрация категории.

СВЯЗАННЫЕ РЕСУРСЫ

JCB3-80H 10kA MCB Technical Document Requests

Use W9 Group technical support and the product directory to specify JCB3-80H. Request the matching datasheet before ordering.

Часто задаваемые вопросы покупателей

10kA MCB FAQs: Voltage, Trip Curve and Board Fit

Find answers about JCB3-80H selection, configuration and ordering.

What does JCB3-80H protect against?

The supplier lists overload and short-circuit protection. Confirm any separate residual-current protection required by the installation.

Which current options are listed?

W9 Group lists 1–80 A for this model range. Ask for the exact order code and available current steps.

How do I choose the trip curve?

The catalog offers B, C and D. Request the selected curve and check it against the load starting behavior and upstream protection.

What is needed for a JCB3-80H quotation?

Отправьте необходимую конфигурацию, количество, целевой рынок и требования к документации. Попросите компанию W9 Group подтвердить цену, минимальное количество заказа, наличие образцов и срок изготовления выбранной конфигурации.

What pole options are available for JCB3-80H?

The catalog lists 1P, 2P, 3P and 4P configurations. Confirm the pole count, supply voltage and complete order code before ordering.

How should I specify the breaking capacity?

The source lists a 10 kA version for this model. Confirm the applicable voltage, prospective short-circuit current and matching datasheet before ordering.

ЗАЯВКА О ПОКУПКЕ ПРОДУКТА

Request a JCB3-80H 10kA MCB Quotation

Tell W9 Group your rated current, pole count, trip curve, supply voltage and required breaking capacity, quantity and destination market so the selected configuration can be identified.

Свяжитесь с W9 Group