Circuit Protection Products

  • MCCB Accessories JCOF Auxiliary Contact Gallery image 1
  • MCCB Accessories JCOF Auxiliary Contact Gallery image 2
  • MCCB Accessories JCOF Auxiliary Contact Gallery image 3
  • MCCB Accessories JCOF Auxiliary Contact Gallery image 1
  • MCCB Accessories JCOF Auxiliary Contact Gallery image 2
  • MCCB Accessories JCOF Auxiliary Contact Gallery image 3

JCOF auxiliary contact

The JCOF auxiliary contact provides mechanically linked breaker-position feedback for control and indication circuits. W9 Group lists a 1NO + 1NC arrangement and a 9 mm body. Confirm the host breaker and contact truth table before specifying this accessory for a panel. Request the selected configuration and matching technical documents from W9 Group.

TECHNICAL DATA

JCOF Auxiliary Contact Specifications and Contact Ratings

The JCOF auxiliary contact provides mechanically linked breaker-position feedback for control and indication circuits. W9 Group lists a 1NO + 1NC arrangement and a 9 mm body. Confirm the host breaker and contact truth table before specifying this accessory for a panel.

JCOF product specifications
Model JCOF
Function Mechanically linked position indication
Contact arrangement 1NO + 1NC; confirm terminal diagram and reference state
Width 9 mm
AC contact ratings 3 A at 415 V AC; 6 A at 240 V AC; 50/60 Hz
DC contact ratings 1 A at 130 V DC; 2 A at 48 V DC; 6 A at 24 V DC
Insulation voltage Ui 500 V
Protection degree IP20
Installation Left side of a compatible MCB / RCBO; confirm exact host model

SELECTION GUIDE

Selecting a 1NO 1NC Auxiliary Contact for Breaker Position Feedback

Specify the host breaker model, required feedback states, control voltage, load type and terminal arrangement when requesting a JCOF quotation from W9 Group.

01

Identify the host breaker

Provide the exact MCB or RCBO code. The product title mentions MCCB accessories, while its fitting description names MCB / RCBO; confirm mechanical compatibility.

02

Define the feedback states

Specify the required open and closed signals, then confirm the terminal truth table. Request a separate fault-trip signal if position feedback alone is insufficient.

03

Match the control load

Use the AC or DC contact rating for the actual voltage. Confirm load category and minimum reliable switching load for the control input.

04

Check panel integration

Allow for the listed 9 mm body and request the host fitting, wiring and terminal instructions.

Before specifying JCOF: Confirm the host breaker, contact diagram, control voltage and switching duty. The product title and host description differ; generic contactor-coil and time-delay prose is not used as JCOF functionality.

ABOUT W9 GROUP

W9 Group Breaker Auxiliary Contact Supply and Support

Zhejiang W9 Group Technology Co., Ltd. supplies low-voltage electrical products. For a JCOF enquiry, contact W9 Group about configuration and matching product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

JCOF Auxiliary Contact Wiring and Host Compatibility Documents

Use technical support and related products to specify JCOF. Request a datasheet and wiring diagram matching the selected JCOF configuration.

BUYER FAQ

JCOF Auxiliary Contact FAQs: Feedback, Ratings and Breaker Fit

Find answers about JCOF selection, configuration and ordering.

What does the JCOF auxiliary contact indicate?

It follows the mechanically linked breaker contacts to provide position feedback. Confirm the signal for each open, closed, tripped and reset state using the supplied wiring diagram.

Is JCOF a fault-only alarm contact?

Do not assume fault-only indication. The source describes position feedback; confirm whether a separate alarm accessory is required for your control logic.

Can JCOF directly switch the main load?

It is an auxiliary control contact rather than the main power path. Confirm the intended control load against its voltage-specific contact rating.

Which AC and DC contact ratings are listed?

The supplier table lists 3 A at 415 V AC and 6 A at 240 V AC, plus 1 A at 130 V DC, 2 A at 48 V DC and 6 A at 24 V DC. Confirm the utilization conditions for the offered part.

Does JCOF fit every MCB, RCBO or MCCB?

No universal compatibility is established. The body describes left-side MCB / RCBO fitting while the title uses MCCB; confirm the exact host accessory list before ordering.

Does the contact trip or remotely close the breaker?

Position feedback does not establish an opening or closing actuator. Confirm any separate release or operating mechanism needed by the control system.

What is needed for a JCOF quotation?

Send the required configuration, quantity, destination market and document requirements. Ask W9 Group to confirm price, minimum order quantity, samples and lead time for the selected configuration.

PRODUCT ENQUIRY

Request a JCOF Auxiliary Contact Quotation

Tell W9 Group your host breaker model, required feedback states, control voltage, load type and terminal arrangement, quantity and destination market so the selected configuration can be identified.

Contact W9 Group