JCSD alarm auxiliary contact

The JCSD alarm auxiliary contact is listed by W9 Group for indicating automatic fault tripping of a compatible MCB or RCBO. The accessory uses a 1NO + 1NC contact arrangement and a 9 mm body fitted on the breaker’s left side. Confirm the host code and signal-circuit contact rating before ordering. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

JCSD 1NO 1NC Alarm Auxiliary Contact Specifications

The JCSD alarm auxiliary contact is listed by W9 Group for indicating automatic fault tripping of a compatible MCB or RCBO. The accessory uses a 1NO + 1NC contact arrangement and a 9 mm body fitted on the breaker’s left side. Confirm the host code and signal-circuit contact rating before ordering.

JCSD product specifications
Model JCSD
Category Breaker alarm auxiliary contact
Signal function described Indication after automatic overload / short-circuit tripping
Contact arrangement 1NO + 1NC
Body width 9 mm
Mounting position Left side of compatible host breaker
Host devices described MCB / RCBO; confirm exact compatible codes
Electrical contact rating Confirm the voltage, current and load category for the offered contact

SELECTION GUIDE

Selecting an MCB or RCBO Fault Trip Alarm Contact

Specify the host breaker, alarm logic, signal voltage/current and accessory arrangement when requesting a JCSD quotation from W9 Group.

01

Specify the indication function

State whether the circuit needs fault-trip alarm or ordinary breaker-position indication. Confirm the required signal behavior.

02

Check host compatibility

Provide the exact MCB / RCBO model and any existing side-mounted accessories. Confirm coupling and available space.

03

Match the signal load

Specify signal voltage, current and AC / DC load type. Request the matching contact rating before connecting the circuit.

04

Confirm terminal logic

Request the contact-state diagram and terminal numbering for the 1NO + 1NC arrangement.

Before specifying JCSD: Confirm host compatibility, trip-alarm behavior, terminal numbering and contact rating. Do not use the conflicting source contact-current values as an operating limit.

ABOUT W9 GROUP

W9 Group Alarm Contact Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCSD enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

JCSD Alarm Contact Wiring and Signal Rating Information

Use W9 Group technical support and the product directory to specify JCSD. Request a datasheet and wiring diagram matching the selected JCSD configuration.

BUYER FAQ

JCSD Alarm Auxiliary Contact FAQs: Trip Indication and Host Fit

Find answers about JCSD selection, configuration and ordering.

What does the JCSD alarm contact indicate?

The source describes indication after automatic overload or short-circuit tripping of a compatible host breaker. Confirm the exact contact-state behavior with its wiring diagram.

Is this JCSD a surge protective device?

No. This product page is for an alarm auxiliary contact. Confirm the product category and order code because similar model labels appear elsewhere in the catalog.

What contact arrangement and width are listed?

The source lists 1NO + 1NC contacts and a 9 mm body. Confirm the terminal numbering and mounting clearance.

Does the alarm contact trip the breaker?

It is an indication accessory, not a shunt trip release. Confirm a separate trip accessory if the control circuit must open the breaker.

What voltage and current can its contacts switch?

The page’s low-current prose and higher-current table conflict. Confirm the rated signal voltage, current and load category for the supplied version.

Does JCSD fit every MCB or RCBO?

Compatibility is not universal. Provide the exact host code and confirm the left-side coupling, accessory stacking and terminal diagram with W9 Group.

What is needed for a JCSD quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a JCSD Alarm Auxiliary Contact Quotation

Tell W9 Group your host breaker, alarm logic, signal voltage/current and accessory arrangement, quantity and destination market so the selected configuration can be identified.

Contact W9 Group