JCB3-80H Miniature Circuit Breaker
The JCB3-80H miniature circuit breaker protects lighting, distribution and equipment circuits against overloads and short circuits. The listed range covers 1–80 A, single-pole through four-pole versions, and B, C or D trip curves. Ask for the voltage-specific datasheet when selecting the 10 kA version.
- 10kA listed breaking capacity
- Overload and short-circuit protection
- Rated current range: 1–80A
- 1P, 2P, 3P and 4P configurations
- B, C and D trip curves
- Contact indicator: green = OFF, red = ON
- 35mm DIN-rail mounting
- IEC 60898-1 standard
PRODUCT OVERVIEW
JCB3-80H MCB for Lighting and Equipment Circuits
The JCB3-80H is used in residential, commercial and industrial distribution systems. It combines overload and short-circuit protection in a DIN-rail device, with a contact indicator for checking the device state.
If the panel needs an auxiliary signal or remote release, specify that function with the breaker. W9 Group can be contacted about the accessory options; compatibility and the control supply need to be checked for the version being ordered.
JCB3-80H Current Limiting, Switching and Auxiliary Contacts
- Current limiting and coordination
- The supplier describes the JCB3-80H as an energy-limiting breaker intended to reduce the energy passed into a fault. Coordination with an upstream breaker depends on the actual device combination; request the coordination data for the proposed installation.
- Contact indication and manual switching
- Green indicates OFF and red indicates ON. Alongside automatic overload and short-circuit interruption, the catalogue lists infrequent manual switching and an isolation function. Check the isolation markings on the supplied version before using it for that purpose.
- Bottom-mounted auxiliary contact
- The supplier describes a bottom-fixing auxiliary contact for status signalling. Include this requirement when ordering so its mounting arrangement can be checked against the panel and the selected breaker.
- Busbars and release accessories
- Cable, pin-type and U-type busbar connections are listed. The accessory range also includes alarm contacts, shunt releases and undervoltage releases; match the accessory and its control supply to the breaker version.
JCB3-80H Applications in Public Buildings and Industry
Application examples in the supplier catalogue include lighting, distribution and equipment circuits in homes, offices, schools, hospitals and airport facilities.
Other catalogue examples include renewable-energy facilities, power stations, petrochemical sites, offshore platforms and steel plants. In these settings, select the breaker for the particular distribution circuit and enclosure. These examples do not establish suitability for hazardous locations or direct connection to a PV DC circuit.
TECHNICAL DATA
JCB3-80H Miniature Circuit Breaker Specifications
The table covers electrical ratings, mounting and terminal details. For a 10 kA order, check the operating voltage and the datasheet for the selected version.
| Standard | IEC/EN 60898-1 | IEC/EN 60947-2 | |
|
Electrical features |
Rated current In (A) |
1, 2, 3, 4, 6, 10, 16,20, 25, 32, 40, 50, 63,80 |
|
| Poles | 1P, 1P+N, 2P, 3P, 3P+N, 4P | 1P, 2P, 3P, 4P | |
| Rated voltage Ue(V) | 230/400~240/415 | ||
| Insulation voltage Ui (V) | 500 | ||
| Rated frequency | 50/60Hz | ||
| Rated breaking capacity | 10 kA | ||
| Energy limiting class | 3 | ||
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 4000 | ||
| Dielectric test voltage at ind. Freq. for 1 min (kV) | 2 | ||
| Pollution degree | 2 | ||
| Power loss per pole | Rated current (A) | ||
| 1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80 | |||
| Thermo-magnetic release characteristic | B, C, D | 8-12In, 9.6-14.4In | |
|
Mechanical features |
Electrical life | 4, 000 | |
| Mechanical life | 20, 000 | ||
| Contact position indicator | Yes | ||
| Protection degree | IP20 | ||
| Reference temperature for setting of thermal element(℃) | 30 | ||
| Ambient temperature (with daily average ≤35℃) | -5…+40 | ||
| Storage temperation (℃) | -35…+70 | ||
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar | |
| Terminal size top/bottom for cable | 25mm2 / 18-4 AWG | ||
| Terminal size top/bottom for Busbar | 10mm2 / 18-8 AWG | ||
| Tightening torque | 2.5 N*m / 22 In-Ibs. | ||
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | ||
| Connection | From top and bottom | ||
|
Combination |
Auxiliary contact | Yes | |
| Shunt release | Yes | ||
| Under voltage release | Yes | ||
| Alarm contact | Yes | ||
PRODUCT DETAILS
JCB3-80H Product Illustrations and Technical Drawings
Original illustrations from the supplier’s product page, including the labels and figures printed on each image. Open an image to read the details at full size.
Product features

Pole configurations

Tripping characteristic curves

Dimensions and DIN-rail profile

SELECTION GUIDE
JCB3-80H MCB Selection: B, C and D Trip Curves
The supplier relates each trip characteristic to the starting-current demand of the load.
B curve for lower-inrush loads
The supplier describes a magnetic tripping range of 3–5 In for B characteristics and lists household distribution and appliance circuits as examples. In is the rated current of the breaker.
C curve for lighting and equipment circuits
The listed C characteristic has a magnetic tripping range of 5–10 In. Application examples include distribution lines, lighting and motor circuits. Compare the actual starting current with the curve before choosing the breaker.
D curve for higher starting current
The listed D characteristic has a magnetic tripping range of 10–20 In. The supplier gives transformers and solenoid valves as examples of loads with higher inrush current. Check the selected curve with the upstream protection and the circuit fault-current conditions.
ABOUT W9 GROUP
Buying JCB3-80H Circuit Breakers from W9 Group
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. Contact W9 Group about JCB3-80H specifications, installation documents or branding requirements for your order.

RELATED RESOURCES
JCB3-80H Datasheets and Technical Support
Need a JCB3-80H datasheet, wiring diagram or trip curve? Contact technical support with the current rating and pole configuration you need. You can also browse the product range and the W9 Group download centre below.
PRODUCT DIRECTORYBrowse W9 Group productsOpen the product directory to see other models and their specifications.
DOCUMENTSVisit the download centreBrowse available documents. If the JCB3-80H file is missing, contact technical support.
BUYER FAQ
JCB3-80H Circuit Breaker FAQs
Answers to common questions about ratings, wiring, installation and ordering.
What protection does the JCB3-80H provide?
It provides overload and short-circuit protection. A separate residual-current device or suitable RCBO is needed where the installation requires earth-leakage protection.
Which current ratings are available?
The listed range is 1–80 A. Ask W9 Group for the product code for your required current rating.
How do I select the trip curve?
B, C and D curves are listed. Compare the load starting current with the selected curve and check coordination with the upstream protection.
Which pole configurations are listed?
The range lists 1P, 2P, 3P and 4P versions. Choose the version for the circuit supply and wiring arrangement.
Does the 10 kA rating apply at every voltage?
Do not assume that it does. Check the operating voltage and test conditions shown on the datasheet for the proposed version.
What should I send for a JCB3-80H quotation?
Send W9 Group your required supply type and voltage, rated current, pole configuration and trip curve, quantity and destination country. Include any wiring, accessory or documentation requirements. Ask for price and delivery time for the proposed version.
PRODUCT ENQUIRY
Get a Quote for JCB3-80H Circuit Breakers
Send W9 Group your required supply type and voltage, rated current, pole configuration and trip curve, quantity and destination country.
Include any wiring, accessory or documentation requirements. Ask for price and delivery time for the proposed version.