W9 Group lists the JCB3-80H miniature circuit breaker for overload and short-circuit protection. The catalog offers 1–80 A current options, single-pole through four-pole configurations and B, C or D trip curves for distribution circuits.
| スタンダード | IEC/EN 60898-1 | IEC/EN 60947-2 | |
|
電気機能 |
定格電流(A) |
1, 2, 3, 4, 6, 10, 16,20, 25, 32, 40, 50, 63,80 |
|
| ポーランド人 | 1P, 1P+N, 2P, 3P, 3P+N, 4P | 1P, 2P, 3P, 4P | |
| 定格電圧 Ue(V) | 230/400~240/415 | ||
| 絶縁電圧 Ui(V) | 500 | ||
| 定格周波数 | 50/60Hz | ||
| 定格断面積 | 10 kA | ||
| Energy limiting class | 3 | ||
| 耐 impulse電圧(1.2/50)Uimp(V) | 4000 | ||
| Dielectric test voltage at ind. Freq. for 1 min (kV) | 2 | ||
| 汚染度 | 2 | ||
| Power loss per pole | Rated current (A) | ||
| 1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80 | |||
| 熱磁性放出特性 | B, C, D | 8-12In, 9.6-14.4In | |
|
機械的特徴 |
電気寿命 | 4, 000 | |
| 機械的寿命 | 20, 000 | ||
| 接触位置インジケーター | はい | ||
| 保護レベル | IP20 | ||
| サーマルエレメントの設定時の基準温度(℃) | 30 | ||
| 周囲温度(日平均値が35℃以下) | -5…+40 | ||
| 保管温度(℃) | -35…+70 | ||
| インストール | ターミナル接続タイプ | ケーブル/U型バスバー/ピン型バスバー | |
| ケーブル用の端末サイズの上部/下部 | 25mm2 / 18-4 AWG | ||
| バスバー用端子サイズの上部/下部 | 10mm2 / 18-8 AWG | ||
| 締めトルク | 2.5 N*m / 22 In-Ibs. | ||
| 取り付け | DINレール用 EN 60715 (35mm) 用、高速クリップ装置による取り付け | ||
| 接続 | From top and bottom | ||
|
Combination |
補助連絡先 | はい | |
| シュントの放出 | はい | ||
| 電圧降下時の放電 | はい | ||
| アラームコンタクト | はい | ||
選定ガイド
Selecting a 1–80A MCB by Pole Arrangement and B, C or D Curve
Specify the rated current, pole count, trip curve, supply voltage and required breaking capacity when you request a JCB3-80H quotation from W9 Group.
Choose the rated current
For JCB3-80H, match the ordered current to the circuit design and conductor protection requirements; the catalog range is 1–80 A.
Choose the trip curve
Specify B, C or D and request the corresponding time-current curve to assess starting current and coordination.
Match pole count and fault duty
State the number of poles and supply voltage. Confirm that the selected breaking rating meets the prospective short-circuit current.
Check mounting and connections
Request the terminal, busbar and mounting drawing for the ordered version before finalizing the distribution board.
W9 GROUPについて
W9 Group 10kA MCB Supply and Support
Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCB3-80H enquiry, contact W9 Group about configuration and matching product documents.

関連リソース
JCB3-80H 10kA MCB Technical Document Requests
Use W9 Group technical support and the product directory to specify JCB3-80H. Request the matching datasheet before ordering.
購入者のよくある質問
10kA MCB FAQs: Voltage, Trip Curve and Board Fit
Find answers about JCB3-80H selection, configuration and ordering.
What does JCB3-80H protect against?
The supplier lists overload and short-circuit protection. Confirm any separate residual-current protection required by the installation.
Which current options are listed?
W9 Group lists 1–80 A for this model range. Ask for the exact order code and available current steps.
How do I choose the trip curve?
The catalog offers B, C and D. Request the selected curve and check it against the load starting behavior and upstream protection.
What is needed for a JCB3-80H quotation?
必要な構成、数量、配送先市場、および書類の要件を送信してください。W9 Groupに、選択した構成の価格、最小注文数量、サンプル、納期を確認していただくよう依頼してください。.
What pole options are available for JCB3-80H?
The catalog lists 1P, 2P, 3P and 4P configurations. Confirm the pole count, supply voltage and complete order code before ordering.
How should I specify the breaking capacity?
The source lists a 10 kA version for this model. Confirm the applicable voltage, prospective short-circuit current and matching datasheet before ordering.
製品のお問い合わせ
Request a JCB3-80H 10kA MCB Quotation
Tell W9 Group your rated current, pole count, trip curve, supply voltage and required breaking capacity, quantity and destination market so the selected configuration can be identified.